• Title/Summary/Keyword: 디옵터

Search Result 16, Processing Time 0.024 seconds

The Visual Acuity and Refraction on Students of Primary School Using Eyeglasses in Kyung-Nam Region (경남지역 안경 착용자 초등학생들의 시력과 굴절)

  • Kim, Douk-Hoon;Mun, Joung-Hak;Kim, Joung-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.345-350
    • /
    • 2006
  • The study of the visual acuity and refraction status was performed to the students of primary school using eyeglasses in Kyung Nam region, Korea. Two hundred sixty three subjects with various styles of ametropia were analyzed the visual acuity and refraction examination by the subjective and objective tools. The results of study were as follows; 1) According to the increase of age of subjects, the visual acuity of binocular in naked eyes was decrease. However ametropia was increase. 2) The high frequency of ametropia types in the binocular was simple myopia, and the next order of high frequency was mixed astigmatism, myopic compound astigmatism, simple hyperopia, and hyperopic compound, respectively. 3) On the power of spherical refractive error of ametropia, the high frequency was -1.00 diopter, and the next order of high frequency was -2.00 diopter, +2.00 diopter, -3.00 diopter, and so on, respectively. 4) According to the increase of subjects ages, the changes of dioptric power of myopic spheric power was increase. however the frequency of the boy and girl was similar results, also the dioptric values of refractive status in binocular was similar results. As the results of this study, we conclude that the relationship of the visual acuity and refractive error status in primary students using eyeglasses was improved.

  • PDF

Thermal Deformation Measurement Spherical Glasses Lens Using ESPI (ESPI를 이용한 안경용 렌즈의 열변형 측정)

  • Kim, Koung-Suk;Jang, Ho-Sub;Kim, Hyun-Min;Yang, Seung-Pill
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2008
  • The spherical glasses lenses are typically classified into two groups such as (+) diopter lens and (-) diopter lens by the refractive power index. The thermal deformation of a lens is occurred by external heat source and is changed respected to the diopter of a lens. In this paper, the thermal deformation of spherical glasses lenses were quantitatively measured by using ESPI (electronic speckle pattern interferometry) which has an advantage that the non-contact, non-destructive and precise deformation measurement is available due to the coherency characteristic. The temperature changes were measured by IR camera. It makes experiments over 14 types of the plastic glasses lenses. From the results, it was confirmed that the larger diopter lens showed the less thermal deformation in case of the (+) diopter lens. On the other hand, the thermal deformation of the (-) diopter lens was measured with uniform pattern when the same temperature changes were applied. Also, it was found that the thermnal deformation of the (+) diopter lens is less than that of the (-) diopter lens. Therefore, it is expected that when the thermal deformation is occurred to the various types of the lens, the variation of the focal length caused by the thermal distortion of a lens would be measured quantitatively.

A Study on the Phoria of Korean Male and Female Adults (한국인 성인 남녀의 사위에 관한 연구)

  • Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • Once refractive error of the eye was fully corrected. Polarization Test was used to investigate binocular vision function. As the results of phoria measurement of Korean adults for 53males and 59 females, orthophoria in 27.68%, esophoria in 12.50%, exophoria in 48.21%, verical phoria in 3.75%, esophoria(+verical phoria) in 2.68%, and exophoria(+vertical phoria) in 5.36%, respectively. Horizontal phoria is below $3{\Delta}$ mostly and verical phoria is below $1{\Delta}$.

  • PDF

Out-of-plane Deformation Measurement of Spherical Glasses Lens Using ESPI (ESPI를 이용한 구면 안경렌즈의 면외 변형 측정)

  • Yang, Seung-Pill;Kim, Kyoung-Suk;Jang, Ho-Sub;Kim, Hyun-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.77-81
    • /
    • 2007
  • The spherical lens is typically classified by the refractive power into two groups such as (+) diopter lens and (-) diopter lens. The deformation occurred by the external force that is applied to a lens is caused by the increase or the decrease in the diopter of a lens. In this paper, the deformation of the lens was quantitatively measured by using ESPI (Electronic Speckle Pattern Interferometry) which have been used in the optical measurement field for past few years. ESPI has an advantage that the deformation of an object can be measured precisely by using coherence of the light. The experiment was carried out to the totally 16 types of plastic lens. It was confirmed that the deformation was decreased by increasing the diopter of the lens when same displacement was applied to the lens in case of (+) diopter lens and was increased by decreasing the diopter of the lens in case of (-) diopter lens. Also, it was found that the deformation of (+) diopter lens is less than that of (-) diopter lens. Therefore, with these results, it is expected that the possibility of the quantitative measurement for variation of the optical defect caused by the deformation of a lens when the deformation is occurred to the various types of the lens can be presented and that the application in the lens industrial field can be performed.

  • PDF

Refractive Error Induced by Combined Phacotrabeculectomy (섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Park, Ji Hae;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1173-1180
    • /
    • 2018
  • Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. -0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (-1.07 vs. -0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy.

Injury of the Medial Rectus Muscle by Using a Microdebrider During Endoscopic Sinus Surgery: A Case Report

  • Choi, Yoon-Seok;Bai, Chang-Hoon;Song, Si-Youn;Kim, Yong-Dae
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.2
    • /
    • pp.240-246
    • /
    • 2006
  • A microdebrider is increasingly used in endoscopic sinus surgery. Although it has many advantages over conventional instruments, it has been associated with severe complications. We treated a case of rupture of the left medial rectus muscle after use of a microdebrider during endoscopic sinus surgery in a 50 year-old female patient who complained of binocular diplopia and exotropia. The patient showed marked limitation on adduction and about 40 prism diopters of left exodeviation. The orbital computed tomography showed a bony defect at the left medial orbital wall, and injury of the medial rectus muscle. The exodeviation was corrected after ophthalmologic surgery. We report a case of the rupture of the medial rectus muscle after use of a microdebrider during endoscopic sinus surgery and review the medical literature.

  • PDF

A Narrow Band MILES Detection System With Reduced Blind Angle of Detection Using Refractors (굴절체를 이용하여 감지 사각 문제를 개선한 협대역 마일즈 감지 시스템)

  • Ki, Hyeon-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.7
    • /
    • pp.10-16
    • /
    • 2012
  • In this paper, we tried to realize a next generation MILES detection system which is robust to optical noise using a narrow band interference optical filter. Applying a narrow band interference optical filter which has the wavelength range of 895~915nm to the LASER wavelength of 900nm, we could obtain detection characteristics robust to strong optical noise which can be occurred in street battles. However, the MILES detection system has the blind range of detection in the incident angle range of $30^{\circ}{\sim}90^{\circ}$. To solve this problem we proposed a method of incident angle scatter using refractors. Applying a concave meniscus lens refractor which has diopter of 5.4 to the MILES detection system, we could eliminate the blind angle of detection.

An Epidemiologic Survey of Strabismus and Nystagmus in South Korea: KNHANES V (인구역학적 요인에 따른 한국인의 사시 및 눈떨림 유병률 조사: 제5기 국민건강영양조사 자료)

  • Lee, Ji Eun;Kim, Chang Zoo;Nam, Ki Yup;Lee, Seung Uk;Lee, Sang Joon
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.11
    • /
    • pp.1260-1268
    • /
    • 2017
  • Purpose: Strabismus affects any age and represents various functional or non-functional eye problems. This population-based study was conducted to determine the prevalence of strabismus and nystagmus in South Korea according to various sociodemographic factors. Methods: We acquired data from the Korea National Health and Nutrition Examination Survey, a nation-wide cross-sectional survey and examinations of the non-institutionalized civilian population in South Korea (n = 30,538), conducted from July 2008 to December 2011. The prevalence of strabismus and nystagmus were verified, and associated sociodemographic factors was evaluated. Results: The overall prevalence of strabismic disorder in participants over 3 years of age was $1.4{\pm}0.1%$ (95% confidence interval [CI] 1.3-1.6%; $1.5{\pm}0.1%$ in males, $1.3{\pm}0.1%$ in females). The prevalence of exodeviation (15 or more prism diopters), esodeviation (10 or more prism diopters), vertical deviation, and other complicated strabismus and nystagmus was 1.0%, 0.2%, 0.2%, 0.1% and 0.1% respectively. The prevalence was highest in the 6 to 15-year age group ($1.9{\pm}0.3%$), and lowest in the 40 to 49 years age group ($0.8{\pm}0.1%$) (p = 0.005). There were no statistically significant differences for gender, region, residential area, household income, educational level and occupation. Conclusions: This nation-wide epidemiologic study demonstrated that the prevalence of strabismus and nystagmus according to various sociodemographic factors in South Korea was not statistically significant except for age group. Further investigations are required based on more surveys to better recognize the etiologic or risk factors that may be related to strabismus and nystagmus.

Relationship Between the Degree of Exophoria and Stereoacuity (외사위의 정도와 입체시의 관계)

  • Shin, Hoy-Sun;Lee, Sun-Haeng;Yun, Mi-Ok;Kim, Mi-Yeon;Bea, Hong-Sup;Park, Sang-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • Purpose: Stereopsis is one of primary characteristics for assessment of binocular function. The purpose of this study was to determine the possible relationship between the degree of exophoria and stereoacuity at near. Methods: 110 exophores (male n=71, female n=39, mean $age{\pm}SD=11.30{\pm}1.47$ years) without amblyopia, strabismus, and ocular and systemic pathology were studied. Subjects were also excluded if they had visual acuity poorer than 0.8 in either eye or vertical phoria greater than 1 prism diopter. Clinical tests were performed for near phorias by von Graefe technique using a Digital Refractor (CDR-3100, Huvitz, Korea) with chart (Predio CDC-4000, Huvitz, Korea), and for stereoacuity using the Titmus fly. Results: A one-way analysis of variance revealed that mean values of the stereoacuity classified according to the degrees of the exophoria were not significantly different (p>0.05). Conclusions: Based on the result of this study, it was found that there was no relationship between the degree of exophoria and stereoacuity.

  • PDF

A Study about How to Design the Rim of Spectacle Frame - Focused on the DESIGN Method of the Rim - (안경테의 프론트 설계 방법에 대한 연구 - 림(Rim) 설계 방법 중심으로 -)

  • Kang, Min-Soo;Kim, In-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.37-42
    • /
    • 2008
  • Purpose: The objective of the study: At present, the spectacles, with its use as a medical aids or a fashion trimming, are recognized as one of the living necessities which can't be separated from human body. One of the features of spectacles is that it must be worn on any part of human body. Such a feature has to be satisfied under the condition an user keeps feeling comfortable with the rim of spectacles worn. In order to ensure meeting this condition, a criterion has to be arranged for the design of the rim of spectacles. In order to manufacture a rim of spectacles which allows an user to secure a comfortable range of vision as well as enhancing the feeling when to be worn, a manufacturing standard has to be established based on optical science. No precise rim of spectacles could be made from the manufacturing method depending on the manufacturer's sensibility. When the rim of spectacles was manufactured according to the incorrect standards, it may cause an user such a fatal result as myopia, hyperopia or astigmatism. Methods: This study focuses on providing a detailed explanation about the design of rim, which is the most important element during designing a rim of spectacles, making use of the optical elements of spectacles, and helping the manufacturers and the people who work in the spectacles-related business understand and recognize what is correct and exact and then leading them to establish a standard in respect to the manufacture and selection of spectacles. Results, Conclusions: Considering the fact there happen many errors in relation with the names of rim stipulated in the provisions of International Standards Organization (ISO), due to wrong interpretation by some of the rim manufacturers, the right interpretation should be given about the bridge which is directly connected to rim, so that the rims of spectacles manufactured in Korea could keep a favorable position in competing with the foreign products of same kinds.

  • PDF