• Title/Summary/Keyword: 망상골

Search Result 33, Processing Time 0.026 seconds

A Study of the Mechanical Properties of Human Trabecular Bone by Spherical Indentation Test (구형압입시험을 통한 망상골의 기계적 물성 연구)

  • 배태수;김정규;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.419-424
    • /
    • 2001
  • We intended to evaluate the Young's modulus of trabecular bone of a human distal femur by spherical Indentation test and CT images and to quantify relationships between the direction of load, density. and Young's modulus. The specimens were scanned at 1 mm intervals on CT scanner After scanning the bones were sectioned with diamond saw. producing 8mm cubes of trabecular bone. The tubes were mechanically tested in inferior-superior(IS), anterior-posterior(AP). and medial-lateral(ML) direction with custom-made device. After testing, the real apparent density of specimens were measured. The results of this study showed that the IS modulus was significant1y greater than both the AP and ML modulus and the AP modulus was also greater than ML modulus significantly(p〈0.01) A significant Power relationship between the apparent density and the modulus was also found.

  • PDF

The Study of Changes in Compressive Strength of Trabecular Bone with PMMA Injection in Vertebroplasty (척추성형술에서 PMMA 주입에 의한 망상골의 압축강도 변화 연구)

  • 문희옥;이문규;김정규;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.369-373
    • /
    • 2003
  • The compressed fracture of spine caused by osteoporosis is one of the most frequent diseases in bone fracture. Recently the vertebroplasty has drawn much attention as a medical treatment for the compressed fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. But because there were no research about strengthening of mechanical properties of verbral body in bone cement injection, in this study, based on the properties of PMMA, we had measured the Young's modulus for different apparent densities of intact trabecular bone and PMMA injected one from a porcine and a cadaver. Young's modulus to apparent density had a form of a power series in intact trabecular bone and had a linear relation in PMMA injected bone.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Treatment of Benign Bone Lesions with Autologous Bone Marrow Stromal Cell Transplantation (자가 골수 기질 세포 이식을 이용한 장관골 양성 골 병변의 치료)

  • Rhee, Seung-Koo;Kang, Yong-Koo;Kim, Yong-Sik;Bahk, Won-Jong;Chung, Yang-Guk;Kim, Hyoung-Jun;Ok, Ji-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • Purpose: We analyzed the result of autologous bone marrow stromal cell transplantation with or without cancellous chip bone allograft for benign long bone lesions. Materials and methods: Since July 1996, eight benign bone lesions treated by curettage, cancellous chip bone allograft and bone marrow or marrow stromal cell transplantation were observed for resolution of clinical symptoms, new bone formation and consolidation. There were 6 males and 2 females. Average age was 24 (range 8 to 47) years old. Histologic diagnoses were 5 fibrous dysplasia, 2 simple bone cysts and one chondroblastoma and fibrous cortical defect each. Mean follow-up period was 16.3 (range 3 to 84) months. Results: In all four symptomatic patients, the pain was subsided in two weeks after surgery. New bone formation in the lesion was observed at 4 weeks, which incorporated into surrounding normal bone around 8 weeks. There were one pathologic fracture through the lesion at 3 weeks and one recurrence of simple bone cyst at 5 months postoperatively. Conclusion: Bone marrow or marrow stromal cell transplantation for bone defects from curettage of benign bone lesions, with or without cancellous chip bone allograft revealed rapid healing. Though it was the result of short-term follow up, it supports that bone marrow stromal cell transplantation will be very useful for the treatment of benign long bone cysts or other lesions. The complete curettage of inner cystic wall is important to prevent later recurrence, and the rigid internal fixation is also needed in selected high risk lesions of fracture.

  • PDF

Effects of trabecular bone microstructure on stress distribution within premolar tooth and implant (망상골의 구조와 밀도가 치과용 임플란트와 하악골에 미치는 영향)

  • Chon Chang Soo;Lee Sang Up;Lee Kyoung Joung;Kim Han Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.210-217
    • /
    • 2005
  • This study examined the effect of cancellous bone microstructure on stress distribution within a premolar tooth and a dental implant against mastication force by the micro-finite element method (FEM). The mandibular specimen including a premolar was obtained from a cadaver and scanned with micro-CT to obtain CT images. FE models were reconstructed from CT images at mid-sagittal plane of the tooth. Six models were generated and analyzed for different structure and density in cancellous bone. Stress distributions fur each implant (or tooth) and the surrounding bone were compared. The study indicated that the microstructure of cancellous bone should be considered in finite element analysis to produce reasonable results and thus implant systems with high success rate.

MANDIBULAR RECONSTRUCTION WITH THE COMBINATION OF PMCB AND CORTICAL BONE IN TITANIUM MESH TRAY (자가 입자 골수 망상골과 치밀골을 이용한 하악골 재건술-증례보고 1례-)

  • Yi, Chung-Guk;Park, Hyeong-Rae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.3
    • /
    • pp.87-91
    • /
    • 1990
  • This is to report a case of secondary reconstruction after partial mandibulectomy by using of marrow-cancellous bone and cortical bone harvested from the iliac crest in the case of an ameloblastoma on the mandible. According to the past experimental studies, the marrow and cancellous bone have the marked osteogenic potential of hematopoietic. And the cortical bone has the highest activity of bone induction, which is mediated through the action of bone morphogenic protein(BMP). This grafting technique, the combination of PMCB and cortical bone, has advantage in restoring lange defect of the mandible.

  • PDF

CASES REPORT OF CLEFT ALVEOLUS REPAIR WITH PMCB GRAFT (치조골 파열환자의 자가망상골 이식을 이용한 치험례)

  • Lee, Dong-Keun;Choi, Seong-Hoon;Chung, Hyung-Bai
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 1991
  • The cleft alveolus occurs about 75% of cleft lip and palate patients. The purpose of bone grafting is improve the maxillary growth, rehabilitation of continuty of maxillary arch and providing bone for periodontal support for unerupted teeth. The bone grafting for alveolar cleft defect repair are classsified; primary bone grafting, early secondary bone grafting secondary bone grafting and late secondary bone grafting. In this article, we reported the cases of PMCB grafts for repair of the alveolar clefts showed potential benifit to the patient to induce a normal maxillary growth and providing bone foor periodontal support of unerupted teeth.

  • PDF