• Title/Summary/Keyword: 링시편

Search Result 218, Processing Time 0.028 seconds

Relationship between Corrosion in Reinforcement and Influencing Factors Using Half Cell Potential Under Saturated Condition (습윤 상태에서의 반전위를 이용한 철근 부식과 영향 인자 간의 상관성 분석)

  • Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • In this study, the correlation between the influencing factors on corrosion and Half Cell Potential(HCP) measurement was analyzed considering the three levels of W/C ratio, cover depth, and chloride concentration. The HCP increased with enlarged cover depth, so it was confirmed that the increment of cover depth was effective for control of corrosion. Based on the criteria, the case of 60mm cover depth showed excellent corrosion control with under -200mV, indicating increase of cover depth is an effective method for reducing intrusion of external deterioration factors. When fresh water was injected to the upper part of specimens, very low level of HCP was monitored, but in the case that concentrations of chloride were 3.5% and 7.0%, HCP dropped under -200mV. In addition, the case with high volume of unit binder showed lower HCP measurement like increasing cover depth. Multiple regression analysis was performed to evaluate the correlation between the corrosive influence factors and HCP results, showing high coefficient of determination of 0.97. However, there were limitations such as limited number of samples and measuring period. Through the additional corrosion monitoring and chloride content evaluation after dismantling the specimen, more reasonable prediction can be achieved for correlation analysis with relevant data.

RFID Antenna Based on Ga-doped ZnO Transparent Conducting Oxide (Ga-doped ZnO 투명전도막의 RFID 안테나 응용)

  • Han, Jae-Sung;Lee, Seok-Jin;Jung, Tae-Hwan;Kim, Jeong-Yeon;Park, Jae-Hwan;Lim, Dong-Gun;Lim, Seong-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.78-79
    • /
    • 2009
  • 본 연구에서는 ZnO계 투명전극 소재를 이용하여 RFID 태그 안테나에 적용 가능성 여부를 확인하였다. Si 기판위에 RF 스퍼터링 공정에 의해 Ga-doped ZnO 투명 마이크로스트립 스파이혈 안테나를 $2{\mu}m$를 증착하여 구현하고 그 전기적 특성을 측정하였다. HFSS 전자계 시뮬레이터를 사용하여 13.56MHz HF 주파수 대역에서 태그 안테나로서의 가능성을 검증한 후 Ga-doped ZnO 타겟을 사용한 RF 스퍼터링 공정에 의하여 스파이럴 안테나 패턴을 구현하였다. 마이크로스트립 선폭 및 선 간격을 $50\sim200{\mu}m$때 영역에서 조절하면서 안테나 패턴을 설계하였다. S 파라메터, 자기공진주파수 및 Q값을 시뮬레이션으로부터 도출하였다. Al $2{\mu}m$ 증착한 시편에 비하여 약 -10dB 정도의 이득저하가 발생하였으나 리더-태그를 밀착시킨 조건에서 1.7V (13.56MHz) 전압검출이 가능하였다.

  • PDF

Determination of Constant Friction Factor and Forming Characteristics of Sintered Porous Metal (소결금속 의 성형 특성 및 마찰 상수 결정 에 관한 연구)

  • 오흥국;문재호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.2
    • /
    • pp.111-118
    • /
    • 1984
  • On the basis of plasticity theory for porous metal, an analysis of ring compression is carried out, employing the upper bound approach. The plastic flowability and the neutral radius of porous metal ring are calculated and deformation characteristics of power forging are obtained from this result. The experiments on ring compression are carried out for sintered iron porous metal with various relative densities under various friction conditions. A good agreement is observed between the shapes of the calculated curves and the experimental results from the ring compression test. The friction factor for powder metal forming can be determined not only from the relationship between reduction in height and reduction in internal diameter but independently from the relationship between reduction in height and relative density, if the initial relative density is known.

Relation between applied forces and surface characteristics on surface rolling in cast iron (주철의 표면로울링에서 가압력의 영향)

  • 육굉수;박병성;최재승
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.705-711
    • /
    • 1988
  • Surface rolling is one of the plastic deformation processes, which improves surface roughness and increases hardness. The surface rolling tool used in this experiment was specially designed by author for surface rolling on cast iron. The cutting feeds were 0.10mm/rev.and 0.30mm/rev.The applied forces of rolling were in the range of 10kgf to 30kgf with 5kgf differences. The results obtained are as follows. (1) In general the good surface roughness can be obtained with the applied force 25kgf according to surface roughness of the previous turning. (2) The hardness is mainly increased at the first rolling process and is more increased with the increasing applied forces. (3) The reduction of the diameter heavily depends on the original surface roughness. That is, the larger surface roughness is, the larger is the reduction is the reduction of diameter.

Structural and Optical Properties of ZnO/Glass Thin Films Grown by Radio-Frequency Magnetron Sputtering with a Powder Target (ZnO 분말 타겟을 스퍼터링하여 Glass 기판위에 증착한 ZnO 박막의 구조적, 광학적 특성)

  • Sun, J.H.;Kang, H.C.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.5
    • /
    • pp.394-401
    • /
    • 2009
  • This paper reports the structural and optical properties of ZnO/glass thin films grown by radio-frequency magnetron sputtering with a powder target. In contrast to ZnO ceramic target typically used, a ZnO raw powder target was sputtered in this study. ZnO grew with the (0002) preferred orientation along the surface normal direction. Initially, the surface of ZnO thin films was flat considerably and then it became rougher as the thickness increased. The optical transmittance was as high as 88% in the range of 400-1000 nm. The bandgap energy of 3.23 eV at the 220 nm thick sample was estimated.

Effect of Air Contents, Deicing Salts, and Exposure Conditions on the Freeze-Thaw Durability of the Concrete (콘크리트의 동결융해 내구성에 공기량, 제설제, 노출조건이 미치는 영향에 관한 연구)

  • Lee, Byung-Duk
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.107-113
    • /
    • 2010
  • In this study, the relative effects of low-chloride deicier(LCD) and two other deicing agents on the scaling of concrete were conducted in a series of tests at laboratory accordance with the ASTM C 672. The solutions concentration of deicers tested included 1, 4, 10%. Tap water was used as control. The amount of scaling was evaluated gravimetrically. As test result of deicer solution types, when applied to 4% solutions, surface scaling of concrete after 56 freeze-thaw cycles was produced significantly as about 9 times on LCD solution, as about 18 times on $CaCl_2$ solution, and as about 33 times on NaCl solution comparing with tap water. As test result of deicer solution concentrations, relatively low concentrations (of the 4% by weight) of deicer were produced more surface scaling than higher concentrations (of the 10% by weight) or lower concentrations (of the 1% by weight) of deicer. It show that the damaging concentration is of the order of 3~4% for previous research result. It appears that the mechanism of surface scaling is primarily physical rather than chemical. Also, the effect of chloride deicier types, freeze-thaw cycling, and air contents on the performance of concrete was experimentally investigated. The results show that the concrete specimens subjected to freeze-thaw cycling scaled more severely in exposure to deicing salt than those in non-exposure to deicing salt, weight losses of the specimens tested in exposure to deicing salt were twice as much as those tested in non-exposure to deicing salt. Relative dynamic modulus of elasticity of concrete specimens decreased more quickly in exposure to deicing salt than in non-exposure to deicing salt. Also, relative dynamic modulus of elasticity of concrete specimens in exposure to sodium chloride deicing salt was decreased more quickly comparing with exposure to LCD salt. It is also shown that the chloride contents according to concrete specimen depths was more largely in exposure to LCD salt. When concrete specimen is exposed to chloride deicing salts and freeze-thaw cycling, performance degradation in the entrained air concrete(AE concrete) retarded more considerably comparing with non-entrained air concrete(Non-AE concrete).

Microstructures and Mechanical Properties of API J55 steel with Heat treatment conditions and Alloying elements(B, Ti) (API J55강의 미세조직과 기계적 특성에 미치는 열처리 및 합금원소(B, Ti)의 영향)

  • Choi, Jong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.69-76
    • /
    • 2018
  • This study examined the effect of the heat treatment and alloying elements (B, Ti) on the microstructures and mechanical properties of API J55 steel. The experiments were carried out using various austenization temperatures ($880^{\circ}C$, $910^{\circ}C$, $940^{\circ}C$), cooling methods (water quenching, oil quenching) and tempering temperatures (none, $550^{\circ}C$, $650^{\circ}C$) with J55 and J55+B,Ti steels. The phase diagram and CCT curve were simulated based on the chemical compositions of the J55 and J55+B,Ti steels to predict the microstructures. The results showed that the A1 and A3 temperatures decreased and, as a result, the noses of the ferrite and bainite parts of the CCT curve moved to the right. Various microstructures were formed, namely martensite, bainite, ferrite and pearlite, in accordance with the heat treatment, which had an effect on the hardness, tensile strength and toughness. Martensite was formed after water quenching, but bainite and ferrite appeared after oil quenching with the J55 specimens. On the other hand, martensite was formed, regardless of the cooling method (water quenching, oil quenching), with the J55+B,Ti specimens, because of the improvement of the hardenability caused by the addition of boron. Therefore, the J55+B,Ti specimens exhibited much higher mechanical properties than the J55 specimens, even after the tempering treatment, since the addition of Ti caused fine precipitates to be formed, which inhibited grain growth at the recrystallization temperature.

Fabrication of a Ultrathin Ag Film on a Thin Cu Film by Low-Temperature Immersion Plating in an Grycol-Based Solution (글리콜 용매 기반 저온 치환 은도금법으로 형성시킨 동박막 상 극박 두께 Ag 도금층)

  • Kim, Ji Hwan;Cho, Young Hak;Lee, Jong-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • To investigate the plating properties of a diethylene glycol-based Ag immersion plating solution containing citric acid, silver immersion plating was performed in a range from room temperature to $50^{\circ}C$ using sputtered Cu specimens. The used Cu specimens possessed surface structure with large numbers of pinholes which were created with over-acid etching. The Ag immersion plating performed at $40^{\circ}C$ exhibited that the pinholes and copper surface were completely filled with Ag just after 5 min mainly due to galvanic displacement reaction, indicating the best plating properties. Subsequently, the surface morphology of Ag-coated Cu became rougher as the plating time increased to 30 min because of the deposition of silver nanoparticles created by chemical reduction in the solution. The specimen that its overall surface was covered with silver indicated the start of oxidation at temperature higher than around $50^{\circ}C$ in air as compared with pure Cu, indicating enhanced anti-oxidation properties.

플라스틱 기판상에 저온 증착된 IZO박막의 특성 연구

  • Jeong, Jae-Hye;Jeong, Yu-Jeong;Yun, Jeong-Heum;Lee, Seong-Hun;Lee, Geon-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.455-455
    • /
    • 2010
  • 차세대 디스플레이로 널리 알려져 있는 플렉서블 디스플레이는 휴대하기 쉽고, 깨지지 않으며, 변형이 자유로워 현재 우리 사회에 크게 주목받고 있다. 플렉서블 디스플레이의 구현을 위해서는 기존의 유리 기반 디스플레이 소자 기술에 더하여 플렉서블 기판소재에 적용 가능한 투명전도막 기술의 확립이 필요하다. 디스플레이 산업에서 주로 사용되는 투명전도막은 ITO (indium tin oxide) 및 IZO (indium zinc oxide)와 같은 투명전도성 산화물 박막 (TCO, transparent conducting oxide)이다. 그런데 플라스틱 기판이 굽힘 환경에 놓이게 되면 그 위에 증착된 산화물 박막이 쉽게 파손될 수 있다. 따라서 플렉서블 디스플레이 기술에 있어서 변형에 따른 TCO 박막의 파괴 거동에 대한 연구가 필수적이다. 본 연구에서는 PET (polyethylene terephthalate) 기판 상에 증착된 IZO 박막의 반복 굽힘 시 계면구조 변화에 따른 파괴거동을 조사하였다. 플라스틱 기판의 사용을 위해서는 산소 및 수분의 투과 방지막이 필요하며 본 연구에서는 투과 방지막 (또는 보호막)으로서 $SiO_x$ 박막을 적용하였다. IZO 박막은 $In_2O_3$ - 10 wt% ZnO 타겟을 사용하여 RF magnetron sputtering법으로 $100^{\circ}C$ 미만에서 저온 증착하였다. 보호막으로 사용되는 $SiO_x$ 박막은 HMDSO (hexamethyldisiloxane)와 Ar 및 $O_2$ 혼합기체를 이용하는 PECVD 방법으로 합성하였다. 변형에 따른 TCO 박막의 파괴 거동을 조사하기 위하여 반복 굽힘 시험 (cyclic- bending test)을 실시하였다. 반복 굽힘 시험 중 실시간으로 IZO 박막의 전기저항 변화를 측정하여 박막의 파괴 거동을 모니터링 하였다. 시편 A (135 nm-thick IZO/PET), B (135 nm-thick IZO/ 90 nm-thick $SiO_x$/PET), C (135nm-thick IZO/ 300 nm-thick $SiO_x$/PET)에 대하여 곡지름 35mm, 1000회 반복 굽힘을 실시하여 변형 중의 전기저항 변화를 조사하였다. 그리고 굽힘 시험 완료 후, FE-SEM을 이용한 시편 표면형상 관찰을 통하여 균열생성 정도를 관찰하였다. 반복 굽힘 시험 결과, A 와 C 시편의 경우, 각각 반복 굽힘 20회, 550회에서 급격한 전기저항의 증가가 관찰되었다. 그러나 B 시편의 경우, 1000회 반복 굽힘 후에도 전기저항의 변화는 나타나지 않았다. 이와 같이 반복 굽힘에 의한 IZO 박막의 파괴 거동 변화는 IZO 박막과 기판의 계면구조변화에 기인한 것으로 해석된다. IZO 박막과 기판의 계면에 $SiO_x$ 층을 삽입함으로써 계면 접합강도가 향상되었을 것으로 추측된다. 따라서 변형에 대한 파괴 저항 특성이 우수한 투명전도성 산화물 박막의 형성을 위해서는 적절한 계면구조 제어를 통한 계면 접합 특성의 향상이 필요하다.

  • PDF

A Study on the Strength Characteristics and Failure Detection of Single-lap Joints with I-fiber Stitching Method (I-fiber 스티칭 공법이 적용된 Single-lap Joint의 강도 특성 및 파손 신호 검출 연구)

  • Choi, Seong-Hyun;Song, Sang-Hoon;An, Woo-Jin;Choi, Jin-Ho
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.317-322
    • /
    • 2021
  • When a complex load such as torsion, low-speed impact, or fatigue load is applied, the properties in the thickness direction are weakened through microcracks inside the material due to the nature of the laminated composite material, and delamination occurs. To prevent the interlaminar delamination, various three-dimensional reinforcement methods such as Z-pinning and stitching, and structural health monitoring techniques that detect the microcrack of structures in real time have been continuously studied. In this paper, the single-lap joints with I-fiber stitching process were manufactured by a co-curing method and their strengths and failure detection capability were evaluated. AE and electric resistance method were used for detection of crack and failure signal and electric circuit for signal analysis was manufactured, and failure signal was analyzed during the tensile test of a single-lap joint. From the experiment, the strength of the single lap joint reinforced by I-fiber stitching process was improved by about 44.6% compared to the co-cured single lap joint without reinforcement. In addition, as the single-lap joint reinforced by I-fiber stitching process can detect failure in both the electrical resistance method and the AE method, it has been proven to be an effective structure for failure monitoring as well as strength improvement.