• Title/Summary/Keyword: 로브

Search Result 122, Processing Time 0.021 seconds

Optimization Design of the Clinch Stud using the Finite Element Analysis and the Taguchi Method (유한요소해석과 다구찌 방법을 이용한 클린치 스터드의 설계 최적화)

  • Byun, Hong-Seok;Kim, Gang-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3135-3141
    • /
    • 2013
  • This study derives the optimal conditions for design parameters of clinch stud with high torque resistance and bonding force by using FE simulation and Taguchi method. Maximum forming load and filled rate of material are considered as objective functions. Height and depth of groove with diameter and depth of lobe are chosen as design parameters. These control factors and the friction considered as noise factor are combined by orthogonal array. Forming load and filled rate are evaluated through the simulation. Simulation results are analyzed by using the ratio of signal to noise through Taguchi method. From these results, their optimal combination conditions are proposed. In the order of the most important parameter which affects filled rate, there are the height of lobe, the height of groove, the radius of lobe and the depth of groove.

Optimal Design of Gerotor with Combined Lobe Profiles (Ellipse 1-Elliptical Involute-Ellipse 2) (타원 1-타원형 인벌루트-타원 2 로브 형상의 제로터 최적 설계)

  • Kwak, Hyo Seo;Li, Sheng Huan;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1237-1244
    • /
    • 2015
  • A gerotor can be manufactured in a miniature size because it has a high discharge per cycle and a simple structure. Gerotors are widely used for the lubrication oil of an engine and as the hydraulic source of an automatic transmission. Recently, improvements in fuel efficiency and noise reduction have come to the fore in the automobile industry, and it has been necessary for better fuel efficiency to continuously improve the flow rate and noise of internal gear pumps through the optimal design of the gerotor and port shape. In this study, gerotors were generated based on the equations derived for a lobe shape with multiple profiles (ellipse 1-elliptical involute-ellipse 2). The ranges of the design parameters were considered to prevent a cusp and loop. In addition, the optimal lobe shape was obtained by determining the influence of the lobe shape on the performances (flow rate, irregularity, etc.), according to the values of the design parameters.

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.

A Study on the Beam-forming of the Linear Array Antenna using Grating Lobe (Grating Lobe를 이용한 선형 배열 안테나의 Beam-forming에 관한 연구)

  • 신정록;송우영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.806-812
    • /
    • 2000
  • In this paper, we theoretically studied on the large antenna array whose element had wider than one wavelength. And we also verified the adaptedness through the experiments. Using grating lobes, we could make antenna have sharp HPBW. Not only HPBW but also SLL could be controlled by giving optimal space for antenna array. In order to verify this method, we designed 4 horn antenna array and measured the radiation patterns at 9 GHz. Each horn antenna has the dimension of 64.3$\times$82.5$\textrm{mm}^2$ and HPBW of 27$^{\circ}$. The space between antennas is longer than one wavelength so that it may have the grating lobes in visible region. As a result of experiments, we could get HPBW of 4.3$^{\circ}$, 3.3$^{\circ}$ and 1.7$^{\circ}$when giving 2.5λ, 2.7λ and 3.0λ of the spacing respectively. We concluded this could be useful making the antenna with narrow HPBW.

  • PDF

Analysis of the Ultrasonic Beam Profile Due to Variation of the Inter-Element Spacing for the Phased Array Transducer (페이즈드 어레이 트랜스듀서에 있어서 구성 압전소자의 간격 변화에 따른 초음파 빔 전파 특성 해석)

  • Choe, Sang-U;Lee, Jun-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.972-981
    • /
    • 2000
  • The phased array transducer has two distinct advantages. One is rapid scanning comparing with the conventional mechanical or manual scanning system. Therefore, output image is represented in real-time. The other is the dynamic focusing and the dynamic steering of ultrasonic beam. Only the delay times that are controlled electrically are used to focus and to steer beam without any lenses or wedges. In this study, the profile of the ultrasonic beam for the phased array transducer has been simulated in the Huygens principle with varying the inter-element spacing of the linear phased array transducer. From the result of this study, it was found that the ultrasonic beam spread wider as the inter-element spacing was decreased. However, the focusing effect was improved, even when the number of the element was not big. In addition, there was grating lobes that are constructed when the inter-element spacing is more than half wavelength. However, this grating lobe has lower amplitude than the main lobe.