• 제목/요약/키워드: 메탈 램프

검색결과 110건 처리시간 0.032초

HID 램프를 위한 전자식 안정기의 LCC 공진 인버터의 최적 설계 (An Optimal Design of LCC Resonant Inverter for Electronic Ballast to Drive HID Lamp)

  • 박종연;장목순;임병노
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.531-537
    • /
    • 2007
  • This paper presents a new method for determining L, Cs, and Cp in a series parallel resonant inverter. This inverter is suitable for driving high-intensity discharge (HID) lamps. The operating frequency is selected to avoid acoustic resonances which are governed by the size and shape of the arc tube. L, Cs and Cp, are chosen to satisfy the ignition and steady state requirements of the lamp. Equations are developed to analyze the starting condition and steady state operating condition of the lamp. For the prototype ballast for a 250W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

메탈 할라이드 램프용 전자식 안정기에 관한 연구 (Study on Electronic Ballast for Metal Hallide Lamps)

  • 오병석;정화진;지철근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.16-21
    • /
    • 1992
  • Incandescent lamps and discharge lamps are generally used as light sources and special ballasts are needed thor stable operation of discharge lamps. In this paper, the author proposes the electronic ballast thor metal hallide lamps, experiments with high frequency square wave of frequency 22.52 KHz to avoid the acoustic resonance phenomenon and proves the usefulness of the proposed ballast. Furthermore, the author uses 220 AC voltage as a input voltage source of the proposed ballast. By examining the proposed ballast, lamp voltage of 139 V(max.) and lamp current of 1.4 A(max) can be measured. Furthermore, stable operation antral great luminouse fluxes are recognized.

  • PDF

메탈 핼라이드 램프용 전자식 안정기 (Electronics ballast for Metal halide lamp)

  • 박재욱;남승식;원재선;신우철;김동희;안항목
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.385-390
    • /
    • 2004
  • In this paper, electronics ballast using double resonant inverter for 250[W] MHD lamp is designed and implemented. Electronics ballast reduce a turn -on/offf loss by using ZVS(Zero Voltage Switching) technic in the double resonant inverter, and when circuit have a analysis, the characteristic evaluations is described generally by using the normalized parameters used numerical analysis. We conform a rightfulness of theoretical analysis by comparing theoretical waveforms and Pspice waveforms and experimental waveforms, double resonant inverter for 250[W] MHD lamp is operated safely.

  • PDF

메탈핼라이드 램프의 프로그램된 이그니션 방식 연구 (A Stuty of Programmed Ignition Method for Metal Halide Lamp)

  • 한수빈;박석인;송유진;정학근;정봉만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.181-183
    • /
    • 2009
  • This paper proposes a programmed ignition method of high frequency electronic ballast for metal halide lamp. The method precisely controls the ignition voltage and prevents possible damage of ballast for abnormal lamp operation or lamp failure, also sures the zero voltage switching. This improved performance for igniting the lamp enables reliable product of high frequency ballast because of high efficiency, fast start and no extra ignitor.

  • PDF

LED 접합온도 추정 방법 및 온도 보상 시스템 (The estimation method of LED junction temperature and temperature compensation system)

  • 박종연;최영민;유진완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2003.1-2004
    • /
    • 2011
  • LED는 친환경 광원으로써 메탈램프에 비해 높은 광 변환 효율과 긴 수명을 갖고 있어 차세대 광원으로 널리 쓰이고 있다. 그러나 이러한 특성은 LED의 접합온도가 일정하게 유지 되어야 가능하다. 실제 LED는 PN접합으로 구성되어 접합온도가 상승될 경우 광 변환 효율의 저하, 색온도의 변화, 사용 수명의 감축을 야기 시키는 요소로 작용한다. 따라서 LED는 방열설계가 중요하며 방열설계가 제대로 되지 못한 경우에 대해서는 온도보상이 필요하다. 본 논문은 LED모듈에 접합온도를 LED업체에서 제공하는 그래프를 이용하여 간접적으로 추정하고 LED의 접합온도를 일정하게 유지 시키는 시스템을 제안하였다.

  • PDF

구동방법에 따른 세라믹 메탈 할라이드 램프의 전기적 및 방전특성 분석 (Electrical and Discharge Charcteristics Analysis of Ceramic Metal Halide Lamp with Operating Method)

  • 장혁진;양종경;김남군;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1623_1624
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp’s properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF

세라믹 메탈할라이드 램프의 전자석 안정기에 따른 전기적 및 광학적 특성에 관한 연구 (Electrical and optical characteristics of Ceramic metal halide lamp with electronic ballast)

  • 장혁진;김남군;이주호;양종경;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.159-160
    • /
    • 2008
  • In recent, ceramic metal halide lamps that use the ceramic in arc tube material have the advantage of high rendering index, high efficacy, long life. According to increase applications, the research continue to improve various factor that is arc tube material, optimization of gas and metal halide. In oder to improve system characteristics of CMH Lamp with ceramic arc tube, when operating CMH lamp with magnetic and electronics ballast, we compared with electrical, optical characteristics in this paper.

  • PDF

메탈할라이드 램프 안정기의 디지털 제어기 개발 (Development of A Digital Controller for The Metal Halide Lamp Ballast)

  • 문태환;김희준;조규민;김명구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1113-1116
    • /
    • 2001
  • This paper presents a digital controller of electronic ballast for the metal halide lamp. The proposed controller includes the control algorithm for soft starting, no load protection, overcurrent protection and dimming(or power control). The proposed controller, moreover, has the high frequency modulation scheme and the tracking algorithm to avoid acoustic resonance phenomena. For the math production with the low cost using the ASICs, the proposed controller has been designed with the EPLDs only, without any microprocessor. In this paper, the proposed control algorithms are described and the experimental results of prototype 150W metal halide electronic ballast are presented.

  • PDF

세라믹 MHL의 컨덕턴스 모델을 이용한 전자식 안정기 설계 (Electronic Ballast Design for Ceramic MHL by using Its Conductance Model)

  • 박종연;신동석
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.117-122
    • /
    • 2008
  • This paper presents the conductance model at high frequency of the Ceramic Metal Halide Lamp and the designing method of the electronic ballast with the LCC resonant tank type by using that model. Conductance model is based on a physical phenomenon in the discharge tube of the lamp and model constants of conductance model are obtained by Least Squares Method. After equivalent impedances are determined by the conductance model, The LCC resonance tank is designed by using the equation of the lamp power. Simulation result using PSpice software and experimental results show that the conductance model in this paper is very useful to design the electronic ballast at high frequency for the Ceramic Metal Halide Lamps.

  • PDF

메탈핼라이드 램프용 고효율 전자식 안정기에 관한 연구 (A Study on High Efficiency Electronic Ballast for Metal Halide Discharge Lamps)

  • 김해준;원재선;박재욱;서철식;이성희;심광열;김종해;김동희
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2157-2165
    • /
    • 2007
  • A novel design technology for a high frequency electronic ballast for metal-halide discharge lamps is proposed. A PFC technique is adopted to get unit power factor and output frequency alteration technique is adopted to avoid acoustic resonance. For characteristics evaluation, the designed electronic ballast is presented using normalized parameter. To reduce losses of the ballast. ZVS control technique is adopted and the maximum flux density of magnetic core for inductor should be kept lower. The electronic ballast for 250[W] metal-halide discharge lamp is implemented and 96[%] efficiency and low conducted EMI level are accomplished.