• Title/Summary/Keyword: 마하젠더형 간섭계

Search Result 5, Processing Time 0.071 seconds

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Design and Analysis of Mach-Zehnder-Interferometer-Based Silica Planar Lightwave Circuit Triplexer (마하젠더 간섭계로 구성된 실리카 평판 광 도파회로 트라이플렉서의 설계 및 분석)

  • Lee, Tae-Hyung;Lee, Dong-Hyun;Chung, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.447-451
    • /
    • 2007
  • A triplexer based on a silica planar lightwave circuit Mach-Zehnder nterferometer(MZI) is proposed and its characteristics are analyzed through simulations. To separate 1310 nm band and $1480{\sim}1560nm$ band properly, the path length difference of an MZI is set to be the multiple and half of the wavelength 1310 nm and the balance of the directional coupler is optimized in the $1480{\sim}1560nm$ band. The same MZI is additionally cascaded to provide good crosstalk characteristics. The 1490 nm band and 1550 nm band are further separated using additional two stage MZI's. A three-dimensional BPM and transfer matrix method analysis predicts the low crosstalk characteristics and the fabrication-error-tolerance of the proposed triplexer.

A Study on Dip-Pen Nanolithograpby Process to Fabricate 2D Pbotonic Crystal for Planar-Type Optical Bio-Sensor (평판형 광-바이오센서 (Planar-Type Optical Bio-Sensor)용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim, Jun-Hyong;Lee, Jong-Il;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.381-383
    • /
    • 2005
  • 바이오센서 응용을 위한 대칭 및 비대칭 마하젠더 간섭계 광도파로 소자의 설계, 제작 및 광학적 응답특성을 평가하였다. 설계 제작된 광도파로 소자의 압력광원은 각각 1550nm와 632.8nm이고, 코어와 클래딩의 굴절률차는 0.45 $\Delta$%로 설계 제작하였다. 센서부(상위 클래드)의 금 박막의 미소 굴절률 변화에 따른 TE, TM모드의 특성을 분석하였다. 센서의 보다 높은 감도 개선을 위한 나노-광자결정 구조가 주목받고 있는데, 광자결정 구조의 구현를 위한 리소그래피 공정은 높은 분해능과 신뢰성 있는 나노스케일의 공정이 요구된다. 광-바이오센서의 감도 개선을 위해 센서부 표면에 2차원 나노-광자결정 배열을 제안하고 이를 구현하기 위한 Dip-Pen Nanolithography 공정에 대해 고찰하였다.

  • PDF

The Performance Analysis of Optical CDMA based Acoustic Sensor System using Optical Fiber Sensors (광 CDMA 기반광섬유 센서를 이용한 음파탐지 시스템의 특성 분석)

  • Park, Sang-Jo;Kim, Bong-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.956-962
    • /
    • 2008
  • We propose the optical CDMA based audio acoustic sensor using optical fiber sensors which can be used in the bottom of the sea. In the proposed network, we analyzed the performance of noise power. Numerical simulations confirm that the performance can be improved by increasing the measuring time of optical sensors compared with using conventional WDMA method.