• Title/Summary/Keyword: 매설 깊이

Search Result 150, Processing Time 0.024 seconds

Study for Rigid and Flexible Pipe Interaction at the Crossing Point of Underground Pipeline Network (지하 매설 교차 관망 내 강.연성관의 상호작용에 관한 연구)

  • Kim, Mi-Seung;Won, Jong-Hwa;Kim, Moon-Kyum;Kim, Jeong-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.30-35
    • /
    • 2009
  • The result of this research explains an interactive behavior of buried steel pipe located below hume pipe using concept of effective depth and effective length against their intersection angle and burial distance. The cover depth of upper rigid (hume) pipe is 1.0m and depth range of flexible (steel) pipe is 0.5m to 5m from beneath bottom of hume pipe. And one more variable is their intersection angle in this study, it was considered from $0^{\circ}$ to $90^{\circ}$. From the results of this study, the effective depth is proportionally increasing with its intersection angle and decreasing with distance increment between two pipes. Finally, the relationship between effective length and summation of occurred bending stress is defined.

  • PDF

Bearing Capacity of Shallow Foundation on Geosynthetic Reinforced Sand (토목섬유로 보강된 얕은기초 모래지반의 지지력)

  • Won Myoung-Soo;Ling Hoe I.;Kim You-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.7
    • /
    • pp.107-117
    • /
    • 2004
  • A series of model tests were conducted to investigate how the number of reinforcement layers, stiffnesses, types of reinforcement material and buried depth of a flexible pipe can affect bearing capacity-settlement curve at a loose sand foundation. In the test results, whereas the type of failure in unreinforced sand was local shear, the type of failure, for model tests with more than 2 reinforcement layers in loose sand, was general shear: The number of the optimum reinforcement layers was found to be two: Stiffness and type of reinforcement were more important than the maximum tensile strength of reinforcement in improving bearing capacity. When the depth of buried pipe from the sand surface was less than the width of the footing, test results showed that both bearing capacity and ultimate bearing capacity of buried pipe in unreinforced sand significantly decreased, and the type of failure in the reinforced sand changed from general shear to local shear.

Experimental and Field Investigations for the Accuracy of the Frost Depth Indicator with Methylene Blue Solution (실내실험과 현장실험을 통한 Methylene Blue 동결깊이 측정장치 신뢰성 검토에 관한 연구)

  • Kim, Hak Seung;Lee, Jangguen;Kim, Young Seok;Kang, Jae-Mo;Hong, Seung-Seo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.75-79
    • /
    • 2013
  • The frost depth is one of important factors in the design of structures such as roadways, buried pipeline, and foundations. A frost indicator with methylene blue solution has several advantages with respect to installation cost, maintenance, and simple measurement. However, as a geotechnical engineering aspect, the accuracy of the frost indicator has not been proved yet. This paper presents experimental and field investigations of the accuracy of the frost indicator and contour maps of maximum frost depth. The contour maps of maximum frost depth can be applied to design geo-infrastructure in South Korea.

Numerical Analysis of Electrical Resistance Variation according to Geometry of Underground Structure (지하매설물의 기하학적 특성에 따른 전기저항 변화에 대한 수치 해석 연구)

  • Kim, Tae Young;Ryu, Hee Hwan;Chong, Song-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.49-62
    • /
    • 2024
  • Reckless development of the underground by rapid urbanization causes inspection delay on replacement of existing structure and installation new facilities. However, frequent accidents occur due to deviation in construction design planned by inaccurate location information of underground structure. Meanwhile, the electrical resistivity survey, knowns as non-destructive method, is based on the difference in the electric potential of electrodes to measure the electrical resistance of ground. This method is significantly advanced with multi-electrode and deep learning for analyzing strata. However, there is no study to quantitatively assess change in electrical resistance according to geometric conditions of structures. This study evaluates changes in electrical resistance through geometric parameters of electrodes and structure. Firstly, electrical resistance numerical module is developed using generalized mesh occurring minimal errors between theoretical and numerical resistance values. Then, changes in resistances are quantitatively compared on geometric parameters including burial depth, diameter of structure, and distance electrode and structure under steady current condition. The results show that higher electrical resistance is measured for shallow depth, larger size, and proximity to the electrode. Additionally, electric potential and current density distributions are analyzed to discuss the measured electrical resistance around the terminal electrode and structure.

Development of Underground Facilities Management System on Subway Construction (지하철공사를 위한 지하매설물관리시스템 개발)

  • 강인준;장용구;정영미
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 1997
  • In other to construct a subway, we have to consider the position of the subway and acquisition of a topography, profile-map, cross-map, underground facilities map. All information of underground is demanded accurate location in other to prevent of accident of underground in subway construction. We must think about water lines, sewer lines, electronic lines, telephone lines, all urban gas-line because these are needed construction the subway. And attributes of underground facilities recorded on topography are characteristics. length, width. number, position, and depth of the lines. We have to record these attributes because these are very important to design map on subway construction. If we develop GIS (Geographic Information System) to use the exact in-formation of the underground facilities, we can be management safely and prevent very dangerous accident as fast as possible. In this study, attribute informations are linked geographic informations about underground facilities and we can develop Underground Facilities Management System(UFMS) to analysis dangerous region through dangerous degreed and predict accident range with these informations.

  • PDF

Contact Pressure around the Buried Rigid pipe under Embankment (성토하에 매설된 강성관의 접촉응륜력)

  • 안중선;강병희
    • Geotechnical Engineering
    • /
    • v.1 no.2
    • /
    • pp.7-16
    • /
    • 1985
  • The behaviour of buried rigid pipe under embankment is analysed by a linear finite element program to study the influence of variation of the geometry of soil-conduit pipe system and elastic modulus of soil on the pipe response. The geometry of the system considered includes the thickness of pipe, the height of embankment, and the width arid the depth of trench. The normal contact pressure distribution around the pipe and the vertical load on the pipe are modelled by a multiple linear regression. And the vertical load on the pipe computed by Marston-Spangles Theory Is generally larger than that by finite element analysis. The settiement ratio in Marston-Spangler Theory is found to be variable for various for various of all factors mentioned above.

  • PDF

A research on Mechanical property and safety degree of laying pipe Line ("매설관로의 역학적 특성 및 안전도에 관한 연구")

  • 김경진
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.1
    • /
    • pp.7-13
    • /
    • 1982
  • The program of safety performance of synthetic resin pipe which is used to the pipe Line for cable protection as an underground Communication is recognized importance gradually. For investigating of these, The Mechanical experiments by each type was carried out From the results, This study compared experimental data with theorical data against soil pressure and traffic pressure which went through laying pipe, and presumed the reasonable laying conditions after calculating total pressure by each laying depth, also grasped material Property of laying pipe and knew impact effect, relation of thickness against strain.

  • PDF

FEM Analysis of Controlled Low Strength Materials for Underground Facility with Bottom Ash (바톰애쉬를 이용한 지하매설관용 유동성뒤채움재의 FEM 해석)

  • Lee, Kwan-Ho;Lee, Kyung-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2368-2373
    • /
    • 2012
  • In this research, finite element method was carried out to evaluate the defomation of pipe and surface displacement for backfill of underground ficility. Various conditions for analysis were employer, including two different pipes(PE and concrete pipe), two different excavation depth(60cm and 150cm) and width(1.5D and 2D), a regular sand backfill, and four different flowable backfills. The vertical deformation of 60 cm diameter for PE was measured three times more than that of 30 cm diameter. The measured deformations for regular backfill and four flowable backfills were 0.320mm, and 0.135mm to 0.155mm, respectively. It ratio was around 40%. In case of 30cm diameter of concrete pipe, the measured vertical defomation was around 0.004mm for all the backfill materials. In case of installation depth, the effect of flowable backfill for flexible pipe is better than for rigid pipe. There is little effect on the deformation of concrete pipe with regular sand backfill and flowable backfill.

An Experimental Study on Detecting materials of GPR for Maintenance of Restored Cavities (복구된 공동의 유지관리를 위한 GPR 탐사용 탐지물질에 관한 실험적 연구)

  • Park, Jeong Jun;Shin, Eun Chul;Park, Kwang Seok;Shin, Hee Soo;Hong, Gigwon
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.430-439
    • /
    • 2018
  • Purpose: The purpose of this study is to verify the effectiveness of maintenance method using GPR exploration by buried detective materials in the ground for efficient maintenance of recovered cavities. Method: EMI sheet, EMI paint, and ferronickel slag were used as the detection materials, and the experiment was conducted by varying the size and depth of the buried detectable material. Results: As a result of the exploration, Detectable influence range by GPR exploration was found depending on the size and depth of buried detectable material in all materials, and the possibility of using it as a detection material was confirmed.

Estimation of burial depth for arctic offshore pipelines by an ice scour model (빙쇄굴 모델에 의한 극지 해저 파이프라인의 매설깊이 산정)

  • 윤기영;최경식
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.1-10
    • /
    • 1997
  • The interaction of ground ice features with underlying seabed is one of the major considerations in the design of Arctic pipeline systems. Regarding the development of offshore gas field near Sakhalin Island, which is an ice-infested area, in this paper an ice scour model to determine the burial depth of Arctic offshore pipeline is studied. Using a simplified ice-seabed interaction process, ice scour depth is easily estimated. This nonlinear numerical model can simulate the scouring process for various enviromental parameters such as ice mass, incoming velocity, soil strength. This study also deals with interaction forces during the scouring process in sloping seabed conditions and discusses the ice loads that are transmitted through the seabed soil.

  • PDF