• Title/Summary/Keyword: 매식

Search Result 230, Processing Time 0.029 seconds

Wettability of titanium implants depending upon surface properties (타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구)

  • Han, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.12-20
    • /
    • 2009
  • Statement of problem: When an implant is fixed, a fixture comes into contact with a tissue fluid. Adhesion of a tissue fluid to a surface of implant is various case by case. Purpose: The ultimate goal of this work is to analyze a correlation between a surface roughness and wettability of implant specimens. A measurement for wettability is performed considering 4 types of specimen implant with surface treatments different from each other to investigate the change of wettability with the elapse of time. Material and methods: Firstly, 20 specimens of titanium were prepared. The specimen were made of a commercial Titanium Grade IV with the diameter of 10 mm and the thickness of 1 mm. According to the method of surface treatment, the specimens were classified into 4 groups of 5 specimens per group. Group A: Machined Surface Group B: Anodized surface Group C: RBM (HA blasting) surface Group D: CMP (calcium methaphosphate) coating surface. Surface roughness of specimen was measured using SV-3000S4 (Mituyoto, Japan). The measurement was based on the standard of JIS1994. Sessile drop method was used to measure the wettability, which measures contact angle between implant disc and saline with the time interval of 5, 10, and 15 seconds. SPSS 11.0 was used to analyze the collected data. In order to analyze the difference of wettability and surface roughness according to implant surface treatment method. The statistical significance was tested with the confidence level of 95%. Pearson's correlation coefficient was used to evaluate the correlation of surface roughness and wettability. Results: The difference of surface roughness was statistically significant in the order of Group C ($1.69{\pm}0.26$), Group D ($1.58{\pm}0.16$), Group B ($0.78{\pm}0.14$) Group A ($0.18{\pm}0.05$). The wettability has also a statistically significant difference, which was in the order of group B ($17.70{\pm}2.66$), Group C ($27.86{\pm}4.52$), Group D ($66.28{\pm}3.70$) Group A ($70.52{\pm}8.00$). There was no difference in wettability with the passage of time. Conclusions: 1. The surface roughness was high in the order of RBM, CMP, Anodized, Machined group (P<.05). 2. The wettability was high in the order of Anodized, RBM, CMP, Machined group (P<.05). 3. There was no statistical significance in the correlation of surface roughness and wettability.

A Survey of College Students Opinions on School Cafeteria in Northern Kyungkido Area (경기 북부 지역 대학생들의 학교식당 이용실태)

  • 황윤경;이지호;김수희
    • The Korean Journal of Food And Nutrition
    • /
    • v.10 no.2
    • /
    • pp.201-207
    • /
    • 1997
  • This survey was based on the college students opinions on their cafeteria in northern Kyungkido area during three weeks(5th Nov.∼21st Nov., 1996). The rate of the daily usage of the college cafeteria was 64.29% in day time class, 44.35% in night time class. The first reason of using the college cafeteria was 'no other place to eat' in day time class(49.38%) and night time class(68.01%). The second reason was 'to be economical' and the third was 'to save the time'. The main reason for not using the college cafeteria was 'bad taste' in day time class(52.09%) and night time class(31.99%). The percentage of the students who ate outside of the college in day time class was 68.63% and night time class was 37.37, 31.18% of the night time class ate the dinner at home after school. The average type of the meal were : the boiled rice, noodles, cookies and bread(from the most to the least). The students survey showed rather dissatisfactory response on taste, preference, the number of the side dishes except the quantity of the food. The necessary improvements for the college cafeteria were, first, 'improve the quality and taste of the food' and 'increase the variety of the menu', 'lower the price' and 'sanitation' were followed.

  • PDF

Histologic Study Of Different Bioceramic Implants In Intrabony Defects (골내낭에 매식된 수종의 생체요법재료에 대한 조직학적 연구)

  • Lee, Chul-Woo;Choi, Sang-Mook;Han, Soo-Boo;Park, Sang-Hyun;Kim, Hyeon-Jong
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.27-46
    • /
    • 1996
  • The purpose of this study was designed to compare with the effects of 4 different surface active bioceramics on the healing process of alveolar bone defects in dogs. Artificial alveolar bone defects depth 4-6mm, width 3-4mm) were created with # 6 round bur at interproximal areas of maxillary canine, maxillary 2nd premolar, mandibular canine, and mandibular 3rd premolar. porous hydroxyapatite(Interpore $200^R$) , 45S5 bioglass, CJ4/lOC crystalline glass, and JJ crystalline glass were implanted in intrabony defects randomly. Experimental groups were divided into 4 categories according to its implant material. After implantation, all groups were examined postoperatively 4 weeks to 12 weeks. 3 dogs was selected randomly and sacrificed after vascular perfusion with 2.5% glutaraldehyde at every 4 weeks. Tissue blocks with surroundig alveolar bone and soft tissues were removed and immersed in formaldehyde/glutaraldehyde fixative. After 20 weeks decalcification with EDTA and formic acid, sections were made and observed under light microscope and transmission electron microscope. In all experimental groups, the encapsulation of inactive connective tissue was observed around graft particles in 4 weeks. As time elapsed, the thickness of surrounding connective tissue was decreased. Osteoconductive bone growth pattern was seen apparently in all groups. CJ4/lOC crystalline glass showed the most active bone formation until 8 weeks. 45S5 bioglass was, however, the most active in new bone formation at 12 weeks. Though there was difference in resorption rate among grafting materials, the size of graft particles was decreased gradually. 45S5 bioglass was resorbed faster than the others. On the other hand, porous hydroxyapatite was degraded most slowly. Phagocytosed particulate matters was observed in the cytoplasm of multinuclear multinuclear giant cell and macrophage under transmission electron microscope. The results suggested suggested that 45S5 bioglass and CJ4/lOC crystalline glass may have some enhanced reparative potential when compared to porous hydroxapatite in the treatment of periodontal defeds. JJ crystalline glass reguires a further investigation of the safety of its use.

  • PDF

Retrospective Study of GS II Implant(Osstem) with an Internal Connection with Microthreads (Micro thread를 포함한 GSII RBM임플란트(Osstem)의 후향적 임상연구)

  • Chee, Young-Deok;Lee, Jae-Hwan;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.417-429
    • /
    • 2009
  • Since the introduction of the concept of osseointegration in dental implants, high long-term success rates have been achieved and accepted as viable option for the treatment of fully and partially edentulous patients. Although the use of domestic implants have increased dramatically, there are few studies on domestic implants with clinical and objective long-term data. 96 endosseous implants placed in 31 patients at Wonkwang University Sanbon Dental Hospital were examined to determine the effect of various factors on implant survival rate and marginal bone loss, through clinical and radiographic results. The design of endosseous implant used to this study is straight with the microthread.(GS II RBM Fixture) 1. 3 fixtures were lost, resulting in 96.9% cumulative survival rate. 2. Survival rate in fifties was significantly lower (93.6%) and no significant difference in marginal bone loss was found according to gender. 3. Survival rates were 95.6% in the maxillary molar area and 97.3% in the mandible molar area. 4. No significant difference in survival rate was found according to presence of bone grafts, type of prostheses, implant position, and length and diameter of implant. 5. A factor influencing marginal bone loss was presence of type of prostheses, while facters such a length, diameter of fixture and bone grafts had no statistically significant effect on crestal bone loss. This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

TISSUE CHANGE AFTER EMBEDDING GELATIN MATRIX IMPLANT(FFIBREL®) IN SUBCUTANEOUS TISSUE OF RATS;HISTOLOGIC, IMMUNOHISTOCHEMICAL AND SCANNING ELECTRON MICROSCOPIC STUDY (백서의 피하조직에 Gelatin Matrix Implant (Fibrel®) 매식시 조직변화에 관한 연구)

  • Kim, Hong-Jin;Lee, Chong-Heon;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.20 no.4
    • /
    • pp.341-354
    • /
    • 1998
  • GMI (Fibrel${(R)}$) is one of the dermal filling substances which have been successfully used for the treatment of depressed cutaneous scar and wrinkles. It's major components are; Gelatin powder, which provides a framework for the clot to form and remains stable under the scar, and ${\varepsilon}$-aminocaproic acid, which inhibits the production of fibrinolysin, and Plasma, which provides the necessary ingredients for collagen synthesis. GMI has advantages of low immunogenicity and increased longevity. It has been known to induce fibroblast activity and promote new collagen synthesis. We used 34 Sprague-Dawley rats which were bred under the same condition and duration. 18 of experimental animals were undergone cardiac puncture, and their blood were collected, centrifugated, and stored in freezer. Out of 16 animals, control group were injected with 2ml plasma into the subcutaneous tissue of Lt. scapular, while experimental group were implanted of 2 ml GMI into the Rt. same area. Experimental animals were sacrificed at the 3rd day, 5th day, 1st week and 2nd week respectively after implantation of GMI. To observe the histopathologic change of GMI and surrounding tissue reaction of GMI, we had examined with H&E staining, immunohistochemical staining with vimentin, ${\alpha}$-SMA, S-100 under LM and SEM. The obtained results were as follows ; 1. In LM study, the inflammatory cell infiltrations and granulation tissue formation were observed, and muscle tissues were well attached with adipose tissues in the control group. In the experimental group, inflammatory cell infiltrations had been observed by the 2nd week and irregular adipiose tissues and well differentiated mesenchymal tissues were examined. 2. In immunohistochemical study, the experimental group of ${\alpha}$-SMA study, there were a prominent positive response on endothelial development of granulation tissues and mesenchymal tissues compare with the control group. In vimentin study, positive response on mescenchymal fibroblast continued to 2nd week, but negative in the control group. In S-100 study, both groups were positively responded on irregular adipose tissues. 3. In SEM study, collagen fibers were embedded by the plasma by the 5th day in the control group, and in the 3rd day experiment GMI were resorved but communited with collagen fiber till the 1st week. Collagen fibers were infilt-rated into GMI at the 2nd week and the infilltrated GMI were conglomerated with the mature adipose cells and the collagen fibers. From the above results, GMI implantation in the subcutaneous tissue of Sprague-Dawley rat, the mild infiltration of inflammatory cells were showed till 2nd week and the granulation tissues were observed. GMI were nearly resorbed till 2nd week, but well attached with adipose tissue and collagen fibers. The endothelium and fibroblasts were actively proliferated. Adipose tissues and mesenchymal tissue cells were observed. As already expressed, GMI showed resorptive change in course of time without any early immune reaction, and seemed to induce fibroblast activity and promote new collagen synthesis.

  • PDF

A BIOLOGIC STUDY ON TOOTHASH - PLASTER OF PARIS MIXTURE WITH ABSORBABLE COLLAGEN MEMBRANE IN THE TREATMENT OF PERI-IMPLANT DEFECTS (임플란트 주위염 치료시 치아회분말과 치과용 연석고의 혼합 매식의 골재생 효과)

  • Choi, Hee-Yeon;Kim, Hak-Kyun;Kim, Su-Gwan;Moon, Seong-Yong;Kim, Sang-Yeol;Park, Kwang-Bum;Kim, Young-Min;Lim, Seong-Chul;Kim, Eun-Seok;Lee, Jeong-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.142-149
    • /
    • 2008
  • The purpose of this study was to evaluate histomorphometrically a toothash - plaster of Paris mixture associated with collagen membrane ($Bio-Gide^{(R)}$), regarding new bone formation in the peri-implantitis defects in dogs. Three mandibular molars were removed from 1-year-old mongrel dogs. After 2 months of healing, 2 titanium implants with sandblasted with large grit and acid etched (SLA) surface were installed in each side of the mandible. Experimental peri-implantitis was induced with ligatures after successful osseointegration. Ligatures were removed after identification of bone defect beneath the level of 5th thread of fixture on radiographic image. The mucoperiosteal flaps were elevated and the contaminated fixtures were treated with chlorhexidine and saline. The bone defects were assigned to one of the following treatments: no guided bone regeneration (GBR) procedure (group 1), GBR with Bio-$Oss^{(R)}$ and Bio-$Gide^{(R)}$ (group 2), or GBR with toothash - plaster of Paris mixture (TPM) and Bio-$Gide^{(R)}$ (group 3). The dogs were sacrificed after 8 or 16 months. The mean percentages of new bone formation within the limits of the 5 most coronal threads were $17.83{\pm}10.69$ (8 weeks) and $20.13{\pm}13.65$ (16 weeks) in group 1, $34.25{\pm}13.32$ (8 weeks) and $36.33{\pm}14.21$ (16 weeks) in group 2, and $46.33{\pm}18.39$ (8 weeks) and $48.00{\pm}17.78$ (16 weeks) in group 3, respectively. The present study confirmed statistically considerable new bone formation within the threads in group 3 compared with group 1 at 8 and 16 weeks (P<0.05). Although, data analysis did not reveal significant differences between group 2 and 3, the latter showed better results during the period of 8 or 16 weeks. Our findings support the effectiveness of TPM as a GBR material in the treatment of peri-implantitis bone defect.

A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.) (Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.677-685
    • /
    • 2000
  • Anchorage plays an important role in orthodontic treatment. Because of limited anchorage Potential and acceptance problems of intra- or extraoral anchorage aids, endosseous implants have been suggested and used. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period for osseointegration. Titanium miniscrews and microscrews were introduced as orthodontic anchorage due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and their ability to be placed in any area of the alveolar bone. In this study, a skeletal Class II Patient was treated with sliding mechanics using M.I.A.(micro-implant anchorage). The maxillary micro-implants provide anchorage for retraction of the upper anterior teeth. The mandibular micro-implants induced uprighting and intrusion of the lower molars. The upward and forward movement of the chin followed. This resulted in an increase of the SNB angle, and a decrease of the ANB angle. The micro-implants remained firm and stable throughout treatment. This new approach to the treatment of skeletal Class II malocclusion has the following characteristics . Independent of Patient cooperation. . Shorter treatment time due to the simultaneous retraction of the six anterior teeth . Early change of facial Profile motivating greater cooperation from patients These results indicate that the M.I.A. can be used as anchorage for orthodontic treatment. The use of M.I.A. with sliding mechanics in the treatment of skeletal Class II malocclusion increases the treatment simplicity and efficiency.

  • PDF

Effect of low intensity pulsed ultrasound (LIPUS) on bone healing around a titanium implant in the tibia of osteoporosis-induced rats (골다공증 유도 백서경골에 티타늄 임플란트 매식 시 저출력 초음파 적용이 골 치유에 미치는 영향)

  • Hwang, Young-Seob;Jeon, Hyun-Jun;Shin, Sang-Hun;Chung, In-Kyo;Kim, Gyoo-Cheon;Kim, Chul-Hoon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.386-395
    • /
    • 2011
  • Introduction: Osteoporosis is a major health problem in the elderly that involves changes in the properties of bone as well as impaired bone healing around a titanium implant in both humans and animals. This study examined effect of low intensity pulsed ultrasound (LIPUS) on the bone healing process around a titanium implant in osteoporosis-induced rats. Materials and Methods: Sixteen rats were divided into two groups. A control group with osteoporosis induced by removing both ovaries and an experimental group of rats that were applied with LIPUS after osteoporosis had been induced. A screw type titanium implant (diameter, 2.0 mm: length, 3.5 mm, Cowell-Medi, KOREA) was placed into the tibias of 16 rats. The control and experimental group contained 8 rats each. The rats were sacrificed at 1, 2, 4, and 8 weeks after implantation to examine the histopathology and immunochemistry. Results: The histopathology examination revealed earlier new bone formation in the experimental group than the control group. In particular, at 1 week after implantation, more new bone matrix and collagen were observed around the implant of the experimental group compared to the control group. Immunochemistry analysis showed that the level of OPG expression of the experimental group was higher in the early stages than in the control group. After 8 weeks, the levels of OPG expression were similar in both groups. The expression level of receptor activator of nuclear factor kB ligand (RANKL) was stronger in the experimental group than the control group. After 4 weeks, the level of RANKL expression was similar in both groups. Conclusion: These results suggest that the application of LIPUS to implantation can promote bone healing around titanium in osteoporosis animals.

EVALUATION OF THE INTERFACES BETWEEN IMPLANTS AND REGENERATED BONE USING BONE MORPHOGENETIC PROTEIN AND DEMINERALIZED FREEZE-DRIED BONE (임플란트 매식시 골형성단백질 및 탈회동종골 사용에 따른 골재생 및 계면에 대한 연구)

  • Kang, Sang-Gyu;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.24-39
    • /
    • 2000
  • Various methods and graft materials have been used to fill in the defect adjacent to the implants and considered as clinically acceptable. But it is not clear whether the regenerated bone increases the implant-bone contact and supports the implant. The purpose of this study is to evaluate regenerated bone surrounding implants using bone morphogenetic protein(BMP) and demineralized freeze-dried bone(DFDB), and the interfaces between implants and regenerated bone. bBMP was extracted and partially purified from the bovine bone matrix using heparine chromatography. Demineralized freeze-dried bone was made from the dog. Inactive insoluble collagenous bone matrix(IBM) of dog was used as carrier of bBMP. Interfaces of titanium coated epoxy resin implants were processed for demineralized section for transmission electron microscopy(TEM) and those of screw type implants were for nondemineralized section for light and fluoromicroscopic examination. Implants were inserted in the inferior border of mandible of adult dogs and artificial bony defects($3{\times}3{\times}4mm$) were made at the mesial and distal side of implants. Defects were filled with BMP(BMP group) and DFDB(DFDB group). For the fluoromicroscopic examination, the fluorescent dyes(oxytetracycline, calcein green, alizarin red) were injected 2, 4, 6, 8, 12 weeks after implantation. The experimental animals were sacrificed at the 6th and the 12th week and their mandible were extirpated and processed for examination with light microscopy, fluoromicroscopy and TEM. The obtained results were as follows : 1. By the light microscopic findings, the defects were filled with woven bone at the 6th week and compact bone at the 12th week, and the osseointegrations were seen in both groups. There was no histological difference between them. 2. On the basis of the histomorphometric analysis, BMP group(6th week: 40.25%, 12th week: 56.04%) had higher bony contact ratio than DFDB group(38.37%, 42.63%). There was significant difference between two groups at the 12th week(p<0.05). 3. The amount of bone formation in BMP group was more prominent than in DFDB group. Significant difference was noted among two groups at the 6th and the 8th week(p<0.05). 4. By the transmission electron microscopic findings, $0.4-2{\mu}m$ soft tissue layer was found in adjacent to the interfaces and over the collagen fibrils of bone at the 6th week. However, about 100nm amorphous layer was noted at the interface or collagen fibrils directly extended to the titanium surface at the 12th week. There was no significant difference between two groups. 5. These results suggest that BMP and DFDB can be used as good graft materials in the regeneration of bone adjacent to implant, and BMP is more valuable as a bone inducer than DFDB.

  • PDF