• Title/Summary/Keyword: 렌즈

Search Result 2,765, Processing Time 0.028 seconds

Changes of Thin Film Coating on Polymer Lenses with Varying Temperature (온도에 의한 고분자 렌즈의 재질별 코팅 박막의 변화)

  • Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: To observe changes of coatings and lens materials with varying temperature to understand effect of temperature on plastic lens. Methods: In this study, three lenses of different refractive indices (2 of thiourethane oriented lenses, an allyl diglycol carbonate oriented lens) were exposed to high temperature (50, 80, and 100 degree) for 5 hours and changes of individual coating (anti-refractive coating, hard coating, and water repellent coating) were measured. Results: As a result, high-refractive index lenses did not exhibit significant variation of hardness. However, hardness of mid-refractive index lens were decreased when exposed to high temperature and destructions of hard coating layer was inferred. Surface contact angles of lens were decreased with increasing temperature and water repellent coating layer were damaged at higher than 80 degree. Conclusions: Multi including water repellent coatings on all three lenses with different refractive indices were damaged when exposed to at or higher than 80 degree. The degree of changes in mechanical and physical properties were depended on polymer material type.

A Study on the Residual Astigmatism Appeared after Operating ICL Lens (ICL 렌즈 시술 후 나타나는 잔류난시에 대한 연구)

  • Kim, Dook-Hoon;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.155-160
    • /
    • 2008
  • Purpose: To develop a program for analyzing the condition of implanted ICL lenses in case the residual astigmatism appears after the implantation. Methods: From analyzing the measured residual astigmatism after operating ICL lens, we could induce formulas that produce the rotating angle and the corresponding MR prescription of the implanted ICL lens. Using the Delphi 6.0 language, we could develop a program by which we conveniently confirm, in the window screen visually, the rotating angle and the corresponding MR prescription of the implanted ICL lens calculated by these formulas. Results: We induced formulas that produce the rotating angle and the corresponding MR prescription of the implanted ICL lens by analyzing the measured residual astigmatism after operating ICL lens and developed a program which can analyze the condition of the implanted ICL lens. By this program we could easily analyze the condition of the implanted ICL lens. Conclusions: Judging from the results of applying this program to many clinical cases, we could conclude that this program is very effective in analyzing the condition of implanted ICL lenses.

  • PDF

Changes of the Plastic Lens Properties Caused by Etching of the Coating Films (코팅막 식각으로 인한 플라스틱 렌즈의 특성 변화)

  • Moon, Byeong-Yeon;Hwang, Ki Ju;Lee, Yoon Jeong;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2010
  • Purpose: We investigated the changes of plastic lens after etching of coating films by comparing uncoated lens. Methods: CR-39, middle index and high index lenses of 0 (zero) diopter were etched at $80^{\circ}C$ and room temperature using a coating remover, and then changes of refractive power, transmittance and surface morphology were investigated. Results: There were no differences in refractive power and transmittance between uncoated and etched lenses. The etching rate was similar in both CR-39 and middle index lens, but in the case of high index lens, it was slower and less steady than the others. From the SEM observation of lens surface, etching damage was found out on the surface of etched lens. It was shown the least damage in middle index lens but the most damage in high index lens. Conclusions: If the etching of coating films is demanded on condition that the surface of ophthalmic lenses are not damaged, a using of most adequate coating remover based on lens material should be considered, and a caution for proper etching conditions is required.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

A Study on Improvement of Wettability and Comfort in Contact lens with Hyaluronic acid (Hyaluronic acid 함유 콘택트렌즈의 습윤성과 착용감 향상 효과 연구)

  • Kim, Hyun Jung;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.255-264
    • /
    • 2011
  • Purpose: To study the effect of hyaluronic acid(HA), which was widely used in artificial tears, multi-purpose solution(MPS), cosmetics, and drug acting on the musculo-skeletal system, in wettability and comfort of contact lens, we compared HA including lens(+HA) with HA excluding lens(-HA) by clinical evaluation. Methods: During four weeks, the selected 28 university student volunteers who did not have any eye disease wore +HA contact lens on their right eyes, and -HA contact lens on their left eyes, and then compared right eyes to left eyes as control. After prescribing by spherical equivalent calculation, over-refraction by auto-refractometer, and contact lens wearing for two weeks and four weeks, tear evaluation, the anterior of eyes examination, fitting convenience evaluation, surface wetting test, surveys were checked up. Results: Compared with the control group (-HA contact lens), +HA contact lens provided better wetting properties. The amount of released tear in -HA contact lens group became less in four weeks than before, but that in +HA contact lens group showed no significant difference from the initial one. In terms of the redness in eye, there was no significant difference between +HA and -HA contact lens groups. Fitting of +HA contact lens on eye was much easier than the control, -HA contact lens. From the results of survey, comfort, wettability, ease of cleaning, and dryness of eye in +HA contact lens group were generally better than those of -HA group, but redness and contact lens handling showed little difference. Conclusions: The addition of HA in soft contact lens(+HA) may enhance the wettability of lens during lens wearing, resulted in the better comfortable wearing of lens eventually.

The Clinical Examination of Netspeg Lens for Good Visual Acuity (시력 개선을 위한 Netspeg 렌즈의 임상적 검증)

  • Kim, Douk-Hoon;Bae, Han-Young;Kim, Sun-Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2006
  • The aim of this study was performed the clinical test using Netspeg lens for good visual acuity on subjects with abnormal refraction status. The subjects of one hundreds adults (fifty males, fifty females, mean=21 years, range=19 to 24) were recorded. The subjects were researched the history including the systemic health, medication, genetics, allergy, systemic disease and ocular disease. The refraction test was recorded the monocular and binocular using objective method. Visual acuity was performed the binocular status using the Netspeg lens and CR-39. Stereopsis test was performed the titmus fly and TNO at near distance using Netspeg lens and CR-39. The P-VEP test was used the 16 pattern size(Bausch Lomb, production in USA) with three channels. Also Subjects viewed the p-vep stimulus with binocular vision through the corrected visual acuity using the Netspeg lens and CR-39. The contrast sensitivity test was performed the contrast sensitivity chart(pelli-Robertson, USA) at 1m distance using the Netspeg lens and CR-39. The ultrastructure of surface on the Netspeg lens and CR-39 was observed the SEM(JMS-5800, made in Japan). The results of this study was as follows: 1. In corrected visual acuity of abnormal refraction using the Netspeg lens and CR-39, the Netspeg lens wearer were acquired the good visual field and clear visual acuity comparative to CR-39 wearer in the subject vision test. however the comfort of visual acuity was similar results in the Netspeg lens and CR-39. Also the subjects of Netspeg lens wearer was good visual acuity more than CR-39 wearer and in the analysis of P-VEP, the amplitude of wave on Netspeg lens used appears to be better through the CR-39(p>0.5). Besides, on the contrast sensitivity, the Netspeg lens wearer was good results than CR-39. The value on stereopsis with TNO by Netspeg lens wearer was better than CR-39 in results. However, in the stereopsis test with Titmus, the Netspeg lens and CR-39 wearer was similar results. 2. The ultrastructure of Netspeg lens surface was the smooth and fine shape more than CR-39. Also, Netspeg lens have a fine line structure in ultrastructure. In conclusion, the results of this study conformed that the surface ultrastructure of Netspeg lens used is more specific pin hole design structure than CR-39. This study indicated that the vision of Netspeg lens used have a better than CR-39 in the corrected visual acuity for abnormal refraction eye. Therefore, In this paper, we suggested that the ultrastructure and line structure of Netspeg lens was related to good visual function. However the visual function of the aspheric Netspeg and ultra waterproof Netspeg lens was similar results.

  • PDF

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

명품금형으로 폰카메라 렌즈 금형 양산 '호평'

  • 한국광학기기협회
    • The Optical Journal
    • /
    • s.133
    • /
    • pp.14-15
    • /
    • 2011
  • 국내에서 폰카메라용 렌즈 금형의 독보적인 기술력을 보유한 한국와이다(대표 장해산)는 카메라폰용 8Cavity와 호환이 되는 16Cavity 렌즈 금형을 국내 최초로 개발했다고 밝혔다. 순수 국내 기술로 개발된 호환형의 8 & 16Cavity 렌즈 금형은 렌즈 생산을 2배 이상 늘릴 수 있어 짧은 시간 내에 대량 양산이 가능할뿐만 아니라 수지의 양도 기존의 절반으로 줄여 비용절감 효과도 가져왔다.

  • PDF

모으는 빛 확대하는 빛 - 마이크로 렌즈의 최신 동향

  • 이카 겐이치
    • The Optical Journal
    • /
    • v.14 no.6 s.82
    • /
    • pp.72-80
    • /
    • 2002
  • 필자는 2차원 어레이 형대 마이크로렌즈의 방식을 1979년에 제안했다. 초기에는 학회에 발표 할 때마다 이처럼 작은 렌즈를 어디에 쓸 것인가 라는 질문을 끊임없이 받았다. Microlens라는 학술용어도 없어 학회지에서 사용도 허가되지 않았을 정도였다. 그 뒤 광일렉트로닉스의 학술, 산업의 발전에 따라 종종 마이크로렌즈 제작법이 고안되어, 여러 가지 응용분야에 적용이 확대되었다. 본 내용에서는 이와 같은 소형 마이크로렌즈의 제작법과 응용 등에 대해 기초

  • PDF