• Title/Summary/Keyword: 마커입자

Search Result 7, Processing Time 0.023 seconds

Visualization of the Water Column Collapse by using SMAC Method (SMAC법을 이용한 물기등 붕괴의 가시화)

  • Kim, Nam-Hyeong;Kim, Nam-Guk
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.605-615
    • /
    • 2001
  • SMAC method, one of the numerical simulation techniques, is modified from the original MAC method for the time-dependent variation of fluid flows. The Navier-Stokes equations for incompressible time-dependent viscous flow is applied, and marker particles which present the visualization of fluid flaws are used. In this study, two-dimensional numerical simulations of the water column collapse are carried out by SMAC method, and the simulation results are compared with Martin and Moyce's experimental data and result of the MPS method. A good results are obtained. This numerical simulation could also be applied to the breaking phenomenon of hydraulic structures such as dam break.

  • PDF

The visual Simulation of Fluid Flow with Free Surface in a Virtual Water Tank (가상수조에서 자유표면을 가진 유체흐름의 가시화시뮤레이션)

  • 김남형;김남국
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.3
    • /
    • pp.35-40
    • /
    • 2000
  • SMAC method is, one of the numerical simulation techniques, modified from the original MAC for the time-dependent variation of fluid flows. The Navier-Stokes equation for incompressible time-dependent viscous flow is applied and, also marker particles which move with the fluid are used. Two-dimensional numerical computations of fluid flow are carried out in a virtual water tank. This paper has shown very well the movements of marker particles using SMAC method.

  • PDF

Nanoparticles in Healthcare: Development and Applications (생체 기능 모니터링용 나노 소재 개발 및 응용)

  • Lee, Hyojin
    • Prospectives of Industrial Chemistry
    • /
    • v.22 no.6
    • /
    • pp.13-25
    • /
    • 2019
  • 건강한 미래, 건강 사회 구현과 함께 질병 진단, 치료, 예방에 대한 관심이 급증하고 있다. 이에 따라 적시적기에 질병을 치료하고 예방하기 위한 건강 검진용 바이오센서 수요가 증가하였고 이에 따라 바이오센서 시장은 전세계적으로 급격히 확장되고 있다. 혈액 샘플을 기반으로 한 검진 방법이 보편적이지만 최근에는 고감도 센서 개발에 따라 소변, 침, 눈물 등과 같은 체액으로도 검진이 가능한 환자 친화적 비침습 센싱 방법도 활발하게 연구되고 있다. 이러한 센서 시장 패러다임의 변화 및 급속한 발전은 마이크로, 나노 재료 제작과 분석 기술 발전으로 체액 내 존재하는 나노 크기의 바이오 마커(단백질, 유전자, 펩타이드, 사이토카인)를 검출하는 소형화된 고감도의 센서를 개발할 수 있게 되었고 그 결과 화학, 물리, 재료, 의약 등 다양한 학문 분야에서 다양한 형태의 센서가 활발히 보고되었다. 본 기고문에서는 바이오센서용 소재 중에서 나노입자에 집중하여 첨단 센서 구현을 위해 사용된 입자의 종류, 센서 내에서의 입자의 역할을 소개하고 나노입자의 광학적, 물리적 특성에 따른 타겟 물질 검출 방법 및 동향에 대해 논의하고자 한다.

Visual Modelling of the Overtopping using SMAC Method (SMAC법을 이용한 월파현상의 가시화 모의)

  • 김남형;김남국
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.46-52
    • /
    • 2001
  • SMAC method, one of the numerical simulation techniques, is modified from the original MAC method for the time-dependent variation of fluid flows. The Navier-Stokes equations for incompressible time-dependent viscous flow are applied, and Also marker particles which present the visualization of fluid flows are used. In this study, two-dimensional numerical simulations of the overtopping are carried out by SMAC method, and the simulation results are visualized, In addition to, motion pictures are made for efficient visualization of the simulation results. This numerical simulation could also be applied to the design of coastal structures as dike and revetment.

  • PDF

Development of Lateral Flow Immunofluorescence Assay Applicable to Lung Cancer (폐암 진단에 적용 가능한 측면 유동 면역 형광 분석법 개발)

  • Supianto, Mulya;Lim, Jungmin;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.2
    • /
    • pp.173-178
    • /
    • 2022
  • A lateral flow immunoassay (LFIA) method using carbon nanodot@silica as a signaling material was developed for analyzing the concentration of retinol-binding protein 4 (RBP4), one of the lung cancer biomarkers. Instead of antibodies mainly used as bioreceptors in nitrocellulose membranes in LFIA for protein detection, aptamers that are more economical, easy to store for a long time, and have strong affinities toward specific target proteins were used. A 5' terminal of biotin-modified aptamer specific to RBP4 was first reacted with neutravidin followed by spraying the mixture on the membrane in order to immobilize the aptamer in a porous membrane by the strong binding affinity between biotin and neutravidin. Carbon nanodot@silica nanoparticles with blue fluorescent signal covalently conjugated to the RBP4 antibody, and RBP4 were injected in a lateral flow manner on to the surface bound aptamer to form a sandwich complex. Surfactant concentrations, ionic strength, and additional blocking reagents were added to the running buffer solution to optimize the fluorescent signal off from the sandwich complex which was correlated to the concentration of RBP4. A 10 mM Tris (pH 7.4) running buffer containing 150 mM NaCl and 0.05% Tween-20 with 0.6 M ethanolamine as a blocking agent showed the optimum assay condition for carbon nanodot@silica-based LFIA. The results indicate that an aptamer, more economical and easier to store for a long time can be used as an alternative immobilizing probe for antibody in a LFIA device which can be used as a point-of-care diagnosis kit for lung cancer diseases.

Analysis of Human Serum Amyloid A-1 Concentrations Using a Lateral Flow Immunoassay with CdSe/ZnS Quantum Dots (Human Serum Amyloid A-1 단백질 농도 분석을 위한 CdSe/ZnS 양자점 기반의 Lateral Flow Immunoassay 방법 개발)

  • Fajri, Aidil;Goh, Eunseo;Lee, Sanghyuk;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.429-434
    • /
    • 2019
  • A lateral flow immunoassay platform utilizing antibody functionalized water soluble CdSe/ZnS semiconductor quantum dots (QDs) was developed for the analysis of human serum amyloid A-1 (hSAA1) in a buffer solution. hSAA1 was chosen as a target protein because it is regarded as a potential biomarker associated with early diagnosis and prognosis in patients of lung cancer. The immunoassay strip on a nitrocellulose membrane was fabricated by spraying two lines composed of a test line with a monoclonal antibody against hSAA1 (10G1) (anti hSAA1) and a control line of anti-chicken IgY. While the CdSe/ZnS QDs synthesized in an organic phase were transferred to a water phase by ligand exchange using carboxylic acid modified alkane thiol. The QDs was then conjugated to monoclonal antibody against hSAA1 (14F8) [anti hSAA1 (14F8)] and used as a fluorescent detection probe. The sequential lateral flow of hSAA1 in different concentration and QDs-anti hSAA1 (14F8) complex allowed to form the surface sandwich complex of anti hSAA1 (10G1)/hSAA1/QD-anti hSAA1 (14F8), which was then analyzed using fluorescence microscope. A 100 nM concentration of hSAA1 protein can be detected by naked eyes under an optimized lateral flow buffer condition with a sensing time of 5 mins.

Development of Voltammetric Nanobio-incorporated Analytical Method for Protein Biomarker Specific to Early Diagnosis of Lung Cancer (폐암 조기 진단을 위한 단백질 바이오마커 측정용 전압-전류법 기반의 나노바이오 분석법 개발)

  • Li, Jingjing;Si, Yunpei;Nde, Dieudonne Tanue;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.461-466
    • /
    • 2021
  • In this article, a portable and cost-effective voltammetric biosensor with nanoparticles was developed for the measurements of heterogeneous nuclear ribonucleoprotein A1 protein (hnRNP A1) biomarker which can potentially be used for lung cancer diagnosis. Gold nanoparticles were first electrodeposited onto screen printed carbon electrode (SPCE) followed by immobilizing a single stranded DNA aptamer specific to hnRNP A1 onto the electrode surface. Ethanolamine was also used when immobilizing DNA aptamer on the surface to prevent signals from non-specific adsorption events. Sequential injection of hnRNP A1 biomarker and anti-hnRNP A1 conjugated with alkaline phosphatase (ALP) onto the aptamer chip surface allows to form the sandwich complex of DNA aptamer/hnRNP A1/ALP-anti-hnRNP A1 on the electrode surface which further reacted with 4-aminophenyl phosphate (APP). The electrocatalytic reaction of the enzyme, ALP, and the substrate, APP, resulting in the oxidative current response changes at -0.05 and -0.17 V (vs. Ag/AgCl) against the hnRNP A1 concentration was measured using cyclic and differential pulse voltammetry, respectively. The Au nanoparticles-integrated voltammetric biosensor was applied to analyze human normal serum solutions possibly suggesting potential applicability for lung cancer diagnosis.