• Title/Summary/Keyword: 레이저 경화

Search Result 128, Processing Time 0.025 seconds

Effects of acupuncture and low level laser acupuncture therapy (LLLAT) at Yolgyol (LU7), Yogu (LR5) in hyperlipemia rats induced by high rat diet (고지혈증 유발 백서에서 열결 ${\cdot}$ 여구에 대한 침자 및 강도별 레이저조사가 체중, 식이효율, 지질대사 및 동맥경화지수에 미치는 영향)

  • Na, Chang-Su;Youn, Dae-Hwan;Cho, Myung-Rae;Kang, Ja-Don
    • Korean Journal of Acupuncture
    • /
    • v.24 no.1
    • /
    • pp.113-129
    • /
    • 2007
  • Objectives : This research was performed to investigate the effect of acupuncture using invasive low level laser therapy (LLLT) at Yolgyol (LU7) + Yogu (LR5) on weight gain, food intake, food efficiency, lipid metabolism, atherogenic index, HTR (HDL-cholesterol to total cholesterol ratio) and morphological change of hepatic tissue in hyperlipdemia rats. Methods : Experimental groups were divided into high fat diet group (Control group), high fat diet and acupuncture therapy group at LU7 + LR5 (AT group), high fat diet and acupuncture group using 10 mW LLLT at LU7 +LR5 (LA10 group), high fat diet and acupuncture group using 20 mW LLLT at LU7+LR5(LA20 group), high fat diet and acupuncture group using 60 mW LLLT at LU7 + LR5 (LA60 group), once per 3 days during 9 weeks. Results : Body weight was decreased significantly in AT and LA20 groups compared with Control group. Food intake was increased significantly in LA60 group compared with Control group. Food efficiency was decreased significantly in LA10, LA20 and LA60 groups compared with control group. In the lipid metabolism, total cholesterol was decreased significantly in AT, LA10, LA20 and LA60 groups, triglyceride was decreased significantly in LA10, LA20 and LA60 groups, TG/HDL-cholesterol ratio was decreased significantly in LA 60 group compared with control group. In the morphological change, hepatic tissue were not showed balloning degeneration and irregular arrangement of hepatic cell in LA10 and LA20 groups with control group. Conclusions : Acupuncture using LLLT at LU7+LR5 can manage hyperlipemia by controlling body weight, food intake, food efficiency ratio and lipid metabolism.

  • PDF

A study on the application of optical fiber sensors to smart composite structures (지능형 복합재 구조물에 대한 광섬유센서의 적용에 관한 연구)

  • Jang, Tae-Seong;Kim, Ho;Lee, Jung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.15-24
    • /
    • 1996
  • In this study, as a part of the basic study for the application of optical fiber sensors to smart composite structures, the integrity of optical fiber sensors embedded within the composite structures was examined and then the laser signal transmitted through optical fiber sensors during the deformation of host structures was investigated. Firstly, it was found that bending test could be substituted for tensile test by comparing cumulative failure distribution based on weakest link theory and introducing the correction factor. Weibull parameters were obtained through the experiments and the correction factor was found to be applied to cumulative failure distribution derived from bending test. The integrity of embedded optical fiber sensors due to the thermal effect was evaluated by the comparison of the mean tensile strengths of cured and uncured optical fibers. Secondly, relationships between stress-strain curve obtained in tensile test of composite laminate and the intensity of laser signal transmitted through embedded optical fibers were examined and the possibility of the effective damage detection using optical fiber sensors was studied.

  • PDF

A Scanning Electron Microscopic Study on the Effect of Nd:YAG Laser Irradiation on the Sclerotic Dentin (Nd:YAG레이저조사가 경화상아질에 미치는 영향에 관한 주사전자현미경적 연구)

  • Kim, Moon-Hyeon;Shin, Keum-Back
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.4
    • /
    • pp.397-410
    • /
    • 1999
  • In order to obtain the basic data concerning the optimal parameters in using Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity, the author prepared 3 sections of sound dentin and 10 sections of sclerotic dentin with thickness of $0.5mm{\pm}0.1mm$ from human extracted teeth of anteriors and premolars, and applied the laser energy from a fiberoptic delivered, free running, pulsed Nd:YAG laser (wavelength 1064nm, pulse duration $120{\mu}sec$, fiber diameter $320{\mu}m$) to surfaces of sound and sclerotic dentin sections for 1 second with contact/unidirectional moving mode of the fiber under speed of 3mm~4mm/sec and parameters of 0.5W/10Hz, 1.0W/10Hz, 1.5W/10Hz, 2.0W/10Hz: $62J/cm^2$, $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. The author comparatively evaluated the characteristics of ultrastructural changes on surfaces of sound and sclerotic dentin sections irradiated by the pulsed Nd:YAG laser using the scanning electron microscopy. A fairly ill-defined bordered surface of partially closed and melted dentinal tubules can be seen on the scanning electron microscopic feature of the sound dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sound dentin surface extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$. While, a fairly well-defined bordered surface of partially closed and melted dentinal tubules with thickened peritubular dentin can be seen on the scanning electron microscopic feature of the sclerotic dentin surface irradiated by the pulsed Nd:YAG laser with energy density of $62J/cm^2$. The physical modification of sclerotic dentin surface of a fairly rough, shallow depression with many cracks, thickened peritubular dentin and structureless dentinal tubules extensively occurred depended on the increase of energy density from $62J/cm^2$ to $124J/cm^2$, $187J/cm^2$, $249J/cm^2$ compared to those of sound dentin surface irradiated by the pulsed Nd:YAG laser under the same parameters. Therefore, it is recommended that the pulsed Nd:YAG laser as a therapeutic modality to dentinal hypersensitivity should be applied with the less energy density than $62J/cm^2$ on the sound dentin surface, and its energy density on the partially sclerotic dentin surface should be lower than that on the sound dentin surface to preserve tooth from unnecessary excessive structural destruction.

  • PDF

Removal Methods of Paint Pollutants on the Stone Cultural Heritage using Poultices (습포제를 이용한 석조문화재의 페인트 오염물 제거기법 연구)

  • Lee, Joo-Wan;Ham, Chul-Hee;Kim, Sa-Dug;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.421-430
    • /
    • 2009
  • This research was carried out focusing on the urgent treatment and related studies for paint scribbling on Samjeondobi Monument (Historic Sites No. 101) in 2007. Before the preliminary test, the paint lacquer used on the surface of Samjeondobi Monument was analyzed. The paint lacquer turned out to be the paint lacquer spray composed of $Pb_3O_4$ used for the red pigment in the market. It was proved that the poultice used with the organic solvent was the best way to remove the paint pollutants following the preliminary test for the removal of paint pollutants which was performed with various removal methods by the laser, etc. However, the removing the paint pollutants was found in difficulty in contrast to the preliminary tests because the paint on the spot was hardened so rapidly over time that there was difference from the situation of the laboratory. For that problem, the poultice method with ethylene dichloride of main component from Remover (goods in the market) was the most efficient, therefore the pollutants were removed with the solution of alkyds resin and nitrocellulose and the rest part was removed by the $Laponite^{(R)}$ RD.

  • PDF

Investigation of Regraphitization during Cam Shaft Remelting (캠 샤프트 재용융 처리시 재흑연화 현상에 관한 연구)

  • Oh, Young-Kun;Kim, Gwang-Soo;Koh, Jin-Hyun
    • Korean Journal of Materials Research
    • /
    • v.8 no.7
    • /
    • pp.648-652
    • /
    • 1998
  • TIG remelting was performed to harden the surface of automobile earn shaft. Multipass remelting was conducted in longitudinal direction under argon gas atmosphere. The microstructure of as-east earn shaft was gray iron which consisted of flake graphite and pearlitic matrix. The remelted area had microstructue of both fine pearlite and ledeburite structure that consisted of globular austenite and $Fe_3C$. Hardness for as-cast earn shaft had HRc 25~28, however it increased at remelted area to HRc 53~55. Black line was found at heat affected zone next to the fusion line, that is remelt area of previous pass, during multipass remelting. Black line was identified as graphite, which was transformed from $Fe_3C$. in the ledeburite structure. It is observed that all graphites were nucleated at $Fe_3C$. and matrix interface. High density energy laser remelting process was also applied to verify whether black line could be eliminated. However, black line was still existed as observed in TIG remelting process. Regraphitization was simulated on the ledeburitic structure specimen using Gleeble 1500 with conditions of 1100 and 100$0^{\circ}C$ for 0.5, I, 3, 5 and 1Osee. From the fact that graphite was formed even at the simulation condition of 100$0^{\circ}C$ for 0.5sec, it is seen that regraphitization is an inevitable phenomenon generated whatever processes used during multipass overlap remelting.

  • PDF

Dynamic Characteristics of Actuator for High Density Optical Recording Pick-up (고밀도 기록용 광픽업의 ACTUATOR 동특성)

  • 임경화;이용훈;김석중;이재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.258-263
    • /
    • 1995
  • 미래 정보와 시대에서 중추적인 역할을 할 광관련 멀티미디어 장비들은 최근 관련 산업계에서 주목을 받기 시작하고 있고 특히 기존 VTR(Video Tape Recorder) 시장을 대체할 차세대 DVDR(Digital Video Disk Recorder)는 기술전쟁이라고 할 정도로 선진 기업의 연구가 치열해지고 있다. DVDR 시스템에서는 필요한 정보들을 레이저빔을 이용한 광학신호로 바꾸어 광디스크에 기록, 재생하는 광픽업이 절대적으로 필요하게 된다. 그런데 광픽업의 위치추종기구인 Actuator는 정확한 위치추종(.+-.1.$\mu$m 오차이내)을 할 수 있는 성능이 요구되며 서보의 특성상 20KHz 이하에서 불필요한 모우드가 가진되지 않는 정밀부품이어야 하므로 Actuator 각 부품의 동적인 특성을 명확히 규명할 필요가 있다. 따라서 본 연구에서는 우선 Actuator 각 부품과 가동부 전체의 중량 및 진동해석을 통해 동특성을 조사하였다. 그리고 Actuator의 중요한 기본성능중 하나인 구동감도 확보여부를 검토할 필요가 있기 때문에 유한요소법 프로그램인 ANSYS를 이용하여 자기회로 부분에 대한 해석을 구하였다. 또한 가동부와 자기회로 등 하위부품을 조립하는 과정에서 발생하는 조립오차로 인해 불필요한 공진과 회전형상이 야기될 수 있으므로 동특성 및 문제점 파악을 위한 민감도 분석이 필요하다. 따라서 본 연구에서는 가동부의 관성 모멘트 값과 강체에 대한 일반식을 이용한 자체 프로그램을 작성하여 조립공차를 구하였다. 이와같은 과정을 통해 구해진 설계값을 바탕으로 실제 제작된 Actuator에 대해서는 비접촉식 측정방법을 통해 동특성값을 측정하였고 이를 해석값과 상호 비교하였다.동강성행렬법(dynamic stiffness matrix method)을 이용하여 해석하고자 한다. 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.ive structures utilized in Client/server architecture for distribution and cooperative processing of application between server and client this study presents two different data management methods under the Client/server environment; one is "Remote Data Management Method" which uses file server or database server and. the other is "Distributed Data Management Method" using distributed database management system. The result of this study leads to the conclusion that in the client/server environment although distributed application is assumed, the data could become centralized (in the case of file server or database server) or decentralized (in the case of distributed

  • PDF

Development of 3D Printing System for Human Bone Model Manufacturing Using Medical Images (의료 영상을 이용한 인체 골 모형 제작의 3차원 프린팅 시스템 개발)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.433-441
    • /
    • 2017
  • The 3D printing selective laser sintering (SLS) and stereo lithography apparatus (SLA) method used for bone model production has good precision and resolution, but the printers are expensive and need professional knowledge for operation. The program that converts computed tomography digital imaging and communications in medicine (DICOM) file into STL (stereolithography) file is also expensive so requesting 3D printing companies takes a lot of time and cost, which is why they are not generally utilized in surgery. To produce bone models of fractured patients, the use of 3D imaging conversion program and 3D printing system should be convenient, and the cost of device and operation should be low. Besides, they should be able to produce big size bone models for application to surgery. Therefore, by using an fused deposition modeling (FDM) method 3D printer that uses thermoplastic materials such as DICOM Viewer OsiriX and plastic wires, this study developed 3D printing system for Fracture surgery Patients customized bone model production for many clinics to use for surgery of fracture patients by universalizing with no limit in printing sizes and low maintenance and production cost. It is expected to be widely applied to the overall areas of orthopedics' education, research and clinic. It is also expected to be conveniently used in not only university hospitals but also regular general hospitals.

Effect of Tinnitus after Bleeding, Acupuncture, Moxa, and Laser treatment (부황, 뜸, 침 레이저요법 시술이 耳鳴에 미치는 영향)

  • Park, Gyung-hwa;Han, Young-mok;Ahn, Soo-Hyun;Hwang, Chung-yeon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.1
    • /
    • pp.396-407
    • /
    • 1999
  • Although tinnitus is a common disease, it's reason, pathogenesis and treatment are not examined clearly. As tinnitus is a subjective complaint, it is not easy to evaluate objectively and to compare with another. In this study, we intend to estimate the effect of a variety of oriental medical treatments to tinnitus. We inquired about 30cases of tinnitus patients visited the Kwang-ju Oriental Medical Hospital of Wonkwang University from Apr. 1998 to Sep. 1998. We examined the 30cases in the view of sex, age, occupation, duration, etiologic factors, past history, associating symptoms, quality of tinnitus, and recovery rate after treatments. The results were as follows: 1. In distribution of sex, the ratio of male was $63.3\%$(19cases)and\;female\;was\;36.6\%$(11cases). 2. In distribution of age, the ratio of the 2th decade was $6.6\%(2cases),\;the\;3th\;decade\;was\;20.0\%(6cases),\;the\;4th\;decade\;was\;16.6\%(5cases),\;the\;5th\;decade\;was\;23.3\%(7cases),\;the\;6th\;decade\;was\;30.0\%\;(9cases),and\;the\;7th\;decade\;was\;3.3\%(1case)$. 3. In distribution of occupation, the ratio of employee was $23.3\%$(7cases), house-keeper was $63.3\%(11cases),\;farmer\;was\;16.6\%(5cases),\;teacher\;was\;13.3\%$ (4cases), and student, merchant, soldier was each $3.3\%$(1case). 4. In distribution of duration, the ratio of under 1month was $6.6\%$ (2cases), 1 month -6 months was $20.0\%$(6cases), 6 months- 12months was $30.0\%$(9cases), 12months-36months was $23.3\%$(7cases), and over 36months was $20.0\%$(6cases). 5. In etiologic factor of tinnitus, the ratio of unknown reason was $40.0\%$ (12cases), overwork was $16.6\%$(5cases), emotional stress was $10.0\%$(3cases), noise was $6.6\%$(2cases), cases of laying overwork upon stress was $13.3\%$(4cases), head trauma was $3.3\%$(1case), gun report was $3.3\%$ (1case), and after sickness was $6.6\%$(2cases). 6. 9 cases had experienced such a disease as meniere's disease, tympanitis, labyrinthitis, trauma of tympanum, hypertension, etc. 7. Commonly associated symptoms were dizziness, deafness, uneasiness, headache, ear fullness, fatigue, insomnia, nausea, vomiting, and forgetfulness. 8. Most frequent quality of tinnitus were buzzing, whistling, humming etc. 9. In $76.6\%$(23cases) of tinnitus patients, it was improved, but in $23.3%$(7cases) of them, not improved. Total recovery rate was $42.2\%$.

  • PDF