• Title/Summary/Keyword: 면굴절력

Search Result 25, Processing Time 0.033 seconds

Curvature Radius of Equivalent Lens Obtained by Recursive Numerical Solving of Gaussian Equations (재귀적 수치 계산법을 이용한 등가 렌즈의 곡률 계산)

  • Lee, Kyu Haeng
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.275-286
    • /
    • 2022
  • As a first step in the optical design process, we derive a recursive numerical calculation method that can give a solution to the Gaussian equation that the paraxial rays satisfy. Given the refractive power, the angle of incidence to the first principal plane of the lens, the angle of exit to the second principal plane of the lens, and the distance between the principal planes, the radii of curvature of the front and back surfaces of a lens can be obtained by applying the recursive numerical calculation method proposed in this paper according to the thickness of the lens. If a module consists of two or more lenses, the thickness and radius of curvature of each lens can be similarly determined after selecting the distance between the principal planes of the lens under the condition of the design specification while increasing the number of lenses one by one.

The Error and the Graphical Presentation form of the Binocular Vision Findings (양안시기능 검사 값의 오차와 그래프 양식)

  • Yoon, Seok-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.39-48
    • /
    • 2007
  • The stimulus of accommodation A, the stimulus of convergence C and the prism diopter ${\Delta}$ are reviewed and redefined more obviously. How the A and C are managed in the practice are reviewed and summarized. As a result, the common practical process of the binocular vision findings is most suitable in the case of the $l_c=26.67mm$, where the near distance is measured from the test lens to the near target and its value is 40 cm and the average of the P.D equal to 64 mm. The $l_c$ is the distance between the test lens and the center of rotation. Those values were used at calculating the various values in this paper. The error of the stimulus of accommodation values which are evaluated by the practically used formula (5) are calculated. Where the distance between lens and the principle point of eye is 15.07 mm ($=l_H$). The incremental stimulus of convergence values P' caused by the addition prism $P_m$ are evaluated by the recursion computation method. The P' are varied with the $P_m$, the distance $p_c$ between the prism and the center of rotation, the initial convergence value (or inverse target distance) $C_o$ and the refractive index n of the prism material. The recursion computation method and the other formulas are described in detail. In this paper n=1.7 is used. The two factors by which the P' is increased are exist. The one which is major is the property by which the values of convergence whose unit is ${\Delta}$ are not added in the generally way. The other is the that the actual power of the prism is varied with the angle of incidence light. And the P' is decreased remarkably by an increase in the $p_c$ and $C_o$. The $P^{\prime}/P_m$ are calculated and graphed which are varied with the $p_c$ and $C_o$, where the $P_m=20{\Delta}$, P.D=64 mm and n=1.7. The index n dependence of the $P^{\prime}/P_m$ is negligible (refer to fig. 6). The $p_c$ are evaluated at which the P' equal to the $P_m$ for various $P_m$ (refer to table 1). The actual values of the stimulus of convergence and accommodation which are manipulated simply in the practice are calculated. Two graphical forms are suggested. The one is like as the commonly used one. But the stimulus of convergence and of accommodation values in the practice are positioned at the exact positions when the graphic is made (refer to fig. 9). The other is the form that the incremental stimulus of convergence values caused by the addition prisms are represented at actual positions (refer to fig. 11).

  • PDF

Correlation between Anterior and Posterior Corneal Astigmatism in Total Corneal Astigmatism (전체 각막난시에서 전면과 후면 각막난시의 상관성)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.377-382
    • /
    • 2014
  • Purpose: To investigate the effect of anterior, posterior corneal astigmatism and total corneal astigmatism on posterior corneal astigmatism by analyzing correlation. Methods: Participants were 31 patients (31 eyes) without corneal disease at the age range of 22 to 28 who had visited hospital to receive corneal refractive surgery. The total corneal astigmatism and anterior and posterior corneal astigmatism were measured using a rotating scheimpflug camera before surgery. The magnitude of astigmatism was calculated with the difference between the meridian of the steep refractive power and the flat, and With-The-Rule and inverse astigmatism were divided according to the direction of the meridian that was the steepest. Results: The averages of total corneal astigmatism and anterior and posterior astigmatism were found to be $1.13{\pm}0.76D$, $1.51{\pm}0.84D$, and $-0.59{\pm}0.17D$. The magnitude of posterior corneal astigmatism was distributed between -1.0 D and -0.25 D in all the subjects, and when the magnitude of total corneal astigmatism was set as 100, the magnitude of anterior corneal astigmatism was $142.9{\pm}29.9%$. Total corneal astigmatism indicated the highest correlation with the magnitude of anterior astigmatism (y = 0.871x-0.184, $R^2=0.982$) and high negative correlation with posterior astigmatism (y = -2.974x-0.184, $R^2=0.698$). All the subjects' anterior and posterior corneal astigmatism was classified into With-The-Rule. Conclusions: Anterior and posterior corneal astigmatism in the subjects in their 20's showed the magnitude of -3.8 D in 0.2 D and -0.25 D in -1.0 D separately, and both anterior and posterior astigmatism indicated a high percentage of With-The-Rule.

Optical Performance Analysis of the Eye which it Follows in Iris Eccentricity (홍채 편심에 따른 눈의 광학적 성능 분석)

  • Kim, Bong-Hwan;Han, Sun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.31-34
    • /
    • 2009
  • Purpose: We are to analyze optically how to affect the eye related with movement of the iris. Methods: Using the schematic eye to have the crystalline lens of the radial GRIN and the spherical GRIN forms that come to be planned in existing, the iris centre was moved 0.5 mm with nasal direction in order to be identical with the real eye. Also, considering that the iris centre move according to increase of the pupil size, the iris centre was moved 0.4 mm with temporal direction to analyze the optical performance change of the eye respectively. Results: Because of decrease in the spherical aberration, the schematic eye with nasal direction 0.5 mm eccentricity of the iris showed a different consequence plentifully compared with the performance of the real eye. Besides, the schematic eye with temporal direction 0.4 mm eccentricity of the iris showed that the spherical aberration somewhat increased. Conclusions: In case of design of the schematic eye with the similar real eye performance which the iris centre was moved 0.5 mm with nasal direction, we need to research about aspheric coefficient of optical constants of each refracting surface considering the performance change of a spherical aberration, a peripheral power error and astigmatism etc, owing to change of the real eye hence to be affected by the iris movement.

  • PDF

Reflectance and Microhardness Characteristics of Sulfide Minerals from the Sambong Copper Mine (삼봉동광산산(三峰銅鑛山産) 유화광물(硫化鑛物)의 반사도(反射度)와 미경도(微硬度) 특성(特性))

  • Chi, Se Jung
    • Economic and Environmental Geology
    • /
    • v.17 no.2
    • /
    • pp.115-139
    • /
    • 1984
  • The Cu-Pb-Zn-Ag hydrothermal vein-type deposits which comprise the Sambong mine occur within calc-alkaline volcanics of the Cretaceous Gyeongsang Basin. The ore mineralization took place through three distinct stages of quartz (I and II stages) and calcite veins (III stage) which fill the pre-existing fault breccia zones. These stages were separated in time by tectonic fracturing and brecciation events. The reflection variations of one mineral depending on mineralization sequence are considered to be resulted from variation in its chemical composition due to different physico-chemical conditions in the hydrothermal system. The reflection power of sphalerite increases with the content of Fe substituted for Zn. Reflectances of the sphalerite grain are lower on (111) than on (100) surface. The spectral profiles depend on the internal reflection color. Sphalerite, showing green, yellow and reddish brown internal reflection, have the highest reflection power at $544m{\mu}$ (green), $593m{\mu}$ (yellow) and $615m{\mu}$ (red) wavelength, respectively. Chalcopyrite is recognized as biaxial negative from the reflectivity data of randomly oriented grains measured at the most sensitivity at $544m{\mu}$. The microindentation hardness against the Fe content (wt. %) for the sphalerite increases to 8.05% Fe and then decreases toward 9.5% Fe content. Vickers hardness of the sphalerite is considerably higher on surface of (100) than on (111). The relationship between Vickers hardness and crystal orientation of the galena was determined to be $VHN_{(111)}$ > $VHN_{(210)}$ > $VHN_{(100)}$. The softer sulfides have the wider variation of the diagonal length in the indentation. Diagonal length in the indentation is pyrite

  • PDF

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.

A Study on the Surface-Modification of Barium Sulfate/TiO$_2$/Dimethicone Composite Powder and its Application in Color Cosmetics (바륨설페이트/티타늄디옥사이드/디메치콘의 복합화 및 메이크업에서의 응용)

  • Kyung-Ho, Choi;Seung-Yong, Ko;Hak-Hee, Kang;Ok-Sub, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.197-200
    • /
    • 2004
  • Sensor and optical properties have become critical features in powder foundation. The flaky barium sulfate powder shows good smooth texture, adhesion and natural looking characteristics. However, it has limitations abilities in UV shielding, hiding and blooming effect. Thus we adopt TiO$_2$ that has excellent hiding power and blooming effect as well as UV shielding ability, but TiO$_2$ has still intrinsic problems in dispersion and texture. To overcome this disadvantages, the barium sulfate/TiO$_2$/dimethicone composite powder was prepared. The flaky barium sulfate powder was coated with TiO$_2$ in nanoscale and followed by coated with dimethicone. When this surface-modified powder was applied for make-up cosmetics, especially in powder foundation, the powder gave powder foundation more good characteristics than the original flaky barium sulfate, Ti02 powder, dimethicone in abovementioned optical and sensory properties. To characterize the distinctive features of this surface-modified powder, we measured its characteristics with UV in vitro tester, hiding powder test method, goniophotometer, consumer panel test and so on.

Changes in Spherical Aberration and Coma Aberration after Wearing Aspheric Soft Contact Lens in Young Myopes (젊은 성인 근시안에서 비구면 소프트 콘택트렌즈 착용 후 구면수차와 코마수차의 변화)

  • Lim, Dong-Kyu;Kwon, Hyeok;Lee, Koon-Ja
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.469-482
    • /
    • 2018
  • Purpose : We investigated the change of spherical and comma aberrations after wearing aspheric soft contact lens (ASCL) in young myopes. Methods : Fifty young myopes ($23.15{\pm}1.70years$, spherical equivalent: $-2.90{\pm}1.75D$) were recruited and refractive errors were corrected using ASCL (Biotrue, Bausch+Lomb, USA). High order aberrations were measured in the 4 mm pupil size using the wavefront analyze and pupil sizes were measured with a pupillometer at the modes of scotopic condition (light off) at 3.5 m in the 100 lx illuminance condition. Results : Spherical aberrations and coma aberration of the 20s myopes were $0.026{\pm}0.031{\mu}m$ and $0.078{\pm}0.039{\mu}m$ respectively, and $0.019{\pm}0.026{\mu}m$ and $0.082{\pm}0.038{\mu}m$ after ASCL wear that spherical aberration was decreased and coma aberration was increased. However, spherical aberration was decreased in the 68% of the subject have positive spherical aberration, and increased in the 11% of the subject have negative spherical aberration. Coma aberration was increased in the 53% of the subject, did not change in the 19% of the subjects, and decreased in the 28% of the subject. Spherical aberration was not different with the refractive errors in low and moderate myopies, however, coma aberrations was higher in the higher myopes. Conclusion : In a scotopic condition without accommodation stimuli, spherical aberration is decreased after wearing ASCL, however in the subject have negative spherical aberration spherical aberration could be increased, and which is thought to be the influence of contact lens design and pupil size.

Stability Analysis of Nonhomogeneous Slopes by Log -spiral Failure Surface (이질토층사면의 대수누선파양에 대한 안정해석)

  • Kim, Yeong-Su;Seo, In-Seok;Baek, Yeong-Sik
    • Geotechnical Engineering
    • /
    • v.9 no.2
    • /
    • pp.41-54
    • /
    • 1993
  • This paper presents the two and three -dimensional stability analysis of nonhom- ogeneous, c-o soil slopes. Potential failure surface is assumed as a logspiral curve refracted in boundaries of layers. In 3-D analysis, rotational soil mass is assumed with a cylindroid central part terminated with plane ends. Seismic force is considered by sesmic intensity. The program developed in this study is compared with the program PCSTABLS. The ratio of three-dimensional minimum factor of safety to two-dimensional case is examined and factor of safety changes are showed for the ratio of cylindroid length to slope height and numbers of slice. On such bases the following conclusions may by made : (1) The program developed in this program is less conservative than the program PCSTABLS. (2) The value of F2 of this study shows the larger differences than that of PCSTABLS with increasing friction angle (3) Factors of safety computed for 3-D geometry differ considerablely from ordinary 2-D factors of safety. Since Fb/F2 exceeds unity, three -dimensional effects tend to increase the factor of safety. (4) As the ratio of three - dimensional failure width of slope height, b/H increase, the value of Fb/Ff decreases and approaches 1.0 when bye is 14. (5) In calculating the factor of safety using the developed program the number of slices is suitable with the ranges of 30-40

  • PDF

OCULODENTODIGITAL SYNDROME : A CASE REPORT (Oculodentodigital syndrome의 1 증례)

  • Kang, Ho-Seung;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.492-498
    • /
    • 1999
  • Oculodentodigital syndrome(ODD) was first reported by Lohmann in 1920 and termed by Meyer Schwicketath, which they called "dysplasia oculo-dento-digitalis" in 1957. It is somewhat rare heritable disease. ODD is generally inherited in an autosomal dominant pattern with a complex phenotype. The characteristic features are : (1) unique facial features, (2) microphthalmos, (3) syndactyly and camptodactyly of 4th and 5th fingers, (4) osseous anomalies of the middle phalanges of 5th fingers and toes, (5) enamel hypoplasia, (6) dry lusterless hair. We found several occlusal wearing and yellow discoloration of succedaneous teeth, multiple caries lesions, premature loss and pulpal involvement of primary teeth with associated enamel abnormalities caused by generalized enamel hypoplasia in a fairly constant oral finding. Occasionally partial anodontia, microdontia and cleft lip and palate can be manifested. This case, a 9-year-old female with repaired bilateral syndactyly was referred to pediatric dental clinic, Pusan National University Hospital for evaluation of severe attrition of teeth and caries lesions. She had most of the above mentioned typical manifestations of the syndrome. Dental treatment including caries control, stainless steel crown were performed.

  • PDF