• Title/Summary/Keyword: 멀티렌즈

Search Result 48, Processing Time 0.027 seconds

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.

A Study of Extraction of Three-dimensional Spatial Information Utilizing the Parallax Error of a Multilens Smartphone Camera (멀티렌즈 스마트폰 카메라의 시차현상을 활용한 3차원 공간정보 획득 연구)

  • Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.1
    • /
    • pp.22-28
    • /
    • 2021
  • We try to extract three-dimensional information, such as the distance from a camera and the actual width and height of an object, from still photographs by a multilens smartphone camera, by means of parallax error. To obtain this information, we develop several formulas and design a method for experimental instrumentation. If the results from this paper were included in algorithms of multilens smartphone cameras, there would be various kinds of applications, such as in the workplace of architectural and civil engineering to obtain an actual dimension, or on a golf course to measure how far away a pin flag is. We expect many more applications of this study, because the multilens smartphone camera is already an important necessity of life.

멀티롤 랜턴의 LED 배열에 따른 배광특성 분석

  • Han, Ju-Seop;Kim, Jong-Uk;Yu, Yong-Su;Gang, Seong-Bok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.395-397
    • /
    • 2013
  • 항로표지는 해상에서 선박의 안전한 항행에 필수적인 요소이며, 현재는 LED를 광원으로 사용하는 등명기를 개발 및 사용하고 있다. LED 멀티롤 랜턴을 개발하여 항로표지의 표체조명, 교량표지, 방파제 표시등 등으로 개발하고하는 연구가 진행되고 있다. 이를 위하여 LED 멀티롤 랜턴의 내부 LED 배치에 따른 배광특성을 분석하였다. 본 논문에서 멀티롤 랜턴은 아크릴 환봉과 설치를 위한 금속재로 구성하였으며, 내부에 LED를 2열로 배치하였다. 최적의 설계를 위하여 아크릴 환봉을 투명한 것과 유백색인 것으로 구분하고 2열의 LED 모듈에 집광렌즈($45^{\circ}$, $60^{\circ}$, 미설치)에 따른 배광특성을 분석하였다. $60^{\circ}$ 집광렌즈를 사용한 경우의 시인효과가 우수하여 이를 바탕으로 LED 멀티롤 랜턴을 최종적으로 설계하였다. 투명 아크릴 환봉에 2열의 LED를 배치하고, $60^{\circ}$ 집광렌즈를 사용한 평판형 및 v형의 2종과 집광렌즈를 사용하지 않은 v형 1종으로 선정하고, 녹색과 홍색으로 제작하여 LED의 배열에 따른 배광특성을 본석하였다.

  • PDF

Changes of Thin Film Coating on Polymer Lenses with Varying Temperature (온도에 의한 고분자 렌즈의 재질별 코팅 박막의 변화)

  • Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: To observe changes of coatings and lens materials with varying temperature to understand effect of temperature on plastic lens. Methods: In this study, three lenses of different refractive indices (2 of thiourethane oriented lenses, an allyl diglycol carbonate oriented lens) were exposed to high temperature (50, 80, and 100 degree) for 5 hours and changes of individual coating (anti-refractive coating, hard coating, and water repellent coating) were measured. Results: As a result, high-refractive index lenses did not exhibit significant variation of hardness. However, hardness of mid-refractive index lens were decreased when exposed to high temperature and destructions of hard coating layer was inferred. Surface contact angles of lens were decreased with increasing temperature and water repellent coating layer were damaged at higher than 80 degree. Conclusions: Multi including water repellent coatings on all three lenses with different refractive indices were damaged when exposed to at or higher than 80 degree. The degree of changes in mechanical and physical properties were depended on polymer material type.

Comparison of Accommodative Function of Young Adults in their Twenties Wearing Monovision, Modified Monovision and Multifocal Soft Contact Lenses (모노비전, 변형된 모노비전, 멀티포컬 콘택트렌즈로 교정 시 20대 성인의 조절기능 비교)

  • Lee, A-Young;Kim, Jeong-Mee;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.117-124
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accommodative function of young adult in their 20s wearing monovision, modified monovision, and aspheric multifocal contact lenses at near task. Methods: Thirty young adults ($23.53{\pm}2.37years$) were fitted with monovision, modified monovision (the application of single vision contact lenses and center-near low addition aspheric multifocal contact lenses), and aspheric center-near multifocal contact lenses. After wearing these modalities during a week for adaption, and after watching visual display at computer for inducing accommodative pressure for 1 hour. The following assessments of accommodative function were made: contrast visual acuity (VA) at distance and near; accommodative response; near accommodative facility; and negative relative accommodation (NRA)/positive relative accommodation (PRA). All measurements were carried out binocularly. Results: In binocular distance VA with contrast of 10%, monovision was the worst among the four modalities (p=0.005). In accommodative response at 1 m (1.00 D), monovision was the lowest (p<0.05) and accommodative response at 40 cm (2.50 D) with monovision was lower than that of modified monovision and multifocal contact lens (p<0.05). We also found that there were no significant differences in accommodative facility and NRA/PRA among the four modalities. Conclusions: In young adult (20s), monovision with low add reduced the accommodative response at near task, however, modified monovision and multifocal lens with center-near type did not affect accommodative relaxation.

Minimization of Gap in LCD Multimedia Screen Using Binary Fresnel Lens (바이너리 프레넬 렌즈를 이용한 LCD 멀티미디어 스크린의 갭 최소화)

  • Jeong, Man-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • LCD multimedia system is necessary to display and transfer the effective image informations. However, this system uses several LCD screens, so the problem of gap between the LCD screens occurs. In order to solve this problem, this paper presents a method of using binary Fresnel lens. This kind of binary fresnel lens makes each screen enlarge and minimize the gap. The optimization of design parameters of binary Fresnel lens is presented.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

뜨겁게 달아오르는 모바일기기용 렌즈 및 모듈시장 동향 - '움직이는 마켓'을 잡아라

  • 한국광학기기협회
    • The Optical Journal
    • /
    • v.13 no.5 s.75
    • /
    • pp.13-19
    • /
    • 2001
  • 최근 IMT-2000과 같은 휴대폰 및 개인휴대단말기(PDA) 등 모바일기기에 큰 관심이 모아지고 있다. 저전압소비의 이들 기기로 사진, 동영상, 음성 등 멀티미디어환경이 지원되기 때문인데, 이에 들어가는 첨단 광학렌즈 및 모듈, 소형 탈 부탁 PC카메라 등도 잇달아 개발돼 9월부터 본격 신제품 출시를 앞두고 있으며 미국, 일본, 유럽 등에 시장 진출도 서두르고 있어 귀추가 주목되고 있다.

  • PDF

Designing the Optical Structure of a Multiscale Gigapixel Camera (멀티스케일방식의 기가픽셀카메라의 광학구조설계)

  • Moon, Hee jun;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.1
    • /
    • pp.25-31
    • /
    • 2016
  • We derive 28 optical structural equations based on our two previous theoretical and experimental papers about a gigapixel camera, which were published in 2013 and 2015 respectively. Utilizing these 28 equations, we are able to obtain an integrated understanding of optical structure for a multiscale gigapixel camera system, in addition to obtaining numerical values for structural parameters very directly and easily.