• 제목/요약/키워드: 막비등

검색결과 61건 처리시간 0.026초

고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

액막류의 MHF 점에 관한 실험적 연구 (Experimental Study on Minimum Heat Flux Point of Liquid Film Flow)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.208-213
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increase with increasing the velocity and the subcooling of the liquid film flow.

  • PDF

電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究 (A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle)

  • 정문기;박종석;이영환
    • 대한기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-14
    • /
    • 1986
  • 본 연구에서는 가압경수형 원자로심을 모의하는 3*3배열로 된 모의연료 봉다발의 실험장치를 이용하여 재완수과정의 유동특성과 열전달특성을 파악하였으며, 재완수과정중 연료봉의 온도거동을 예측하는 REFLUX코드를 최근 개발된 연구자료를 토대로 수정하여 본실험결과와 비교하였다.

액적의 리바운드 모션에 주목한 분무냉각 막 비등 열전달 모델 (Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.287-293
    • /
    • 2005
  • In the present study, to determine the flow rate of droplets supplied to heat transfer surface after (j-1)th rebound, $D_X[j{\ge}2]^{\ast}$, it was assumed that the rebound droplets are distributed according to the Gaussian distribution from 0 to L, in which the flight distance L is determined by maximum flight distance $L_{max}$. We also assumed that $L_{max}$ is dependent on the air flow velocity and mean size of droplets. The local heat flux of a dilute spray in high temperature region was predicted using the newly evaluated $D_X[j{\ge}2]^{\ast}$. In addition, the predicted results by the present model were compared with the existing experimental data.

高溫表面의 冷却時 再水着 溫度 에 관한 硏究 (A Study of Rewetting Temperature in Cooling of Hot Surfaces)

  • 정문기;이영환;박종석
    • 대한기계학회논문집
    • /
    • 제9권4호
    • /
    • pp.463-470
    • /
    • 1985
  • 본 논문에서는 가열관을 이용한 실험과 고온표면위에 놓인 물방울의 증발실험 을 통하여 재수착온도에 미치는 영향인자들을 분석하였으며, 이러한 분석결과를 토대 로 재수착온도상관식을 제시하였다.

액막류의 MHF점에 관한 실험적 연구

  • 김영찬;서태원
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.960-965
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increases with increasing the velocity and the subcooling of the liquid film flow.

  • PDF

고온 평판의 분무냉각에 있어서 MHF점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

열간압연 이후 주행하는 고온 강재의 냉각해석에서 소재의 물성변화 효과 연구 (Study for Effect of Changes in Thermal Properties on Cooling Process in Running Hot Steel Strip After Hot Rolling)

  • 박일석;박정은
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.459-465
    • /
    • 2013
  • 열연 판재 제조과정에서는 제품의 강도와 인성을 제어하기 위해 압연 직후 $800^{\circ}C$ 이상의 고온 소재를 수냉각 방식으로 급속 냉각시킨다. 이 과정에는 소재 표면과 냉각수 사이의 비등 열전달 현상과 소재 표면에 쌓이는 체류수의 자유표면 유동, 소재의 고속 주행 등 매우 복잡한 물리현상들을 포함하고 있다. 본 연구에서는 이 모든 물리 현상들을 수치적으로 모델링한 해석 모델을 적용하여 기본 열전달 해석을 수행한다. 실제로 소재는 냉각에 의해 내부에서 오스테나이트로부터 페라이트로 상변태가 일어나고 이로 인해 소재의 국부적인 열물성치의 변화가 발생하지만 본 연구에서는 상변태를 직접 푸는 방법 대신 이미 알려진 소재의 온도에 따른 물성변화 곡선을 이용하여 냉각해석을 수행하고 이를 기존의 일정 물성치 조건에서 해석한 결과와 비교하여 소재의 물성변화가 소재 냉각에 미치는 영향과 상변태 해석의 필요성에 대해 검토하였다.

유기막 위에 증착된 저온 ITO(Indium Tin Oxide) 박막의 식각특성

  • 김정식;김형종;박준용;배정운;이내응;염근영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.99-99
    • /
    • 1999
  • 투명전도막인 Ito(Indium Tin Oxide)는 flat panel display 와 solar cell 같은 optoelectronic 이나 microelectronic device에서 널리 이용되어 지고 있다. 현재 상용화되고 있는 거의 대부분의 ITO 박막은 sputtering법에 의해 제조되고 있으나 공정상의 이유로 15$0^{\circ}C$이상의 기판온도가 요구되어진다. 그런, 실제 display device 제조공정에서는 비정질 실리콘 박막이나 유기막 위에 ITO박막을 제작할 필요성이 증대되어 지고 있고, 또한 다른 전자소자에 있어서도 상온 ITO 박막 형성 공정에 대한 필요성이 증대되고 있다. 이러한 이유로 본 실험에서는 IBAE(Ion Beam Assisted Evsporation)을 이용하여 저온 ITO박막을 유기막 위에 증착하는 공정에 대한 연구를 수행하였다. 이렇게 증착된 ITO 박막의 결정성은 비정질이었다. 또한, 모든 display device 제작에는 식각공정이 필수인데 기존에 사용되고 있는 wet etching 법은 등방성 식각특성 때문에 미세 pattern 형성에 부적합?, 따라서 비등방성 식각에 용이한 plasma etching법을 사용하여 저온 증착된 ITO 박막의 식각특성을 알아보았다. 실험에 사용된 식각장비는 자장 강화된 유도결합형 플라즈마 식각장비(MEICP)를 사용하였으며, 13.56MHz의 RF power를 사용하였다. 식각조건으로 source power는 600W~1000W, 기판 bias boltage는 -100V~-250V를 가하였으며, Ar, CH4, O2, H2, BCl3의 식각 gases, 5mTorr~30mTorr의 working pressure 변화 그리고 기판 온도에 따른 식각특성을 관찰하였다. ITO 가 증착된 기판으로는 유기물 중 투명전도성 박막에 기판으로서 사용가능성이 클 것으로 기대되어지는 PET(polyethylene-terephtalate), PC(polycarbonate), 아크릴을 사용하여 기판 변화가 식각특성에 미치는 영향에 대해서 각각 관찰하였다. 식각속도의 측정은 stylus profiler를 이용하여 측정하였으며 식각후에 표면상태는 scanning electron spectroscopy(SEM)을 이용하여 관찰하였다.

  • PDF

알루미늄 평판 및 50 ㎛ 간격 격자 표면에 대한 에탄올 액적 충돌 거동 가시화 (Ethanol Droplet Impact Behavior Visualization on the Flat and 50㎛ grating groove Al Surface)

  • 강동국;권대희;천두만;염은섭
    • 한국가시화정보학회지
    • /
    • 제18권1호
    • /
    • pp.18-25
    • /
    • 2020
  • The droplet impact behavior is dominated by some parameters such as surface temperature, We number, surface and fluid property. Especially, Leidenfrost effect which prevents the contact between surface and droplet is very powerful phenomenon for determining droplet impact behavior. Due to this effect, the impact regime is divided into contact boiling regime and film boiling regime whether the droplet contact with the surface. Many studies have found that surface micro-structures which processed by surface processing are effective to overcome the Leidenfrost effect. In this study, droplet impact behaviors were compared using ethanol both on flat and laser-ablated Al surface. On the flat surface, impact regime was mainly divided by surface temperature. And there is key dominant parameter for each regime. On the laser-ablated surface, we could see changed impact regime and different impact behavior such as jetting and ejection of tiny droplets despite of same impact conditions.