Pressure Drop due to Friction in Small Rectangular Channel (미소 사각 채널에서의 마찰 압력 강하)

  • Lim, Tae-Woo;Choi, Jae-Hyuk;Kim, Jun-Hyo;Choi, Yong-Suk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제18권5호
    • /
    • pp.461-467
    • /
    • 2012
  • An experimental study was carried out to measure frictional pressure drop in flow boiling to deionized water in a microchannel having a hydraulic diameter of $500{\mu}m$. Tests were performed in the ranges of heat fluxes from 100 to $400kW/m^2$, vapor qualities from 0 to 0.2 and mass fluxes of 200, 400 and $600kg/m^2s$. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. From the experimental results, it is found that the two phase multiplier decreases with an increase in mass flux. Measured data of pressure drop are compared to a few available correlations proposed for macroscale and mini/microscale. The homogeneous model well predicted frictional pressure drop within MAE of 29.4 % for the test conditions considered in this work.

Asymptotic Approach to Pressure Drop and Heat Transfer in a Rectangular Pipe with Shear-thickening Fluids (사각형 단면 파이프 내에서의 Shear-thickening 유체를 이용한 압력강하 및 열전달 예측에 대한 점근적 해석)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • 제13권4호
    • /
    • pp.23-30
    • /
    • 2011
  • 본 연구는 산업용 열교환기 및 상용 파이프의 최적 설계를 위하여 열교환기 내의 사각형 단면 파이프의 shear-thickening 비뉴톤 유체의 압력강하 및 대류 열전달률을 수치해석적으로 수행하였다. shear-thickening 유체의 구성 방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 확장 멱법칙 모델을 채택하였다. 파이프 내의 압력강하를 의미하는 마찰계수와 확장 레이놀즈 수의 곱은 기존 연구의 비교자료와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.018% 및 0.06% 내에서 일치함을 보였고, 대류 열전달률을 의미하는 뉴셀트 수는 문헌치와 비교할 때 뉴톤 유체 영역과 멱법칙 영역에서 각각 0.025% 및 0.14% 내에서 일치함을 보였다. 비뉴톤 확장 멱법칙 유체 모델의 형태를 띠는 shear-thickening 유체를 열교환기 또는 상용파이프 내의 사각형 단면 파이프 내에서 사용하면 유동지수(n)에 따라서 뉴톤 유체보다 최대 160%의 압력강하를 증가시켰고 최대 14%의 대류 열전달 감소를 발생시킬 수 있었다.

Prediction methods for two-phase flow frictional pressure drop of FC-72 in parallel micro-channels (병렬 마이크로 채널에서 FC-72의 2상 유동 마찰 압력 강하 예측)

  • Choi, Yong-Seok;Lim, Tae-Woo;You, Sam-Sang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.821-827
    • /
    • 2014
  • In this study, an experimental study was performed to predict the two-phase frictional pressure drop of FC-72 in parallel micro-channels. The parallel micro-channels consist of 15 channels with depth 0.2 mm, width 0.45 mm and length 60 mm. And tests were performed in the ranges of mass fluxes from 152.2 to $584.2kg/m^2s$ and heat fluxes from 7.5 to $28.3kW/m^2$. The experimental data was compared and analyzed with existing correlations to predict the pressure drop. The existing methods to predict the pressure drop used the homogeneous model and the separated model. In this study, the new correlation was proposed by modified existing correlation using the separated model, and the new correlation predicted consequently with the experimental data within MAE of 9.6%.

Pressure Drop Reduction and Heat Transfer Increase with Rheological Fluid Flows in a Circular Conduit (원형 도관 내에서의 유변 유체에 대한 압력손실 감소 및 열전달 증가)

  • Lee, D.R.
    • Journal of Power System Engineering
    • /
    • 제16권1호
    • /
    • pp.51-57
    • /
    • 2012
  • 본 연구는 컴팩트한 열교환기의 설계를 위하여 열교환기 내의 원형 단면 도관의 유변 유체의 압력 강하 및 대류 열전달률을 수치해석적으로 수행하였다. 유변 유체의 구성방정식은 기존의 비뉴톤 유체 멱법칙을 보완한 수정 멱법칙 모델을 채택하였다. 도관 내의 압력강하를 의미하는 마찰계수와 수정 레이놀즈 수의 곱은 기존 문헌치와 비교할 때 뉴톤 유체 영역과 유변 멱법칙 영역에서 각각 0.01% 및 0.004% 내에서 일치함을 보였고 유변 수정멱법칙 유체 모델의 형태를 띠는 유변 유체를 열교환기 내의 원형 단면 도관 내에서 사용하면 뉴톤 유체보다 최대 58%의 압력강하를 감소시켰고 최대 9%의 대류 열전달 증가을 발생시킬 수 있었다.

A Theoretical Approach on the Pressure Drop in Two-phase Particle-laden Flows (고체입자가 부상된 이상유동에서 압력강하에 대한 해석적 접근)

  • Kim Seyun;Lee Kye-Bock
    • Journal of Energy Engineering
    • /
    • 제14권1호
    • /
    • pp.11-17
    • /
    • 2005
  • The purpose of this research is to develop the model of pressure drop per unit pipe length due to the turbulence modulations in particle-laden flows which can be applied to various fluid conditions. The wake behind a particle, particle size, loading ratio and density difference between two phases of particle-laden flow was considered. The frictional pressure drop was modeled with the force balance in control volume. The numerical results show good agreements with available experimental data and the model success-fully predicted the mechanism of the pressure drop in particle-laden flows.

The study on the measurement for the pressure drop and friction factor of corrugated metal pipes (주름관에서의 압력강하와 마찰손실 계측에 관한 연구)

  • Yun, Young-Sun;Kang, Jun-One;Yoo, Jai-Suk;Kim, Hyung-Jung
    • Journal of the Korean Society of Visualization
    • /
    • 제4권2호
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF

An Investigation of Pressure Drop Characteristics of Finned Rod Bundles (핀 봉다발의 압력강하 특성 연구)

  • Chung, Moo-Ki;Chung, Chang-Hwan;Chung, Heung-June;Song, Chul-Hwa;Yang, Sun-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제23권3호
    • /
    • pp.328-339
    • /
    • 1991
  • A multi-purpose research reactor called KMRR has been developed by Korea Atomic Energy Research Institute(KAERI) to generate a maximum thermal output of 30 MW. As a part of thermal hydraulics study, pressure drop characteristics of the longitudinally finned fuel rod bundles were experimentally investigated in a recirculating water test loop. The present study is focused on the investigation of fin effects on pressure drop and the development of pressure drop correlation for the finned rod bundles in a wide range of flow conditions. Friction factor correlations for each design of the finned rod bundles are developed. The value of friction factor for the finned rod bundles was higher than the analytical solution (64/Re) of laminar circular channel new but became lower than the Blasius equation as Reynolds number was increased.

  • PDF

Effect of the lubrication oil on heat transfer and pressure drop characteristics of supercritical carbon dioxide in a microfin tube (마이크로핀관내 냉동기유가 초임계 이산화탄소의 열전달과 압력강하에 미치는 영향)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제13권4호
    • /
    • pp.1440-1446
    • /
    • 2012
  • This paper presents an experimental study of heat transfer and pressure drop characteristics of supercritical carbon dioxide with PAG inside a horizontal microfin tube. Heat transfer coefficient and pressure drop gradients were measured at 10 MPa in pressure and 520 kg/$m^2s$ in mass flux with variation of PAG mass concentration from 0.06% to 2.26%. The tendencies of both heat transfer and frictional pressure drop characteristics show the same as those of pure $CO_2$ up to 0.3% in PAG mass concentration. In case of 2.26% in PAG mass concentration, measured heat transfer coefficients showed 50% lower than those of pure $CO_2$ near the pseudocritical temperature and measured frictional pressure drop gradients show 1.6 times higher in comparison with those of pure $CO_2$ at $60^{\circ}C$ in $CO_2$ bulk temperature.

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • 제16권3호
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

Development of Pressure Drop Model for the Compartment in Reactor Containment (격납용기내 구분방사이의 압력 강하 계산모델 개발)

  • Park, Cheol;Song, In-ho;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • 제18권3호
    • /
    • pp.183-193
    • /
    • 1986
  • Full scale HDR containment experiment series pointed out that the previous containment analysis models have a number of shortcomings. One of them is on the calculational model of short term (0~2sec) pressure difference. The pressure differences between subcompartments are dependent on the flow rate, fluid density, head loss coefficient, and flow area ratio. It, however, is not known that any of them is largely attributed to the disagreement of pressure difference between the measured and the calculated values. In this study, the head loss coefficients are expressed with another form to improve the analytic model. The pressure and the pressure difference are evaluated by using COMPARE code with new correlation, and the results show better agreements with experimental values for V.42 test, but overestimate the measured values for V, 43 and underestimate for V.44.

  • PDF