• Title/Summary/Keyword: 디지털 국소의치

Search Result 23, Processing Time 0.026 seconds

Restoration of partial removable dental prosthesis after fabricating of surveyed crowns utilizing electronic surveying: a case report (전자 서베잉을 이용한 서베이드 크라운 제작 후 국소의치 수복: 증례보고)

  • Min, Byungkwee;Jun, Daejeon;Yang, Hongso;Park, Sangwon;Lim, Hyunpil;Yun, Kwidug;Park, Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.135-142
    • /
    • 2017
  • Adoption of CAD/CAM milling in dentistry has allowed production of more analytic and precise prosthesis. Such precision enables definite path of insertion and undercut to be provided in removable partial denture especially when designing a surveyed crown on an abutment tooth. This case is about the production of surveyed crown with proper path of insertion utilizing CAD/CAM electronic surveying method on a patient with edentulous maxilla. Resulting removable partial denture fit well and showed acceptable stability and retention with no clinical problem.

The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report (편측 소수 잔존치 증례에서 CAD software를 활용한 planning 및 임플란트 서베이드 고정성 보철물을 이용한 국소의치 수복: 증례보고)

  • Park, Jeongkeun;Kim, Jong-Eun;Park, Ji-Man;Kim, Jeehwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.254-262
    • /
    • 2019
  • As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Comparison of internal adaptation of removable partial denture metal frameworks made by lost wax technique and printing technique of pattern using CAD (Lost wax technique과 CAD를 이용한 pattern의 프린팅 방식으로 제작된 가철성 국소의치 금속구조물의 적합도 비교)

  • Choi, Wonjun;Woo, Yi-Hyung;Kim, Hyeong-Seob;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Lost wax technique of casting wax patterns has been used principally to make metal frameworks of removable partial dentures. Since the development of digital technology and CAD, metal frameworks can be built through digital surveying and framework designing. Many cases proved that resin patterns made by CAD printing method were well adapted to internal oral structure and final metal frameworks also showed good internal adaptation as well. The metal frameworks of a removable partial denture were made by both lost wax technique and CAD technique and were applied to a patient with severe alveolar bone loss. Using CAD data and fit checker, internal adaptation of both metal frameworks were evaluated by comparing the gap between surveyed crown and its structure. This study is to prove that metal frameworks by both techniques showed adaptation that can be applied in clinical field.

Utilization of digital technology in fabricating mandibular implant overdenture for skeletal class II edentulous patient: A case report (2급 악간관계를 보이는 하악 무치악 환자에서 디지털 진단기술을 이용한 임플란트 피개의치 수복증례)

  • Lee, Yeun-Yi;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.364-373
    • /
    • 2019
  • Unlike class I patients, skeletal class II patients have unstable occlusion thus leading to instability of mandibular complete denture. Therefore, mandibular implant overdenture has been the standard of care due to its advantages in stability and retention. The types of attachments can be divided into two categories: solitary and bar type. The indications vary between two categories. In this clinical report, digital technology was utilized from the implant planning to the choice of appropriate attachment. Implants were placed at the desired location as previously planned in terms of angle and depth. Maxillary removable partial denture and mandibular implant overdenture are expected to have fair prognosis.

Use of digital scan data for evaluation of edentulous ridge relationship: A case report for removable prosthesis with unilateral cross bite (디지털 스캔 데이터를 활용한 무치악 치조제 관계의 평가와 인공치 선택: 편측 교차교합의 가철성 의치 수복 증례)

  • Kim, Jeong-Hoon;Kim, Jong-Eun;Park, Young-Bum;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.304-311
    • /
    • 2019
  • After the teeth were extracted, maxillary and mandibular alveolar ridges show the opposite resorption pattern and as a result, the mandibular arch is enlarged than maxillary arch relatively. In this situation, we should evaluate both alveolar ridge relationship and arrange the artificial teeth properly for stability of removable prosthesis. This case is a 77 years old male patient who wishes to make removable prosthesis and has atrophic alveolar ridge. By use of model scanner and CAD software, the angle between interalveolar crest line and occlusal plane was easily measured. Depending on the measurement, the artificial teeth are arranged in unilateral cross bite and after completion, patient was satisfied with the denture which showed proper stability, retention, support.

Accuracy of CAD-CAM RPD framework according to manufacturing method: A literature review (국소의치 구조물(framework)의 CAD-CAM 제조방식에 따른 정확도: 문헌고찰)

  • Yi, Yuseung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.370-378
    • /
    • 2021
  • Purpose. The purpose of this study was to evaluate the currently published literatures investigating the accuracy of computer-aided design and computer-aided manufacturing removable partial denture (CAD-CAM RPD) framework with different manufacturing techniques and methods. Materials and methods. A comprehensive search for literatures was conducted in PubMed database using specific keywords with the patient, intervention, comparison, and outcome (PICO) question, "Is there a difference in accuracy of RPD frameworks manufactured using digital workflow according to the manufacturing process and methods?" Results. A total of 7 articles were selected. Two studies compared intraoral scanning and laboratory scanning for RPD frameworks and had heterogenous results. In the studies using different manufacturing process, RPD frameworks had clinically acceptable accuracy in both subtractive and additive manufacturing. Polyetheretherketone (PEEK)-milled RPD frameworks showed higher fit accuracy than traditionally casted or 3D printed RPDs. Direct milling method showed a higher accuracy than indirect milling method. However, in rapid prototyping, indirect method showed higher accuracy than direct method. Conclusion. The RPD frameworks fabricated using CAD-CAM technology showed a clinically acceptable level of accuracy regardless of manufacturing process or techniques. Consistent results have not been reported regarding the digital impression methods, which were intra oral scanning or laboratory scanning, and further studies are needed.

Partial Denture Prosthesis Implant and Necessity Thereof in Korean Elderly : Analysis of the Data from the 5th National Health Nutrition Survey(2010-2012) (한국노인의 가공의치 보철장착실태 및 필요도: 제5기 국민건강영양조사자료 분석(2010-2012))

  • Yun, Hyun-Kyung;Lee, Jong-Hwa;Lee, Seung-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.6
    • /
    • pp.467-479
    • /
    • 2014
  • The purpose of this study was to provide the data for discussion related to oral health promotion policies for the elderly by examining and analyzing the prosthesis conditions and necessity for the fixed and removable dentures among the Korean elderly. The data, obtained from 4,557 elderly aged at 65 or higher who were targeted for the 5th National Health Nutrition Survey, were analyzed through the complex sample frequency analysis, complex sample cross analysis, and complex sample logistic regression analysis. The results of analysis showed significant relevance of whole denture implant and the necessity thereof in older subjects, rural community, and subjects with lower education background, regarding the state of upper jaw/lower jaw prosthesis and the necessity for upper jaw/lower jaw fixed partial denture/whole denture. In addition, the necessity for prosthesis implant was found to have correlation with the income and subjective health condition, while the necessity for artificial teeth(denture) was found to have correlation with the gender, age, education, and subjective oral health condition. Therefore, it is considered necessary to map out the prevention and treatment policies designed to help maintain and promote oral health based on oral health education, along with the policies that aim to recover the neutralized oral health functions, in relation to the oral health of the elderly.

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.