• Title/Summary/Keyword: 디젤발전기

Search Result 196, Processing Time 0.027 seconds

Analysis and Evaluation Study on Diesel Generator Engine Operation Signature (디젤발전기 엔진 운전상태 분석 및 평가방법에 대한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.5
    • /
    • pp.82-88
    • /
    • 2009
  • The purpose of this paper is to provide technical background, techniques and actual diesel engine signature analysis evaluation result. Engine signature analysis(ESA) is a process for monitoring the material condition of diesel engine using external sensors, eliminating the need to periodically disassemble the engine. ESA is also used to balanced the engine. Engine balancing is the process of tuning the engine so that all cylinders carry equal load. ESA is a useful tool to non-intrusively determine the operability and performance and assessment of the material condition of internal component of a diesel engine.

  • PDF

영광1,2,3,4호기 비상디젤발전기 종합신뢰도 분석

  • 김영호;최광희;정현종
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.115-121
    • /
    • 2000
  • 영광1,2,3,4호기 비상디젤발전기(EDG)의 신뢰도 수준을 파악하기 위하여 시험관리대장과 운전불능관리대장, 그리고 발전과장일지를 조사하여 신뢰도 및 이용불능도를 분석하였다. 신뢰도는 EDG의 유효시험 데이터를 이용하여 계산하는 유효 신뢰도와 무효시험까지 포함하여 계산하는 전체 신뢰도로 구분하였으며, 이용불능도는 EDG를 정비모드로 전환시키고 작업함으로서 이용불능을 유발하였던 정비 이용불능도, 그리고 유효시험 실패로 인하여 정비모드를 유발하는 경우에 잠재적 고장 시간까지 포함한 종합 이용불능도로 구분하였다. 분석 결과로서 영광1호기 EDG의 유효 신뢰도는 0.995, 2호기는 1.0으로 매우 높은 수준을 유지하고 있었으며, 이용불능도의 역인 이용가능도는 1호기 A계열 EDG는 0.978, B계열은 0.979, 2호기 A는 0.991, B는 0.976으로 높은 수준이었다. 3,4호기 EDG의 유효 신뢰도는 1,2호기와 마찬가지로 높은 수준이었으나, 전체 신뢰도는 텐덤형 디젤엔진이 갖는 근본적 부하불균형 문제 때문에 낮은 수준이었다. 따라서, 영광3,4호기 EDG의 신뢰도를 높이기 위해 많은 노력을 기울였으며, 이를 통해 EDG 신뢰도 개선에 도움이 된 것으로 분석되었다.

  • PDF

Development of EBOP element technologies for MCFC backup system (MCFC 백업용 EBOP 요소기술 개발)

  • Ryu, Sunglay;Oh, Euntae;Jeong, Jahoon;Hwang, Jungtae;Cha, Inho;Kwak, Cheolhun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.92-92
    • /
    • 2010
  • 여수 국가산업단지, 삼성전자 정전사례에서 볼 수 있듯이 대규모 정전사고는 수백억 이상의 경제적 손실이 뒤따른다. 공장 내에 자체 발전소가 있지만 매번 이런 사고가 재연되어 근본적인 해결책이 필요한 상황이다. UPS 및 디젤발전기를 사용하는 경우, 정전사고로 시 UPS DC bus전압이 일정 수준 이하로 떨어지면 발전기가 기동하여 에너지를 공급하는데 발전기의 특성에 따라 전압의 변동이 심하고 초기기동실패 사례가 종종 보고되고 있다. 본 연구는 연료전지와 전력저장장치의 연계를 통해 산업설비에 안정적으로 전원을 공급하고자 하는 방법에 관한 것으로 연계 제어 로직개발과 Load Leveler, Compensator, STS 등 구성요소 개발을 주요 연구 내용으로 하고 있다. 고온형 연료전지의 열적 안정성을 유지하면서 독립전원의 부하 변동에 대응하기 위한 부가 설비가 기존 제품에 추가 장착되어야 하며, 연계 제어 알고리즘의 확보를 위하여 연료전지 모델링 및 통합시스템 시뮬레이션을 수행하였다. 본 연구에서는 이상과 같은 시뮬레이션 및 백업 모듈 설계 결과를 제시하고자 한다.

  • PDF

The calculation of ESS optimal capacity in Microgrid (Microgrid에서의 ESS최적용량 산정)

  • Son, Hyun-Il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.619-620
    • /
    • 2015
  • 본 논문은 독립형 마이크로그리드 환경에서의 신재생에너지원의 출력 안정화 및 디젤발전기의 최소 사용을 통한 경제적인 운영을 위해 필요한 ESS(Energy Storage System)의 도입을 위한 용량 산정 및 SOC에 따른 충/방전 알고리즘을 제안한다. 제안한 산정 알고리즘을 통해 도서지역의 독립형 마이크로그리드의 데이터를 활용하여 ESS 용량을 산정하고, 이에 대한 효과를 검증한다.

  • PDF

Numerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler (8kW급 디젤발전기 소음기 내부 유동에 관한 수치해석)

  • Yi, Chung Seob;Lee, Tae Eui;Lee, Chi Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.45-50
    • /
    • 2018
  • From the flow analysis of the silencer for 8 kW diesel generators, the following results were obtained. For silencer-1, it was confirmed that the holes formed at the inlet-side portion connect into the exhaust pipe in the chamber. The exhaust pipe installed inside silencer-1 was integrally connected through the holes in the chamber. As a result, it was confirmed that the pressure inside the chamber was kept stable. It was confirmed that the pressure loss generated inside an absorptive type silencer such as silencer-2 was small. The differential pressure of the inlet-outlet of silencer-1 and silencer-2 was confirmed to be 494 Pa at 15 m/s, 859 Pa at 20 m/s, 1326 Pa at 25 m/s, and 1911 Pa at 30 m/s.

A Study on Methodology of Optimal Operation of BESS and Diesel Generators in a Microgrid Considering Efficiency Characteristics According to the Power Ratios of Diesel Generators (디젤발전기의 출력비에 따른 효율을 고려한 마이크로그리드에서의 BESS와 디젤발전기의 최적 운영 기법에 관한 연구)

  • Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.539-546
    • /
    • 2016
  • With the growing interest of microgrid systems all over the world, many studies on microgrid operation are being carried out. The battery energy storage system(BESS) and the diesel generator are key equipments in the microgrid. In this paper, we analyze the characteristics of fuel consumption according to the power ratio of the diesel generator. Then, the formula to represent the unit cost of generation according to the power ratio of the diesel generator is derived. A new modeling of battery operation is presented considering the lifetime reduction according to increasing the cycles of charge/discharge operation of the battery. The methodology of determining the optimal operation of the battery and the diesel generator is presented by the use of the formula of fuel consumption of the diesel generator and the new modeling of battery operation. It is shown that this optimization methodology can be applied effectively for economical operation of the BESS and the diesel generator of a microgrid by case studies.

Study on Prediction of Performance with Design Variables of Solar-Assisted Still Using Waste Heat from Diesel Generator (디젤 발전기 폐열을 활용한 태양열원 해수담수기의 설계변수에 따른 성능 예측에 관한 연구)

  • Jang, Hyun;Yi, Chung Seob;Suh, Jeong Se;Jeong, Kyoung Yul;Park, Change Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1061-1068
    • /
    • 2013
  • This study predicts distillate productions according to design variables by numerical analysis when the waste heat from a diesel generator is added to the solar-assisted still proposed in a previous study. Mathematical models were set up in reference to previous studies, and the amount of heat exchange from the waste heat recovery pipe was considered. To ensure the reliability of numerical analysis, the result was compared with that of a previous study and then, the distillate productions according to design variables were obtained by the analysis model. The results were found to generally be in agreement, and the increasing amount of distillate production of the still with the added waste heat was confirmed. In addition, the optimal value of the tilt angle of glass cover and the number of cells were determined by numerical analysis.

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.