• Title/Summary/Keyword: 막모듈

Search Result 307, Processing Time 0.023 seconds

Recovery of Useful Components from Rice-washing Water Using Membranes (분리막을 이용한 쌀뜨물내 유효성분의 회수)

  • 정건용;박성희
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.165-170
    • /
    • 2002
  • Membrane process was investigated to recover useful components, such as protein from rice-washing water generated in the production of the washed-rice. The filtration experiments were carried out using not only a dead-end Amicon cell to determine suitable membranes but also a hollow fiber ultrafiltration, spiral wound nanofiltration and reverse osmosis modules for home water purification. Ultrafiltration module(molecular weight cut-off : 10,000 dalton) was not suitable for recovery of useful components or protein in the rice-washing water, but nanofiltration and reverse osmosis modules showed a good performance. in the case of 250% concentration of the rice-washing water contained about 9% protein the proteins in concentrates of nanofiltration and reverse osmosis were 18% and 22%, which were about 2 and 2.4 times higher protein concentrations than those of feed, respectively.

Simulation on Recovery of Methane Greenhouse Gas from Biogas Using 3 Stage Membrane Modules (바이오가스로부터 온실가스 메탄 회수를 위한 3단 분리막 공정 모사)

  • Lee, Yongtaek
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.243-251
    • /
    • 2018
  • Methane is one of the important greenhouse gases and methane is the major component of the biogas. A multiple stage membrane process was developed and analysed with the numerical analysis so that the mole fraction of methane in the final product could be kept higher than 0.95 and simultaneously the recovery of methane was also maintained higher than 99% from the biogas using 3 polysulfone hollow fiber membrane modules which were properly connected. As the feed pressure of the biogas, the mole fraction of methane in the biogas and the membrane area in the membrane module are increased, the methane mole fraction of the final product are found to be increased. However, a proper membrane area in the module should be carefully selected in order to achieve the satisfactory goal of 0.95 mole fraction of methane and 99% recovery of methane from the biogas. Even if the multiple membrane process is utilized with the properly selected membrane modules, the limited operating ranges have to be applied in the following parameters : the feed pressure, the flow rate, the mole fraction of methane in the biogas to get both the target methane concentration and the recovery rate of methane.

Analysis of Membrane Fouling Reduction by Natural Convection Instability Flow in Membrane Filtration of Colloidal Solution: Application of Blocking Filtration Model (콜로이드 용액의 막여과에서 자연대류 불안정 흐름의 막오염 저감 효과 해석: 막힘여과 모델의 적용)

  • Kim, Ye-Ji;Youm, Kyung-Ho
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.329-338
    • /
    • 2019
  • The constant-pressure and constant-flux membrane filtration experiments of alumina colloidal solution are performed to investigate defouling effect of the natural convection instability flow (NCIF) induced in membrane module. The permeate flux at constant-pressure and the transmembrane pressure (TMP) at constant-flux experiments are measured by changes the inclined angle (0, 90 and 180°) of membrane module to the gravity, and flux results are analyzed by using the blocking filtration model. NCIF are more induced as the inclined angles increased from 0° to 180°, and the maximum induced NCIF at 180° angle enhances flux to 2.8 times and reduces TMP to 85% after two-hour operation. As a result of analyzing flux data by applying the blocking filtration model, it is more reasonable to analyze them by using the intermediate blocking model within 15-minute operation time and then thereafter times by using the cake filtration model. The induced NCIF at 180° angle reduces the intermediate blocking fouling at 52% in the early operation time of 15-minute and thereafter the cake layer fouling at 93%. The main membrane fouling control mechanism of NCIF induced in membrane module is evaluated as suppressing the formation of the cake layer of particulate colloidal materials on membrane surface.

The Effect of the Making Methods of Hollow Fiber Active Layer on Performance for Nanofiltration Helical Module (Nanofiltration Helical Module에서 Hollow Fiber Active Layer의 성형법에 따른 성능변화에 관한 연구)

  • ;Belfort, Georges
    • Membrane Journal
    • /
    • v.7 no.2
    • /
    • pp.95-109
    • /
    • 1997
  • The effects of varing axial flow rate and solute concentration on the performance of both module sets made by different methods for active layer formation were compared and determined. All experiments were conducted simultaneously at the same transmembrane pressure and energy consumption per membrane area. In every comparative run between the presence of Dean vortices in a helical module and absence of such vortices in a linear module from the first module set, the solution fluxes and permeabilities were higher, and in some cases substantially higher for the vortex flow. With pure water, the permeabilities of both modules from the second module set were different and the flux in a linear module was 150% higher than in the helical module. This explained both module membranes were totally different.

  • PDF

Evaluation of Tubular Type Non-woven Fabric Filter for Solid-liquid Separation in Activated Sludge Reactor (활성슬러지조내 부직포 여재 관형필터의 고액분리 특성 평가)

  • Seo, Gyu-Tae;Lee, Teak-Soon;Park, Young-Mi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.234-238
    • /
    • 2008
  • Coarse pore filter could be an alternative of membrane for solid-liquid separation in an activated sludge reactor because of inexpensive cost of the filter material and high flux at low filtration pressure. However such filter module has much less specific filtration area compared to the membrane. Therefore a certain effort is required to increase the specific filtration area in the module design of such coarse pore filter for solid-liquid separation in an activated sludge reactor. In this study, tubular type coarse pore filter was designed at various diameter and configuration. The filtration performance was investigated to separate solid in the activated sludge reactor for domestic wastewater treatment. Tubular type coarse pore filter module could be successfully applicable to solid separation in the activated sludge reactor. The design parameters were the tube diameter of 10mm and vertical installation. Smaller diameter of the tube caused faster increase of the filtration pressure because of the hydraulic head loss in the tube channel.

Ions Removal of Contaminated Water with Radioactive Ions by Reverse Osmosis Membrane Process (방사성이온으로 오염된 물의 역삼투막공정을 이용한 이온제거)

  • Shin, Do Hyoung;Cheong, Seong Ihl;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.26 no.5
    • /
    • pp.401-406
    • /
    • 2016
  • In this study, we have investigated the removal of the low level radioactive ions of Cs and I in water by the reverse osmosis (RO) process. The two RO modules produced in domestic region and the waste RO module after the cleaning process were selected. Then we compared removal performance of both Cs and I. The experiments are conducted by varying the concentration of feed, the pressure. As a results, it was confirmed that all three modules are higher I decontamination factor than Cs. And particularly, for the cleaned RO module, its decontamination factor of I was 1140. Since the results at low pressure condition were better than that at high pressure conditions, the use of the direct installation of RO modules on the tap water might be possible. In addition, it was confirmed that the waste RO module after cleaning process using EDTA, SBS and NaOH, increased the decontamination performance better than before cleaning, in particular, the recovery ratio after cleaning was 6.3% higher.