• Title/Summary/Keyword: 매설간격

Search Result 41, Processing Time 0.032 seconds

Earthquake Fragility Analysis of a Buried Gas Pipeline (매설가스배관의 지진 취약도 해석)

  • Lee, Do-Hyung;Jeon, Jeong-Moon;Oh, Jang-Kyun;Lee, Du-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.5
    • /
    • pp.65-76
    • /
    • 2010
  • In this paper, earthquake fragility analysis has been comparatively performed with regard to a buried gas pipeline of API X65 which has been widely used in Korea. For this purpose, a nonlinear time-history analyses has been carried out for 15 different analytical models of a buried gas pipeline in terms of the selected 12 sets of earthquake ground motions with 0.1g of scaling interval. Following that, earthquake fragility analyses have been conducted using the maximum axial strain of the pipeline obtained from the nonlinear time-history analyses. Parameters under consideration for subsequent earthquake fragility analyses are soil conditions, end-restraint conditions, burial depth and the type of pipeline. Comparative analyses reveal that whereas the first three parameters influence the fragility curves, particularly soil conditions amongst the three parameters, the last parameter has a little effect on the curves. In all, the present study can be considered as a benchmark fragility analysis of a buried gas pipeline in the absence of an earthquake fragility analysis of the pipeline and thus is expected to be a useful source regarding earthquake fragility analyses of a buried gas pipelines.

ESTIMATING THE VOLUME OF CONSTRUCTION-WASTE LANDFILL USING GEOPHYSICAL TECHNIQUES (물리탐사 기법을 이용한 건축 폐기물 매립지의 규모 파악)

  • Mun,Yun-Seop;Lee,Tae-Jong;Lee,Chae-Yeong;Yun,Jun-Gi
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Dipole-dipole resistivity and ground penetrating radar(GPR) surveys were performed on an abandoned landfill site filled with asbestos containing material. The main purpose of the study was to estimate spatial extension and volume of the landfill for evaluting the cost for developing appropriate remedial alternatives. Assuming that the bedrock is within 10 m depth, dipole spacings of 2, 2.5 and 5m were set for six survey lines for resistivity measurements. For More detailed information, GPR suvey using 225 Mhz antenna was carried out for twelve survey lines for the shallower information. DC resistivity structures showed few tens ~ hundreds ohm-m for the landfill or alluvial laver, and 1,000~ 5,000 ohm-m for the bedrock. The depth to bedrock is found out to be approximately 5m. GPR survey results represented very clear reflection and/or diffraction events from the boundaries as well as from the blocky construction wastes. With high-resolution GPR survey, depth of the bedrock was resolved up to 2m, which in turn, could be a good indicator for estimating the volume of the landfill. Those depths of bedrock were confirmed by backhoe excavation data for 13 sites. The total area and volume of the landfill were to be approximately 3,953 .$m^2$ and 4,033 $m^3$, respectively.

  • PDF

A Study of Rectangular-shaped Passive Row Piles in Horizontal Sand-ground under Lateral Soil Movement by Model Test (수평모래지반에서 측방변형을 받는 사각형 수동 열말뚝에 관한 실험적 연구)

  • Bae, Jong-Soon;Kwon, Min-Jea
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.23-36
    • /
    • 2008
  • This study describes model tests on instrumented rectangular-shaped passive row piles embedded in horizontal sand-ground undergoing lateral soil movement. We tried to find the property of row piles dependent on the shape of pile, including the position of the pile in row, pile spacing, and soil movement. The results of test are as follows. The lateral earth pressure diagram variously appeared to be triangle, trapezoid and rectangular by shape and position of pile. The outer pile has a larger bending moment than the inner pile in the case of B-type, the inner piles has larger one than outer pile in case of H-type. $R_f$ (the ratio of resistance to lateral soil movement) was found to increase with increasing pile spacing irrespective of pile-shape. Y/L (location of action of lateral resistance force) for $d_s$ (displacement of soil) and $S_h$ (spacing of pile) appeared to be nearly regular position, and H-type is higher than B-type.

Magnetic Field Analysis according to Line Configuration in Underground Transmission Systems (지중송전계통에서 선로구성에 따른 자계해석)

  • Lee, Jae-Myeong;Son, Yong-Dae;Go, Kwang-Man;Chea, Jik-Byoung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.389-390
    • /
    • 2015
  • 최근 송전선로 주변의 자계에 대한 관심이 집중되고 있는 가운데 가공송전선로에 대한 검토는 많이 이루어졌으나 지중송전선로에 대한 검토는 가공에 비해 부족한 가운데 있다. 이에 따라 본 논문에서는 지중송전계통에 포설된 지중송전케이블에서 발생하는 자계를 구성조건 즉, 케이블 배열, 매설 깊이, 도체 간격 등 다양한 조건에서의 검토를 통하여 자계의 저감 방안을 제시하였다.

  • PDF

Seismic Refraction Survey for Installation of Water Pipe on a Side of the Seomjin River near Namwon (남원 섬진강변 관로 매설을 위한 굴절파 탐사)

  • Kim, Gi Yeong;U, Nam Cheol;Kim, Hyeong Su
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.209-216
    • /
    • 1999
  • In order to get geologic information necessary for underground installation of water pipe, seismic refraction profiling was applied to the southwest side of the Seomjin River which flows between Namwon-gun, Cholabuk-do and Gokseong-gun, Cholanam-do. Before obtaining the in-line refraction data, walkaway data were recorded with 1 m geophone interval and -36∼+36 m offset range. From the walkaway data, it is interpreted that a dry soil layer with the average velocity of 585 m/s covers wet sediments with the average velocity of 1,326 m/s. The second layer overlies basements nearly horizontally with the average velocity of 4,218 m/s. Refraction profiling of 220 m long with the geophone interval of 2 m is interpreted with the Generalized Reciprocal Method (GRM). Three layers are identified with average velocities of 688 m/s, 1,473 m/s, and 3,776 m/s, respectively. The depth to the bedrock impossible for ripping ranges between two extremes, 1.51∼2.43 m and 2.25∼3.54 m, depending upon thickness of the hidden layer. A typical shortcoming of refraction method, the hidden layer problem, prevents accurate estimation in depth of the second layer.

  • PDF

Application of Relative Gravity Surveying and Modeling to Sinkhole Detection (싱크홀 탐지를 위한 상대중력측량과 중력모델링 기법의 활용)

  • Kim, Jinsoo;Lee, Young-Cheol;Lee, Jung-Mo
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • The purpose of this research was to develop and present methods to detect sinkholes which can exist underneath the surface of the ground. First, we buried a water tank with dimensions $1.8{\times}0.8{\times}0.8m$ at a distance of 1.8 m from the surface. This played the role of the sinkhole. Secondly, we created a square zone with sides 12 meters away from the buried water tank. Within this zone, we measured the gravity at 1-meter intervals using a Scintrex CG5 relative gravimeter with a resolution of 0.001 mGal. Additionally, we performed three-dimensional (3-D) gravity modeling to calculate the theoretical values of the relative gravity around our model sinkhole. The resulting values for the relative gravity around the sinkhole depended on the method used. The measured effect of gravity was 0.036 mGal and the effect calculated using 3-D modeling was 0.024 mGal. Our results suggest that sinkholes that are similar in size to the water tank used in this study can be detected using relative gravity surveys. Smaller sinkholes can be detected by reducing the intervals between the relative gravity measurements.

A Study on Seismic Protection Equipment for Fire Pipes Installed on Buildings (건축물에 설치되는 소방용 배관의 내진장치에 관한 연구)

  • Lim, Geon-Tae;Lim, Sang-Ho
    • Industry Promotion Research
    • /
    • v.4 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • This study is a technology related to a seismic protection device for a fire pipe for installation in a building such as an apartment or a building. The fire pipe is fixed to the base panel by fastening bolts so as to flow left and right. The present invention relates to an earthquake-resistant apparatus for a fire-extinguishing piping, which is capable of minimizing damages caused by an earthquake in order to prevent damages and breakage of a fire-extinguishing pipe by mitigating earthquakes, vibrations, It is connected to an insert plate embedded in concrete or ceiling hanger bolts formed at regular intervals on the ceiling to keep the piping constant from the ceiling and to keep the horizontal condition of the piping always constant so that the piping relaxes or sags And to effectively prevent damage to the piping. The can get.

The Study of Group Piles under Lateral Soil Movement in Sand by Model test (모래지반에서 측방변형을 받는 무리말뚝의 실험적 연구)

  • Bae, Jong-Soon;Kim, Sung-Ho;Kwon, Min-Jea
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.165-172
    • /
    • 2006
  • This study describes a series of model tests on instrumented pile groups embedded in HAP-CHEN sand undergoing lateral movement. We tried to find the effect of group piles dependent on a number of factors, including the position of the pile in a group, the pile spacing, and the pile arrangement. The results of test are as follows. For the group piles, the bending moment profile for each pile is similar in shape to that of single pile, although the magnitude and the position of the maximum bending moment are different. $R_M$ (the ratio of maximum bending moment) and $R_F$ (the ratio of resistance to lateral soil movement) were found to increase with increasing pile spacing. When a pile is in a group under lateral soil movement, RM increased in the order of the middle row, front row, back row, according to the direction of lateral deformation, and the outer pile has a larger RM than the inner pile.

The Development of Real-Time Leak Monitoring System for Management of Hazardous Material Pipeline (유해물질 이송관로 파손누출 실시간 예방 및 감시 기술개발)

  • Chae, Sookwon;Seo, Jaesoon;Kim, Joonseok
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.2
    • /
    • pp.122-129
    • /
    • 2016
  • In this study, a dual structured pipe for a preventive monitoring on a accident damage, a smartphone app program for a survey and a construction data collection and a server program for a real-time monitoring were developed. A pilot system was installed in the test field to analyze effects of a system developed in this study. The data for a damage prevention was detected by the attached sensors on the pipe. Exclusion was tested by the pressure sensors to be installed at regular intervals. The app and server programs was enabled to the real-time data collection and real-time monitoring linked by VRS survey equipments and a smartphone.

Consolidation Analysis of Dredged Fill Ground Installed with Horizontal Drains (I) - Program Development and Verification - (수평배수재가 포설된 준설매립지반의 압밀해석(I) - 프로그램 개발 및 검증 -)

  • Park Chung-Yong;Jang Yeon-Soo;Park Chung-Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.27-39
    • /
    • 2005
  • A finite difference program with 3-D governing equation expanded from 1-D self-weight consolidation is developed to analyze the consolidation behavior of surface dredged soil with horizontal drains. Various boundary conditions with horizontal drains and seepage pressure of pore water infiltrated to the drains are considered in the program. A laboratory soil chamber experiment for the consolidation of dredged soil is performed to validate the program and the measured settlement-time result is compared with the one predicted by the program. The influence of design conditions of horizontal drains such as horizontal installation spacing, installation depth and number of drain layers, on the consolidation is analyzed.