• Title/Summary/Keyword: 등온

Search Result 1,142, Processing Time 0.032 seconds

Characteristics of Batch and Continuous Operation in Sr ion Removal from Aqueous Solution Using NaA Zeolite (NaA 형 제올라이트를 이용한 수중의 Sr 이온 제거에서 회분식 및 연속식 운전 특성)

  • Kam, Sang-Kyu;Lee, Chang-Han;Lee, Min-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.9
    • /
    • pp.505-512
    • /
    • 2017
  • The adsorption characteristics of Sr ion in aqueous solution was examined using zeolite NaA powder (Z-PA) and pellets (Z-BA). In batch experiment, the adsorption of Sr ions by Z-BA and Z-PA was well expressed by pseudo-second-order kinetic model than psedo-first-order kinetic model. Experimental isotherm results was well fitted to Langmuir isotherm model and the maximum adsorption capacities obtained from Langmuir isotherm model were 233.32 mg/g for Z-PA and 164.60 mg/g for Z-BA, respectively. The continuous experiment results showed that the total Sr ion uptake (q) increased, but the breakthrough time, effluent volume ($V_{eff}$) and total removal (R) of Sr ion decreased with the Sr ion concentration. The breakthrough curves obtained from the experiment was modeled by Thomas model.

Study on Adsorption of Pb and Cd in Water Using Carbonized Water Treatment Sludge (탄화 정수 슬러지를 이용한 수중의 납과 카드뮴 흡착에 관한 연구)

  • Kim, Younjung;Kim, Daeik;Choi, Jong-Ha;Hong, Yong Pyo;Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.5
    • /
    • pp.238-243
    • /
    • 2017
  • In this study, water treatment sludge carbonized with $400^{\circ}C$ was tested as an adsorbent for the removal of Pb and Cd in water. The carbonized sludge was characterized by thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), X-ray fluorescence spectrometry (XRF), and surface area analysis. Carbonized sludge exhibited much higher specific surface area and total pore volume than water treatment sludge itself. In batch-type adsorption process, carbonized sludge represented better adsorption performance for Pb than Cd, achieving 90~98% at the concentrations conducted in the experiments. Equilibrium data of adsorption were analyzed using the Freundlich and Langmuir isotherm models. It was seen that both Freundlich and Langmuir isotherms have correlation coefficient $R^2$ value larger than 0.95. The results of studies indicated that carbonized water treatment sludge by heat treatment could be used as an efficient adsorbent for the removal of Pb and Cd from water.

Adsorption Characteristics of 2,4-Dichlrophenol by Magnetic Activated Carbon Prepared from Waste Citrus Peel (폐감귤박으로 제조한 자성 활성탄을 이용한 2,4-디클로로페놀의 흡착특성)

  • Kam, Sang-Kyu;Lee, Min-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.4
    • /
    • pp.388-394
    • /
    • 2018
  • The removal of 2,4-dichlorophenol (2,4-dichlorophenol, 2,4-DCP) in aqueous solution was studied using the magnetic activated carbon (MAC) prepared from waste citrus peel. The adsorption characteristics of 2,4-DCP by MAC were investigated by varying the contact time, MAC dose, solution temperature, pH and 2,4-DCP concentration. The isothermal adsorption data were well explained by the Langmuir isotherm model equation and the maximum adsorption capacity calculated from the Langmuir isotherm equation was 312.5 mg/g. The adsorption kinetic data were well described by the pseudo-second-order reaction equation. The intraparticle diffusion model data indicated that both the film and intraparticle diffusion occur simultaneously during the adsorption process. The thermodynamic parameters of ${\Delta}H^o$ and ${\Delta}G^o$ have positive and negative values, respectively, indicating that the adsorption of 2,4-DCP by MAC is a spontaneous endothermic reaction. After the adsorption experiment was completed, the used MAC could be easily separated by an external magnet.

Adsorption Characteristics of Antibiotics Amoxicillin in Aqueous Solution with Activated Carbon Prepared from Waste Citrus Peel (폐감귤박으로 제조한 활성탄을 이용한 수중의 항생제 Amoxicillin의 흡착 특성)

  • Kam, Sang-Kyu;Lee, Min-Gyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.4
    • /
    • pp.369-375
    • /
    • 2018
  • Batch experiments were conducted to investigate the effects of operating parameters such as the temperature, initial concentration, contact time and adsorbent dosage on the adsorption of antibiotics amoxicillin (AMX) by waste citrus peel based activated carbon (WCAC). The kinetics and isotherm experiment data can be well described with the pseudo-second order model and the Langmuir isotherm model, respectively. The maximum adsorption capacity of AMX by WCAC calculated from the Langmuir isotherm model was 125 mg/g. The adsorption of AMX by WCAC shows that the film diffusion (external mass transfer) and the intraparticle diffusion occur simultaneously during the adsorption process. The adsorption rate is more influenced by the intraparticle diffusion than that of the external mass transfer as the particle size of WCAC increases, and the intraparticle diffusion is the rate controlling step. The thermodynamic parameters indicated that the adsorption reaction of AMX by WCAC was an endothermic and spontaneous process.

Fabrication and performance and stability tests of Bi-2223 pancake magnet

  • Sohn, M.H.;Cha, M.K.;Lee, J.K.;Cho, Y.S.;Ha, H.S.;Jang, H.M.;Lee, N.J.;Kim, B.J.;Kim, H.K.;Kim, Y.C.;Jeong, D.Y.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.241-247
    • /
    • 2000
  • 77 K와 self-field에서 22 A 의 Ic 를 갖는 길이 120 m, 19-심 Bi-2223상 선재를 제조하여, 두 개의 double pancake 코일로 구성된 proto-type 고온초전도 자석을 설계, 제작하여 이 자석에서의 4.2 K와 77 K에서의 I-V 특성과 운전 특성을 평가한 결과, 이 자석은 77 K 등온조건에서는 9.5 A 의 Ic를, 77 K 헬륨가스 속에서는 8.3 A 의 Ic를 나타내었고, 4.2 K 등온조건에서는 93.7 A 의 Ic와 102 A 의 Iq를, 4.2K헬륨가스 속에서는 88.4A의 Ic 와 92.0 A 의 Iq를 나타내어, 이 자석은 4.2 K 와 77 K 의 등온조건에서 각각 0.58 T 와 0.06 T 의 자장을 발생하였는데, 이는 해석적 방법으로 계산한 결과와 잘 일치하였다. 그리고 이 자석이 전도냉각되어 4.2 K 에서 운전될 때의 안정성 특성평가로서, Ic 보다 약간 큰 전류인 89 A 를 인가한 결과, 전류인가 후 82.6초 후에 quench가 발생하였는데, 이 quench는 네 번째 pancake의 전류도입선부 연결부에서와 약간 늦지만 첫 번째 pancake의 전류도입선부 연결부에서 거의 동시에 개시되어 전체로 파급된 것으로 사료되었는데, Ic 가 낮은 첫번째 pancake에서 더 높은 전압 강하가 나타났다. 또한 장착된 heater를 통하여 77 K 에서 8.9 A 의 전류로 운전되고 있는 코일에 146 joule 의 열을 가했을 때 quench 가 일어났는데, 이때 quench 는 방위각 방향의 Bi-2223/Ag 선재를 따라서 보다 Kapton 절연층을 관통하는 선재의 반경방향으로 훨씬 빨리 전파하였다.

  • PDF

Diffusion-controlled Cure Kinetics of High Performance Epoxy/Carbon Fiber Composite Systems (확산속도에 따라 한계경화도를 갖는 에폭시/탄소섬유 복합재료의 경화반응 속도 연구)

  • 박인경;금성우;이두성;김영준;남재도
    • Polymer(Korea)
    • /
    • v.24 no.1
    • /
    • pp.105-112
    • /
    • 2000
  • Using a commercial epoxy/carbon fiber composite prepreg (DMS 2224) as a model system, the cure kinetics of vitrifying thermoset system were analyzed by isothermal and dynamic-heating experiments. Focusing on the processing condition of high performance composite systems, a phenomenological kinetic model was developed by using differential scanning calorimetry (DSC) and reaction kinetics theories. The model system exhibited a limited degree of cure as a function of isothermal temperature seemingly due to the diffusion-controlled reaction rates. The diffusion-controlled cure reaction was incorporated in the development of the kinetic model, and the model parameters were determined from isothermal experiments. The first order reaction was confirmed from the characteristic shape of isothermal cure thermograms, and the activation energy wes 78.43 kJ/mol. Finally, the proposed model was used to predict a complex autoclave thermal condition, which was composed of several isothermal and dynamic-heating stages.

  • PDF

A Feasibility Study on the Development of Admixed Liner Using Gibbsite and Clay (Gibbsite 를 이용한 대체 차수재 개발 타당성 연구 - Batch Test를 통한 흡착실험을 중심으로 -)

  • 현재혁;이상현;이지훈
    • The Journal of Engineering Geology
    • /
    • v.5 no.1
    • /
    • pp.75-93
    • /
    • 1995
  • This study investigates the adsorption capacity of the gibbsite and the clay on the development of admixed liner. The gibbsite is produced as a by-product in the pretreatment process for cleaning and coloring of Alurninurn sash. From the study, following conclusions were obtained: 1) The adsorption of metals such as Cu(II), Cd(II), and Ni(II) and phenol on gibbsite and l:entonite was equilibrated rather quickly(12 ~48 hrs ). 2) The rate and extent of adsorption is a function of surface area the adsorbent having. 3) The Larigmuir isotherm is found to be more suitable than Freundlich isotherm for the adsorption analysis of heavy metals on gibbsite and bentonite. 4) In case of phenol, Freundlich isotherm, whose N value is close to 1, i.e., close to linear isotherm, is more fit to describe the adsorption on gibbsite and bentonite. 5) The amount of metals and phenol adsorbed is found to be in the following order : Adsorbent : $2{\mu}m-Al(OH)_3$ > Mixed Solid > $12{\mu}m-Al(OH)_3$ > Na-Bentonite > $30{\mu}m-Al(OH)_3$

  • PDF

The Design and Implementation of Isotherm and Isohaline Forecast System using Temporal GIS (TGIS 개념을 이용한 등온선 및 등염분선 예측시스템의 설계 및 구현)

  • Kwak, Ho-Young
    • Journal of Internet Computing and Services
    • /
    • v.1 no.1
    • /
    • pp.73-86
    • /
    • 2000
  • The Geographic Information System (GIS) is a system that collects, stores, analyzes and processes geographic object data existing in space. The GIS is widely used in application fields related to geography such as city planning, land-register management, forest resources management, etc. The importance and necessity of the GIS have been well demonstrated, and therefore many studies on this system have been carried out. However, most of those studies have just treated geographic information as spatial information, but have not considered or have overlooked changes of spatial data dependent on time. For example, transportation information management and atmospheric phenomena forecast, have not exactly reflected the actual world which changes with the flow of time. In this thesis, a temporal GIS is established to effectively and precisely process information on space objects changing with time and a database is built up in reference to changes in water temperature and salinity. And the isotherm and isohaline forecast system implemented to support graphical tool.

  • PDF

Loop-mediated Isothermal Amplification (LAMP) for Detection of Streptococcus parauberis (Loop-mediated isothermal amplification (LAMP)법을 이용한 Streptococcus parauberis 의 신속 진단)

  • Moon, Kyung-Mi;Kim, Dong-Hwi;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.24 no.4
    • /
    • pp.428-436
    • /
    • 2014
  • Loop-mediated isothermal amplification (LAMP) technique relies on autocycling strand displacement DNA sysnthesis without template denaturation steps under isothermal conditions. LAMP has more advantages than modern PCR, as it requires only basic laboratory equipment like an isothermal water bath, oven, and heating cabinet. Hence, in this study, five random primers were designed with Streptococcus parauberis, shikimate kinase Arok gene sequences (Genbank accession number: CP0024711). Two primers were selected based on the ladder pattern. Other optimum reaction conditions like temperature, time, and sensitivity were established and confirmed with conventional SYBR-green PCR. Results confirmed that the designed random primers were species specific, without any non-target DNA amplification under isothermal conditions. Hence, this study suggests that LAMP techniques could be used in the diagnosis of fish pathogen, specifically S. parauberis.

H2S Adsorption Characteristics of KOH Impregnated Activated Carbons (KOH 첨착 활성탄에서 황화수소의 흡착 특성)

  • Choi, Do-Young;Jang, Seong-Cheol;Gong, Gyeong-Tack;Ahn, Byoung-Sung;Choi, Dae-Ki
    • Applied Chemistry for Engineering
    • /
    • v.17 no.3
    • /
    • pp.280-285
    • /
    • 2006
  • Adsorption characteristics of $H_{2}S$ on KOH impregnated activated carbon were evaluated using dynamic adsorption method in a fixed bed. The pore properties, including BET's specific surface area, pore volume, pore size distribution, and mean pore diameter of these KOH impregnated activated carbons, were characterized from $N_{2}$ adsorption/desorption isotherms. Adsorption equilibrium data were correlated with Langmuir and Freundlich isotherms. The adsorption of $H_{2}S$ onto the KOH impregnated activated carbon is better fitted by the Langmuir isotherm. An increase in the content of oxygen affects the performance of KOH impregnated activated carbon to the greatest extent.