• Title/Summary/Keyword: 디지털치료

Search Result 672, Processing Time 0.025 seconds

Comparative Study on the Ability of Instruments to Maintain Original Canal Curvature of Continuous rotary System and Single File System (Continuous rotary system과 single file system의 만곡 근관 형태 유지능에 대한 비교 연구)

  • Park, Sang-Hee;Kim, Deok-Joong;Song, Yong-Beom;Lee, Hye-Yun;Kim, Hyoung-Sun;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.371-383
    • /
    • 2012
  • Shaping the root canal system to maintain original canal curvature is essential to clinical success in endodontic treatment. Opposed to most root canals that are curved, endodontic instruments are made from straight metal blanks. They have a tendency of straightening the root canal during preparation and frequently result in procedural errors. A new treatment method to maintain original canal curvature during shaping has been introduced for preventing procedural errors. The aim of this study was to compare the ability of instruments to maintain original canal curvature of continuous rotary system and single file system. Thirty ISO 15, 0.02 taper, Endo Training Blocks(Dentsplay Maillefer) were used. Specimens were assigned to 1 of 3 groups for shaping: specimens in group 1 were shaped with ProFile #20/.06 at the WL. Specimens in group 2 were shaped with Mtwo #35/.04 at the WL. Specimens in group 3 were shaped with WaveOne Primary reciprocating files at the WL after the glide path was achieved with PathFile. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b(The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio(CRr), representing canal curvature modification. Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file were analyzed with 1-way ANOVA(P<.05). Data for comparison on the ability of instruments to maintain original canal curvature depending on each Ni-Ti file system were analyzed with independent t-test(P<.05). A statistically significant difference(P<0.05) was noted on each Ni-Ti file. ProFile and WaveOne instrumentations maintained the original canal curvature significantly better(P<0.05) than Mtwo file. There were no significant difference(P>0.05) between continuous rotary system and single file system. Under the conditions of this study, ProFile and WaveOne instruments maintained the original curvature significantly better than Mtwo file and were less modification of the canal curvature compared. There was no significant difference between continuous rotary system and single file system in shaping of simulated canals. As clinical practitioners, it may be advantages to use hybrid approach when root canal shapes depending on the design and usage of Ni-Ti files.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

The Effects of Pet Dog-Assisted Activities on Self-Esteem, Depression and Cognitive Function among Elderly People (애완견 매개활동이 노인의 자기존중감, 우울 및 인지기능에 미치는 효과)

  • Shin, Esther;Lee, Sung-Kook
    • Journal of agricultural medicine and community health
    • /
    • v.35 no.3
    • /
    • pp.314-325
    • /
    • 2010
  • Objectives: The purpose of this study was to investigate the effects of pet dog-assisted activities on self-esteem, depression and cognitive function of elderly people Method: The experimental group(pet dog-assisted group) consisted of 22 people over 65 years old out of about 90 elderly people registered with a home for the aged and the control group(non-pet dog assisted group) consisted of 22 people over 65 years old out of about 90 elderly people registered with another home for the aged in Daegu. Both groups had similar general characteristics, state of health, conduct on health and self-esteem, depression and cognitive abilities. Nineteen people who participated in the program at least 10 times out of 12, were chosen for the final analysis from the experimental group. For the control group, 20 people who responded to all three tests, which had been conducted before, 1 week after, and four week after the experiment, were analyzed. Result: Mean(${\pm}SD$) differences between before and 1 week after the experiment for self-esteem, depression, and cognitive function were 5.84(${\pm}3.06$), -3.26(${\pm}1.76$), 1.47(${\pm}1.26$), respectively. Those between before the experiment and 4 weeks after the experiment was 5.68(${\pm}3.64$), -3.94(${\pm}2.32$), 1.63(${\pm}0.96$), respectively. Those for control group between before and after the experiment were -0.40(${\pm}1.27$), 0.00(${\pm}0.92$), 0.15(${\pm}0.93$), respectively. Those for control group between before and 4 weeks after the experiment were -0.45(${\pm}2.24$), 0.25(${\pm}1.68$), 0.15(${\pm}0.93$), respectively. All the differences between experiment and control group in mean differences between before and 1 week after experiment, between before and 4 weeks after experiment were statistically significant(p<0.05). Conclusion: This study suggests that the pet-assisted activities can be useful solution for elderly people who have psychological and emotional problems caused by retrogression of physical, mental and social ability.

Evaluation of Image Quality by Using a Tungsten Edge Block in a Megavoltage (MV) X-ray Imaging (텅스텐 엣지 블록을 이용하여 Megavoltage (MV) 영상의 질 평가)

  • Min, Jung-Whan;Son, Jin-Hyun;Kim, Ki-Won;Lee, Jung-Woo;Son, Soon-Yong;Back, Geum-Mun;Kim, Jung-Min;Kim, Yeon-Rae;Jung, Jae-Yong;Kim, Sang-Young;Lee, Do-Wan;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.154-161
    • /
    • 2012
  • Digital Radiography (DR) has rapidly developed in megavoltage X-ray imaging (MVI). Thus, a very simple and general quality assurance (QA) method is required. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) for MVI using general QA method and computed radiography (CR) device. We used tungsten edge block with $19{\times}10{\times}1cm^3$ thickness and 6MV energy. For detector, CR-IP (image plate), CR-IP-lead, the CR-IP-back (lanex TM fast back screen), CR-IP-front (lanex TM fast front screen) were used and pre-sampling MTF was calculated. The MTF of CR-IP-front showed the highest value with 1.10 lp/mm although the CR-IP showed the only 0.70 lp/mm. The best NPS was observed in CR-IP front screen. According to the increase in spatial frequency, our results showed that DQE was approximately 1.0 cycles/mm. The present study demonstrates that the QA method with our home-made edge block can be used to evaluate MTF, NPS and DQE for MVI.

Comparison of condylar guidance using ARCUSdigma 2 and Checkbite (ARCUSdigma 2와 Checkbite를 사용하여 측정한 과로경사각 비교)

  • Lee, Dong-In;Lee, Chang-Hee;Son, Mee-Kyoung;Chung, Chae-Heon;Kang, Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.153-159
    • /
    • 2013
  • Purpose: Nowadays, checkbite methods and a digital sensor are used to analyze the movement of mandible. However, there are no study comparing two methods. Therefore, this study has compared measuring the condylar inclination methods by using the new ARCUSdigma 2 system and the checkbite method. Materials and methods: Young 20 adults without any orthodontic treatment experiences, missing teeth, and restorations with the change of occlusal plane were tested. Angles of condylar path were measured 3 times each, based on Camper's line, by using two methods. KaVo PROTAR Evo 7 semi-adjustable articulator was used and the data were statistically analyzed. Results: 1. The anterior sagittal condylar inclination by ARCUSdigma 2 system were measured as $26.97^{\circ}({\pm}7.38^{\circ})$ on the left side and $29.80^{\circ}({\pm}8.19^{\circ})$ on the right side. The lateral condylar inclination were measured as $5.75^{\circ}({\pm}3.47^{\circ})$ on the left side and $8.10^{\circ}({\pm}4.98^{\circ})$ on the right side. 2. The anterior sagittal condylar inclination by checkbite method were measured as $25.20^{\circ}({\pm}6.53^{\circ})$ on the left side and $28.18^{\circ}({\pm}7.38^{\circ})$ on the right side. The lateral condylar inclination were measured as $10.97^{\circ}({\pm}5.63^{\circ})$ on the left side and $12.03^{\circ}({\pm}5.22^{\circ})$ on the right side. There was no statistically significant difference between male and female (P>.05). 3. The lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05). Conclusion: In Both of 2 methods, there was no statistically significant difference between male and female (P>.05). However, the lateral condylar inclinations of ARCUSdigma 2 were statistically significantly smaller than that of checkbite method (P<.05).

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging (3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안)

  • Chang, Hye-Sook;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.313-325
    • /
    • 2002
  • Three-dimensional CT imaging is efficient in examining specific structures in the craniofacial area by reproducing actual measurements through minimization of errors from patient movement and image magnification. Due to the rapid development of digital image technology and the expansion of treatment range a need for developing three -dimensional analysis has become urgent. Therefore the purpose of this study was to evaluate the percentage of error and magnification of three-dimensional CT using a dried skull and Vworks $program^{TM}$ (Cybermed Inc., Seoul, Korea) and also to obtain landmarks that are easy to designate and reproduce in three-dimensional images using the Vmorph-proto $program^{TM}$ (Cybermed Inc., Seoul, Korea). The following conclusions were obtained, 1. In the comparison of actual measurements from the dried skull and the three-dimensional image obtained from the Vworks program, the mean error was 0.99mm and the magnification was 1.04%. 2. Clinically useful hard tissue landmarks from three-dimensional images were Supraorbitale, Lateral orbital margin, Infraorbitale, Nasion, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch and Basion. 3. Clinically useful soft tissue landmarks from three-dimensional images were Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton and Preaurale. The Vworks program can be considered a clinically efficient tool to produce and measure three-dimensional images. Most of the hard and soft tissue landmarks proposed above are anatomically important points which are also easily reproducible and designated. These landmarks can be beneficial in three-dimensional diagnosis and the prediction of changes before and after surgery.

Socioeconomic Determinants of Suicide Rate in Korea (경제적 양극화와 자살의 상관성: 1997년 외환위기를 전후하여)

  • Eun, Ki-Soo
    • Korea journal of population studies
    • /
    • v.28 no.2
    • /
    • pp.97-129
    • /
    • 2005
  • Korean society recently witnesses a rapid lllcrease of suicide across all ages. In particular, suicide in old ages jumps up ill a very unexpected way. Furthermore, the order of suicide in the cause of death across all ages is becoming higher and higher in Korea. This study provides details of suicide that occurs in Korean society with the comparison to that of Japan at the descriptive level. It is not well known why suicide in Korean surges recently. Several previous research show the possibility that surging suicide is closely related to the worsened economic conditions especially since the economic crisis in 1997. They adopt economic growth, unemployment rate, income distribution, household finance index as economic indicators in their research. This study also adopts those indicators and conducts a correlation analysis in two periods, 1990-1997 and 1998-2004. It is found that there is no correlation between economic indicators and suicide in the period of 1990-1997. On the other hand, there is a very strong correlation between income distribution and suicide in the period of 1998-2004. Other economic indicators except income distribution does not have any significant correlation with suicide. This finding suggests that currently increasing suicide in Korea may be a result of economic polarization, which has been worsened since the economic crisis in 1997.

A historical study on the flexibility square-format typeface and the prospects - Focused on the three-pairs fonts of hangeul - (탈네모글꼴에 관한 역사적 연구와 전망 - 세벌식 한글 글꼴을 중심으로 -)

  • Yu, Jeong-Mi
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.241-250
    • /
    • 2006
  • Hangeul as the Korean unique characters were invented according to some character-making principles and based on scholars' exhaustive researches. While most of the characters in the world evolved naturally, Hangeul was invented based on a precise linguistic analysis of the time, and therefore, it is most scientific and reasonable among various characters throughout the world. Nevertheless, Hangeul typeface designs do not seem to inherit the ideology of scientific and reasonable Hangeul correctly. For the square forms have been used intact due to the influences from the Chinese characters which prevailed during the time. If a single set of square characters should be designed, as much as 11,172 fonts should be designed, which suggests that advantages of Mangeul may not well be used fully; Hangeul was invented to visualize every sound with the combinations of 28 vowels and consonants. Problems of such square fonts began to be identified since 1900's when typewriters were introduced first from the West. Since a typewriter is designed with 28 characters laid out on its keyboard by using such combinations, the letters may be easily combined on it. The so-called the flexibility square-format typeface was born as such. Specially, the three-pairs fonts of these can be combined up to 67 letters including vowels and consonants. The three-pairs fonts system can help to solve the problems arising form the conventional square fonts and inherit the original ideology of Hangeul invention. This study aims to review the history of the three-pairs fonts designs facilitated by mechanic encoding of Hangeul and thereupon, suggest some desirable directions for future Hangeul fonts. Since the flexibility square-format typeface is expected to evolve more and more owing to development of the digital technology, they would serve our age of information in terms of both functions and convenience. Just as Hunminjongum tried to be literally independent from the Chinese characters, so the flexibility square-format typeface designs would serve to recover identity of our Hangeul font designs.

  • PDF

A Study on Human-Robot Interaction Trends Using BERTopic (BERTopic을 활용한 인간-로봇 상호작용 동향 연구)

  • Jeonghun Kim;Kee-Young Kwahk
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.3
    • /
    • pp.185-209
    • /
    • 2023
  • With the advent of the 4th industrial revolution, various technologies have received much attention. Technologies related to the 4th industry include the Internet of Things (IoT), big data, artificial intelligence, virtual reality (VR), 3D printers, and robotics, and these technologies are often converged. In particular, the robotics field is combined with technologies such as big data, artificial intelligence, VR, and digital twins. Accordingly, much research using robotics is being conducted, which is applied to distribution, airports, hotels, restaurants, and transportation fields. In the given situation, research on human-robot interaction is attracting attention, but it has not yet reached the level of user satisfaction. However, research on robots capable of perfect communication is steadily being conducted, and it is expected that it will be able to replace human emotional labor. Therefore, it is necessary to discuss whether the current human-robot interaction technology can be applied to business. To this end, this study first examines the trend of human-robot interaction technology. Second, we compare LDA (Latent Dirichlet Allocation) topic modeling and BERTopic topic modeling methods. As a result, we found that the concept of human-robot interaction and basic interaction was discussed in the studies from 1992 to 2002. From 2003 to 2012, many studies on social expression were conducted, and studies related to judgment such as face detection and recognition were conducted. In the studies from 2013 to 2022, service topics such as elderly nursing, education, and autism treatment appeared, and research on social expression continued. However, it seems that it has not yet reached the level that can be applied to business. As a result of comparing LDA (Latent Dirichlet Allocation) topic modeling and the BERTopic topic modeling method, it was confirmed that BERTopic is a superior method to LDA.