• Title/Summary/Keyword: 레이저빔 조사

Search Result 139, Processing Time 0.024 seconds

A Study of the Characteristics of Highly Spatially Resolved CW-laser-based Aerosol Lidar (고공간분해능 연속 광원을 이용한 미세먼지 라이다의 신호 특성에 관한 연구)

  • Sim, Juhyeon;Kim, Taekeong;Ju, Sohee;Noh, Youngmin;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • In this study we introduce a new method for high-spatial-resolution continuous wave (CW) aerosol lidar that has a high spatial resolution in the near field and a low spatial resolution at long distances. A normal lidar system uses a nanosecond-pulse laser and measures the round-trip TOF between the aerosol and laser to obtain range resolution. In this study, however, we propose a new type of spatially resolving aerosol lidar that uses laser-scattering images. Using a laser-light-scattering image, we have calculated the distance of each scattering aerosol image for a given pixel, and recovered the short-range aerosol extinction. For this purpose, we have calculated the distance image and the contribution range of the aerosol to the given one-pixel image, and finally we have calculated the extinction coefficients of the aerosol with range-resolved information. In the case of traditional aerosol lidar, we can only obtain the aerosol extinction coefficients above 400 m. Using our suggested method, it was possible to extend the range of the extinction coefficient lower then several tens of meters. Finally, we can remove the unknown short-range region of pulsed aerosol lidar using our method.

Hypofractionated Radiation Therapy for Early Glottic Cancer - Preliminary Results - (초기 성문암 환자에서의 소분할 조사법을 이용한 방사선치료 - 예비적 결과 -)

  • Wu Hong-Gyun;Hong Semie;Shin Seong Soo;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.301-305
    • /
    • 2001
  • Purpose : This study was peformed for the evaluation of the feasibility and toxicity of hypofractionated radiation therapy for early glottic cancer Methods and Materials : From February 1999 to February 2000, 20 patients with Histologically confirmed Stage I, II glottic cancer were enrolled into this study. There were 18 males and 2 females, the median age of the patients was 59 years. The distribution of stage distribution was as fellows; T1aN0-16 patients, T1bN0-1 patient, T2N0-3 patients. Eighteen patients underwent laryngomicroscopic biopsy only, and two patients underwent laser cordectomy. All patients received radical radiation therapy (2.5 Gy per fraction, 24 fractions, total 60 Gy). Median duration of treatment was 36 days (range $31\~45\;days$). Results : Radiation therapy were well tolerated. Most common acute reactions were odynophagia and hoarseness, and these reactions resolved after radiation therapy. There were one case of RTOG grade 3 odynophagia $(5\%)$, six cases of grade 3 hoarseness $(30\%)$. Response of radiation therapy was evaluated one month after completion of treatment. All patients revealed complete response. During follow up, total three cases of treatment failure were detected. two cases were local recurrence in 10 and 13 months of radiation therapy and one case was local recurrence and distant metastasis in 2 months of radiation therapy. Conclusion : This hypofractionated radiation therapy schedule was feasible and effective for control of early glottic cancer But longer follow up time would be required to assess the long-term disease control and the late complication by shortening radiation therapy duration.

  • PDF

A Study for The X-ray Image Acquisition Experiment Using by Gas Electron Multipliers (기체전자증폭기를 이용한 X-선 영상획득실험에 관한 연구)

  • 강상묵;한상효;조효성;남상희
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.83-89
    • /
    • 2003
  • The gas electron multiplier placed in the drift volume of conventional gas detectors, is a conceptually simple device for producing a large gas gain by concentrating the drift electric field over a very short distance to the point that electron avalanching occurs(〉 10$^4$ V/cm), greatly increasing the number of drifting electrons. This device consists of a thin insulating foil of several tens of urn in thickness. covered on each side with a thin metal layer(Cu), with tiny holes, usually 100 ${\mu}{\textrm}{m}$ or less in diameter. and with a spacing of 100-200 ${\mu}{\textrm}{m}$ through the entire foil. perforated by using chemical etching or high-powered laser beam technique In this study, we have investigated its operating properties with various experimental conditions, and demonstrated the possibility of using this device as a digital X-ray imaging sensor, by acquiring X-ray images based on the scintillation properties of the gas electron multiplier with standard CCD camera.

Characteristics of the Nd:YAG laser with stimulated brillouin scattering phase conjugate mirror (유도 브릴루앙 산란 위상공액 거울을 이용한 Nd:YAG 레이저 발진기의 출력특성)

  • 이동원;이성구;박승현;공홍진
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.548-553
    • /
    • 2002
  • We have investigated the output characteristics of a Nd:YAG oscillator with a Stimulated Brillouin Scattering phase conjugation mirror (SBS-PCM). FC-75 is used as an SBS gain medium and Cr:YAG (T=50%) as a Q-switcher. The SBS-PCM consists of an SBS-cell and a simple plano-convex focusing lens system. For the case of not using a Q-switcher, an SBS-cell doesn't work as a phase conjugation mirror. For the case of using a Q-switcher, the energy characteristics remains nearly the same whether using the SBS-cell or not using it. The pulse width is reduced from 50 ns to 40 ns by an SBS-PCM. When the SBS-cell is used with a Q- switcher, the SBS-cell works very well as a phase conjugation mirror and its beam-profile is improved dramatically. And in order to explain the progression of beam-profile, we propose a simple model based on the nonlinear reflectivity of the SBS-PCM, whose reflectivity is dependent on the pumping intensity at the focal plane.

A study on the fabrication of heatable glass using conductive metal thin film on Low-e glass (로이유리의 전도성 금속박막을 이용한 발열유리 제작에 관한 연구)

  • Oh, Chaegon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.105-112
    • /
    • 2018
  • This paper proposes a method for fabricating heatable glass using the conduction characteristics of metal thin films deposited on the surface of Low-e(Low emissivity) glass. The heating value of Low-e glass depends on the Joule heat caused by Low-e glass sheet resistance. Hence, its prediction and design are possible by measuring the sheet resistance of the material. In this study, silver electrodes were placed at 50 mm intervals on a soft Low-e glass sample with a low emissivity layer of 11 nm. This study measured the sheet resistance using a 4-point probe, predicted the power consumption and heating value of the Low-e glass, and confirmed the heating performance through fabrication and experience. There are two conventional methods for manufacturing heatable glass. One is a method of inserting nichrome heating wire into normal glass, and the other is a method of depositing a conductive transparent thin film on normal glass. The method of inserting nichrome heating wire is excellent in terms of the heating performance, but it damages the transparency of the glass. The method for depositing a conductive transparent thin film is good in terms of transparency, but its practicality is low because of its complicated process. This paper proposes a method for manufacturing heatable glass with the desired heating performance using Low-e glass, which is used mainly to improve the insulation performance of a building. That is by emitting a laser beam to the conductive metal film coated on the entire surface of the Low-e glass. The proposed method is superior in terms of transparency to the conventional method of inserting nichrome heating wire, and the manufacturing process is simpler than the method of depositing a conductive transparent thin film. In addition, the heat characteristics were compared according to the patterning of the surface thin film of the Low-e glass by an emitting laser and the laser output conditions suitable for Low-e glass.

New Analysis Approach to the Characteristics of Excimer Laser Annealed Polycrystalline Si Thin Film by use of the Angle wrapping (엑시며 레이저에 의해 형성된 다결정 실리콘 박막의 Angle wrapping에 의한 깊이에 따른 특성변화)

  • Lee, Chang-U;Go, Seok-Jung
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.884-889
    • /
    • 1998
  • Amorphous silicon films of large area have been crystallized by a line shape excimer laser beam of one dimensional scanning with a gaussian profile in the scanning direction. In order to characterize the crystalline phase transition of thickness variables in excimer laser annealing(ELA), angle wrapping method was used. And also to characterize the residual stresses of crystalline phase transition in the case of angle wrapped-crystalline silicon on corning 7059 glass, polarized raman spectroscopies were measured at various laser energy density and substrate temperature. The residual stress varies from $9.0{\times}10^9$ to $9.9{\times}10^9$, and from $9.9{\times}10^9$ to $1.2{\times}10^10$dyne/${cm}^2$ of the substrate temperature at room temperature and varies from $8.1{\times}10^9$ to $9.0{\times}10^9$, and from $9.0{\times}10^9$ to $9.9{\times}10^9$dyne/${cm}^2$ of the substrate temperature at $400^{\circ}C$ as a function of direction from surface to substrate. According to the direction from the surface in liquid phase to the interface and from the interface to near the substrate in solid phase of recrystallized Si thin film, respectively. Thus, the stress is increased from(Liquid phase to solid phase) with phase transition.

  • PDF

The Electrical Characteristics of Low-Temperature Poly-Si Thin-Film Transistors by Different Crystallization Methods

  • Kim, Mun-Su;Jang, Gyeong-Su;Lee, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.287.1-287.1
    • /
    • 2014
  • 본 연구에서는 현재 디스플레이에서 가장 널리 이용되는 저온 polycrystalline silicon (poly-Si)의 결정화 방법에 따른 thin-film transistor (TFT)의 전기적 특성을 분석하였다. 분석에 이용된 결정화 방식은 Excimer Laser Annealing (ELA)와 Metal Induced Crystallization (MIC)이다. ELA와 MIC TFTs의 전기적 특성 측정을 통한 분석결과 ELA와 MIC poly-Si TFTs의 전기적 특성 [field-effect mobility (${\mu}_{FE}$), on/off current ratio ($I_{ON}/I_{OFF}$), sub-threshold swing (SS)]은 큰 차이는 없지만, ELA를 이용한 poly-Si TFT의 전기적 특성이 조금 우수하다. 하지만, MIC poly-Si TFT의 경우 threshold voltage ($V_{TH}$)가 0V에 보다 가까울 뿐만 아니라, 전기적 스트레스를 통한 신뢰성 확인 시 ELA poly-Si TFT보다 조금 더 안정적이다. 이는 ELA의 경우 좁은 면에 선형 레이저 빔으로 조사하면서 생기는 hill-lock의 영향으로 표면이 거칠고 균일하지 못하여 바이어스 인가시 생기는 문제이다. 또한 MIC는 금속 촉매를 이용해 결정립 경계를 확장하고 결정 크기를 키워 대면적화에 유리하다. Thermal Stress에서는 (from 293K to 373K) TFT에 점차 높은 온도를 가하자 MIC poly-Si TFT의 경우 off 상태에서 누설 전류 값이 증가하며 열에 민감한 반응을 보이는 것을 확인하였다.

  • PDF

경사입사각증착법을 이용한 이산화 티타늄 박막 기반의 고반사 분포 브래그 반사기 제작 및 특성

  • Guan, Xiang-Yu;Im, Jeong-U;Jeong, Gwan-Su;Yu, Jae-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.350.1-350.1
    • /
    • 2014
  • 분포 브래그 반사기(distributed Bragg reflector; DBR)는 광센서, 도파로, 태양전지, 반도체 레이저 다이오드, 광검출기와 같은 고성능 광 및 광전소자 응용분야에 널리 사용되고 있다. 일반적으로, DBR은 박막의 두께를 4분의 1 파장(${\lambda}/4$)으로 가지는 서로 다른 저굴절율 물질과 고굴절율 물질을 교대로 적층 (pair)한 다중 pair로 제작되어지며, DBR의 반사 특성과 반사대역폭은 두 물질의 굴절율 차이와 pair의 수에 영향을 받는다. 그러나, 서로 다른 굴절율을 갖는 두 물질을 이용하는 DBR의 경우, 두 물질간 열팽창계수의 불일치, 접착력 문제, 높은 굴절율 차이를 갖는 물질 선택의 어려움 등 많은 문제점을 지니고 있다. 최근, 경사입사각증착법을 이용한 동일 재료(예, 인듐 주석 산화물, 게르마늄, 실리콘)기반의 DBR 제작 및 특성에 대한 연구가 보고되고 있다. 높은 입사각을 갖고 박막이 증착될 경우, 저율을 갖는 다공박막 제작이 가능하여 경사입사각증착법으로 homogeneous 물질 기반의 고반사 특성을 갖는 다중 pair의 DBR을 제작할 수 있다. 본 실험은, 갈륨비소 기판 위에 경사입사각증착법 및 전자빔증착법을 이용하여 중심파장 960 nm가 되는 이산화 티타늄 기반의 DBR을 제작하였고, 제작된 샘플의 증착된 박막의 표면 및 단면의 프로파일은 주사전자현미경을 사용하여 관찰하였으며, UV-Vis-NIR 스펙트로미터를 이용하여 반사율 특성을 조사하였다.

  • PDF

The study on temperature distribution characteristic of irradiated surface by CO2 laser (온도센서를 이용한 CO2레이저 빔 조사면의 온도 분포 특성에 관한 연구)

  • Min, Byoung-Dae;Kim, Tae-Kyun;Chung, Hyun-Ju;Kim, Yong-Cheol;Joung, Jong-Han;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1831-1833
    • /
    • 2003
  • Nowadays, CO2 lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, CO2 lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam quality in those fields. To increase beam qualify, We used the feedback system by various sensors. Although, CO2 lasers' output beam became feedback, its beam affected the irradiated material target already. Since, ideal real time control have still the problem to solve. Hence, we need the new proposal for more precise laser processing. So we expect the new effect how to change the irradiated material target as the kind of, processing time and output density caused by the CO2 laser beam. In this study, We have investigated the characteristics of the temperature and HAZ(Heat Affected Zone) by CO2 laser output with IR temperature sensor and RTD.

  • PDF

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF