• Title/Summary/Keyword: 레진 주조

Search Result 26, Processing Time 0.017 seconds

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

Comparison of internal adaptation of removable partial denture metal frameworks made by lost wax technique and printing technique of pattern using CAD (Lost wax technique과 CAD를 이용한 pattern의 프린팅 방식으로 제작된 가철성 국소의치 금속구조물의 적합도 비교)

  • Choi, Wonjun;Woo, Yi-Hyung;Kim, Hyeong-Seob;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Lost wax technique of casting wax patterns has been used principally to make metal frameworks of removable partial dentures. Since the development of digital technology and CAD, metal frameworks can be built through digital surveying and framework designing. Many cases proved that resin patterns made by CAD printing method were well adapted to internal oral structure and final metal frameworks also showed good internal adaptation as well. The metal frameworks of a removable partial denture were made by both lost wax technique and CAD technique and were applied to a patient with severe alveolar bone loss. Using CAD data and fit checker, internal adaptation of both metal frameworks were evaluated by comparing the gap between surveyed crown and its structure. This study is to prove that metal frameworks by both techniques showed adaptation that can be applied in clinical field.

RPD framework fabrication using computer-aided design (CAD) and rapid prototyping (Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례)

  • Park, Seon-Ah;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Nowadays, digital dentistry is generally applied to prosthodontics with fabrication of inlays or any other fixed prostheses by utilizing CAD/CAM (computer-aided design/computer-aided manufacturing) technology and intraoral scanner. However, in fabricating removable prosthesis, there are some limitations for digital technology to substitute conventional casting method. Therefore, approaching removable prostheses fabrication with CAD/CAM technology would be a meaningful trial. In this case report, Kennedy class III mandibular edentulous patient who was in need of increasing the vertical dimension of occlusion was treated with removable partial denture using CAD and rapid prototyping technique. Surveying and designing the metal framework of the partial denture was performed with CAD, and sacrificial plastic pattern was fabricated with rapid prototyping technique. During the follow up period of nine months, the removable partial denture has provided satisfactory results in esthetics and function.

COMPARISON FOR THE RETENTION OF CASTING CROWN AND CEMENT THICKNESS FOLLOWING VARIOUS CEMENTS (수종의 세멘트에 따른 주조금관의 유지력 및 세멘트 두께의 비교)

  • Lee, Cheong-Hee;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 1994
  • The purpose of this study was to evaluate the effect of various cements on the retention of casting crown and the cement film thickness. To evaluate the retention of crown, thirty maxillary premolars were used and prepared to largely same dimension. According to the routine method, Non-precious metal crowns were made. The teeth and the metal crowns were divided into three groups and cemented under 5kg static pressure. Group I was composed of 10 teeth and 10 metal crowns and was cemented with zinc phohsphste cement. Group II was composed of 10 teeth and 10 metal crowns and was cemented with Panavia-EX cement. Group III was composed of 10 teeth and 10 metal crowns and was cemented with All-Bond & composite resin cement. After 5 days, the cemented specimens were mounted and the failure loads were measured by an Instron Universal Testing Machine. To evaluate the cement film thickness. 5 metal teeth and 5metal crowns from a prepared maxillary premolar were made. Two marks were flawed on the margin part of each surface at 4-surfaces of each specimen(one mark : crown, the other : metal tooth) and were measured the width with SEM photograph(80 sheets) before and after cementation(Panavia-EX, All-Bond cement, & ZPC) was made. Differences of the widths of marks between before and after were measured, and differences from 4-surfaces of a specimen cemented with a cement were measured and calculated. The results were as follows ; 1. There was a statistically significant difference between the failure loads of group III and the others(p<0.05). 2. There was a statistically significant difference between the cement film thickness of group III and the others(p<0.05).

  • PDF

A Study of the Comparison of Microleakage according to the Types of Cement on the Cast Post and Core (주조 포스트코아에서 시멘트 종류가 미세누출에 미치는 영향)

  • Nam, Ki-Young;Lee, Cheong-Hee;Cho, Kwang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The purpose of this study was to compare the microleakage at the interface of cast post and tooth according to the type of cement. Forty anterior teeth with single root were used. The teeth were cut 2 mm coronal from the cementoeamel junction and chamfer finish line was made on 1 mm coronal from the cementoeamel junction. After the routine endodontic treatment, post space was prepared using #5.5 Parapost drill to a depth of 7 mm. After the pick up impression, core building was made to 3 mm of clinical crown with burnout wax, then post and core was cast with nonprecious metal. The teeth were divided into four groups of ten each. In Group I, post and core were cemented with Fleck's(Zinc phosphate cement) In Group II, post and core were cemented with Fuji I(Glass ionomer cement) In Group III, post and core were cemented with Superbond C & B(Composite resin cement) In Group IV, post and core were cemented with Panavia 21(Composite resin cement) All cemented teeth were stored in normal saline at $37^{\circ}C$ for 7 days and thermocycled from $5^{\circ}C$ to $55^{\circ}C$ for 500 cycles with a dwell time of 30 seconds. After thermocycling, teeth were immersed in 1% Basic fuchsin dye for 48 hours. All 40 teeth were then embedded in the epoxy resin and cut buccolingually with a cutting instrument. The degree of penetration of dye at interface was graded on a scale of 0 to 4 using a stereomicroscope at 25 to 40 times magnification. Through the findings of this study, the following conclusion were obtained. 1. All the groups showed the microleakage at the interface of cast post core and tooth. 2. Group I showed the highest microleakage score among the groups with a significant difference(p<0.05). 3. Group II showed higher microleakage score than Group III and Group IV with a significant difference(p<0.05). 4. Group IV showed the lowest microleakage score but there were no significant difference with Group III(p>0.05).

  • PDF

THE FILM THICKNESS AND RETENTION OF CAST CROWN USING ADHESIVE RESIN CEMENTS (접착성 레진 시멘트를 이용한 주조관의 피막후경과 유지력에 관한 연구)

  • Jung Young-Wan;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.437-443
    • /
    • 1992
  • This study was performed to investigate the availability of adhesive resin cement for luting agent of cast crown. The resin cements used in this study were Panavia-Ex(Kuraray Co., Japan) and C & B-Metabond (Parkell Bio-Materials U.S.A.). Zinc phosphate cement was Flecks zinc cement(Mizzy Inc., U.S.A.) The film thickness of cast crown at gingival margin, lateral wall and occlusal surface was observed with measuring microscope(Modek MXT 70 Matsuzawa Seiki Co., Japan) and the retention of cast crown was measured with Instron Universal Test Machine (Instron Engineering Co., U.S.A.) The results were as follows : 1. The value of retention of cast crown was the highest in the use of Panavia-EX, followed by C & B-Metabond and 2inc phosphate cement, respectively. 2. There was no difference in film thickness among the three cements, but the film thickness in all cements was highest at occlusal surface.

  • PDF

Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer (합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향)

  • Lee, Yun-Hui;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Purpose: The object of this study was to determine if the low-priced alloy and metal UCLA abutment could be available for manufacturing bar-retained framework of implant prosthesis. Materials and methods: Bar structure was classified into 4 groups, The specimen of group 1 and 2 were based on casting high noble metal alloys and noble metal alloys with gold UCLA abutment. The specimen of group 3 and 4 were based on casting noble metal alloys and base metal alloys with metal UCLA abutment. Cast bar structure was installed in an acrylic resin model and only the screw on the hexed abutment side was tightened to 20 Ncm. On the opposite side, vertical discrepancy was measured with stereo microscope from front, back, and lateral side of the implant-abutment interface. One-way ANOVA was performed to analyze the marginal fit discrepancy. Results: One-way ANOVA test showed significant differences among all groups ($P$<.05) except for Group 1 and 3. Among them, difference between Group 1 and 2 was noticeable. Measured vertical discrepancies were all below $70{\mu}m$ except to Group 2. Conclusion: Base metal alloy and metal UCLA abutment could be used as an alternative to high-priced gold alloy for implant bar-retained framework.

Evaluation of static fracture resistances and patterns of pulpless tooth restored with poly-ether-ketone-ketone (PEKK) post (Poly-ether-ketone-ketone (PEKK) 포스트로 수복한 근관 치료 치아의 정적 파절 저항성 및 파절 형태에 관한 평가)

  • Park, Ha Eun;Lee, Cheol Won;Lee, Won Sup;Yang, Sung Eun;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.127-133
    • /
    • 2019
  • Purpose: The purpose of present study was to investigate fracture strength and mode of failure of endodontically treated teeth restored with metal cast post-core system, prefabricated fiber post system, and newly introduced polyetherketoneketone (PEKK) post-core system. Materials and methods: A total of 21 mandibular premolar were randomly grouped into 3 groups of 7 each according to the post material. Group A was for metal cast post core; Group B for prefabricated glass fiber post and resin core; and Group C for milled PEKK post cores. All specimens were restored with metal crown. The fracture strength of each specimen was measured by applying a static load of 135-degree to the tooth at 2 mm/min crosshead speed using a universal testing machine. After the fracture strength measurement, the mode of failure was observed. The results were analyzed using Kruscal-Wallis test and post hoc Mann-Whitney U test at confidence interval ${\alpha}=.05$. Results: Fracture resistance of PEKK post core was lower than those of cast metal post and fiber reinforced post with composite resin core. In the aspect of fracture mode most of the root fracture occurred in the metal post core, whereas the post detachment occurred mainly in the fiber reinforced post. In the case of PEKK post core, teeth and post were fractured together. Conclusion: It is necessary to select appropriate materials of post for extensively damaged teeth restoration and clinical application of the PEKK post seems to require more research on improvement of strength.

Valplast$^{(R)}$ flexible removable partial denture for a patient with medically compromised conditions : a clinical report (전신적 질환자 및 예후가 불량한 환자에서 Valplast$^{(R)}$ 탄성 국소의치의 적용)

  • Choi, Bohm;Kim, Seong-Hun;Lee, Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.295-300
    • /
    • 2009
  • Statement of problem: As the number of elders is growing with the advancement of medicine, partially or fully edentulous patients have increased. Medically compromised conditions are common in the older population so that it should be taken into account in prosthetic treatment planning as well as their economic conditions. In the older patients, removable prosthesis has been preferred to implant prosthesis. However, cast metal based removable partial dentures also has several limitations. Purpose: In this report, we present several cases of Valplast$^{(R)}$ flexible denture which were fabricated in patients who had medically compromised conditions or whose remaining teeth showed a relatively poor prognosis. Results & Conclusion: This article describes an alternative treatment for a partially edentulous patient with mouth opening limitation, after cancer surgery, compromised general condition and questionable remaining teeth. In these patients, Valplast$^{(R)}$ flexible denture was used because of its unique characteristics and the results were all satisfactory. Patients had 1-2 check-up and there were no postoperative pain or fracture of denture up to now.

A SURVEY ON THE PREOPERATIVE CONDITIONS OF ENDODONTICALLY TREATED FIRST MOLARS IN CHILDREN AND ADOLESCENTS (소아청소년기에 치수치료를 받은 제1대구치의 술전 상태 조사)

  • Lee, Soon-Young;Lee, Kyung-Ho;Noh, Hong-Seok;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.4
    • /
    • pp.376-382
    • /
    • 2011
  • In clinical dentistry, it is not difficult to meet the permanent first molars with severe coronal caries lesions in children or adolescents. The circumstances surrounding the first molars of children and adolescents are so immature and imperfect compared with those of adults. So we thought it significant to understand the status of these teeth at the moment of endodontic treatment and immediate cause of it. 106 patients with 135 permanent molars necessitating endodontic treatment in childhood and adolescence were included in this study, and the dental records and radiographs were examined. 1. The mean age was 11.9 year (male 11.5, female 12.5) and the result shows significant difference between gender(p<0.05). The mandibular teeth took more than half percentage than maxillary teeth. 2. Of 135 teeth, 45.2 percent of teeth had history of dental treatment previously and 16.3 percent of teeth showed necessity of re-endodontic treatment. 3. Of 73 teeth, 22 teeth had mesial-wall cavity causing endodontic treatment, 39 had occlusal cavity, and 12 had distal cavity.