• Title/Summary/Keyword: 디지털 치과학

Search Result 206, Processing Time 0.021 seconds

Web viewer for sharing of prosthesis design between laboratory and clinic: Case report (웹뷰어를 이용한 기공실과 진료실 측 간의 보철물 설계 형태의 공유: 증례 보고)

  • Jang, Sung Won;Lee, Ho Jin;Kim, So-Yeun;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.276-282
    • /
    • 2022
  • Close communication between clinicians and dental technicians is an important factor in providing successful prostheses. The exchange of opinions with laboratories has mainly been in the form of written prescriptions and a photos, but it has been reported that information transmission may be limited. Currently, as digital technology-based prosthesis fabrication is common, 3D image objects can be stored on the web and can be easily viewed through a mobile web browser. In this article, we introduce cases where the design of the prosthesis was improved by designing the prosthesis using CAD software and reviewing the prosthesis designed with the clinical side through a web viewer. Through this protocol, it was possible to improve the occlusal surface and crown contour, the opposing teeth condition, the size of the gingival embrasure, and the shape of pontic. The process of sharing, discussing, and modifying the prosthesis design with the clinician and technician through a web viewer contributes to reflecting the diversity of oral conditions and individualized needs, thereby helping to make functional and esthetic prostheses.

The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report (편측 소수 잔존치 증례에서 CAD software를 활용한 planning 및 임플란트 서베이드 고정성 보철물을 이용한 국소의치 수복: 증례보고)

  • Park, Jeongkeun;Kim, Jong-Eun;Park, Ji-Man;Kim, Jeehwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.254-262
    • /
    • 2019
  • As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.

A comparative study of impression methods using stock tray and intraoral scanner in a completely edentulous patient with an atypical arch shape: a case report (비정형적인 악궁을 가진 완전 무치악 환자에서 기성 트레이와 구강 스캐너를 이용한 인상 채득 방법의 비교 연구: 증례 보고)

  • Jae-Hoon Park;Ji-Hyun Kim;Jae-Min Seo;Jung-Jin Lee;Yeon-Hee Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.344-355
    • /
    • 2023
  • In complete denture fabrication, accurate preliminary impressions are crucial for obtaining an accurate final impression. However, it can be challenging in cases of atypical arch shapes. This case report compares diagnostic casts made with a stock tray and an intraoral scanner (IOS) in a patient with an atypical arch shape. A 58-year-old edentulous male patient with long, narrow, atypical arches was referred to the Oral and Maxillofacial Surgery department for complete denture fabrication. Compared to the diagnostic cast obtained using IOS with adequately captured anatomical parameters, the primary model obtained using a stock tray showed prominent overextended flanges on the labial and buccal sides of the maxillary arch and less prominent overextended flanges in the mandibular arch with pressure spots in the posterior palatal seal area. The custom tray fabricated from such a model required additional adjustment resulting in increased chair time during the final impression procedure.

RPD framework fabrication using computer-aided design (CAD) and rapid prototyping (Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례)

  • Park, Seon-Ah;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.94-99
    • /
    • 2017
  • Nowadays, digital dentistry is generally applied to prosthodontics with fabrication of inlays or any other fixed prostheses by utilizing CAD/CAM (computer-aided design/computer-aided manufacturing) technology and intraoral scanner. However, in fabricating removable prosthesis, there are some limitations for digital technology to substitute conventional casting method. Therefore, approaching removable prostheses fabrication with CAD/CAM technology would be a meaningful trial. In this case report, Kennedy class III mandibular edentulous patient who was in need of increasing the vertical dimension of occlusion was treated with removable partial denture using CAD and rapid prototyping technique. Surveying and designing the metal framework of the partial denture was performed with CAD, and sacrificial plastic pattern was fabricated with rapid prototyping technique. During the follow up period of nine months, the removable partial denture has provided satisfactory results in esthetics and function.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

Fabrication of functionally customized fixed prosthesis in a hemimandibulectomy patient with fibular graft using double scan technique: A case report (비골이식을 받은 하악골절제술 환자에서 스캔중첩법을 이용한 기능적 고정성 보철물 제작: 증례 보고)

  • Win, Thaw Thaw;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.195-201
    • /
    • 2022
  • Hemimandibulectomy and free fibular flap (FFF) in patients with squamous cell carcinoma could disturb the functional movement of the mandible. The muscular function in the sectioned side was compromised because of the incompetency of the muscle attachment to the mandible, leading to the unstable occlusal contact in the centric and eccentric occlusion. In this report, we present a case of a 63-year-old male who underwent cancer surgery and reconstruction with fibular graft, and he needed a fixed dental prosthesis to restore tooth loss in the anterior region. Occlusal contact change and instability were found according to the bite force in the centric relation and eccentric movement. This case report aimed to present the prosthetic procedure for fabricating the functionally optimized fixed prosthesis wherein the functionally generated path (FGP) technique and digital imaging method were applied to replicate mandibular movement and vertical dimension of the patient.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Functional and esthetic improvement through reconstruction of anterior guidance using the modified Dahl principle and copy-milled technique of CAD/CAM system: A case report (적절한 전방 유도 재현을 위해 수정된 Dahl 원리 및 CAD/CAM 복제 기법을 이용하여 전치부의 기능 및 심미성을 개선한 보철 수복 증례)

  • Kim, Sung-Ho;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.160-170
    • /
    • 2019
  • The anterior guidance is one of the important factors in prosthodontic treatment of anterior teeth. The lingual surface shape of anterior restorations is so critical that small errors of treatment procedure can cause discomfort of the patient and disharmony of the dentition. If the anterior restorations are achieved harmonious anterior guidance through the fabrication and adjustment of provisional restorations, it is important to accurately reproduce the lingual surface shape of provisional restorations as the final prosthesis. In this case report, it was used the modified Dahl principle and copy-milled technique of computer-aided design/computer-aided manufacturing (CAD/CAM) system for systematic diagnosis and treatment. Therefore, we tried to reconstruct the restoration shape more precisely by setting the appropriate anterior guidance and superimposing the digital image of the abutment teeth and the provisional restorations. Thus, by promoting functional and esthetic recovery, this case report demonstrates satisfying results to both the patients and dentist.

Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review (국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰)

  • Yi, Yuseung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.370-378
    • /
    • 2021
  • Purpose. The purpose of this study was to evaluate the currently published literatures investigating the accuracy of computer-aided design and computer-aided manufacturing removable partial denture (CAD-CAM RPD) framework with different manufacturing techniques and methods. Materials and methods. A comprehensive search for literatures was conducted in PubMed database using specific keywords with the patient, intervention, comparison, and outcome (PICO) question, "Is there a difference in accuracy of RPD frameworks manufactured using digital workflow according to the manufacturing process and methods?" Results. A total of 7 articles were selected. Two studies compared intraoral scanning and laboratory scanning for RPD frameworks and had heterogenous results. In the studies using different manufacturing process, RPD frameworks had clinically acceptable accuracy in both subtractive and additive manufacturing. Polyetheretherketone (PEEK)-milled RPD frameworks showed higher fit accuracy than traditionally casted or 3D printed RPDs. Direct milling method showed a higher accuracy than indirect milling method. However, in rapid prototyping, indirect method showed higher accuracy than direct method. Conclusion. The RPD frameworks fabricated using CAD-CAM technology showed a clinically acceptable level of accuracy regardless of manufacturing process or techniques. Consistent results have not been reported regarding the digital impression methods, which were intra oral scanning or laboratory scanning, and further studies are needed.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.