• Title/Summary/Keyword: 등분포하중

Search Result 106, Processing Time 0.038 seconds

Shear Behavior of Reinforced Concrete Beams Subjected to Uniform Load (등분포하중을 받는 철근콘크리트보의 전단거동에 관한 연구)

  • Kim, Dae-Jung;Kim, U
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.04a
    • /
    • pp.60-64
    • /
    • 1991
  • The shear behavior of reinforced concrete beams subjected to uniform loading was investigated by testing 1/3 small-scale model R/C beams. The emphasis was placed in finding a fundamental difference in behavior between in uniformly loaded beams and in point loaded beams. The major variable was the span-to-depth ratio, varying from 4 to 12. The concrete strength and steel ratio were fixed.

  • PDF

Application of Variational Method to the Elastic Foundation (변분법에 의한 탄성지반 해석)

  • Lee, Seung-Hyun;Han, Jin-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4642-4647
    • /
    • 2011
  • Solution for elastic foundation of plane strain state was derived by the application of variational method. Functions of the transverse distribution of the displacements for the analysis were chosen as linear functions. Loading conditions considered for the analysis were concentrated load and distributed load. Under the loading condition of the concentrated load, surface displacement was decreased drastically as the distance from the point of the loading increased. Under the loading condition of the distributed load, surface displacements were more uniformly distributed beneath the loading area when the ratio of the half of the loading width to the depth(B/H) of the compressible layer was greater. The surface displacement was more quickly converged from the edge of the loading area as the ratio(B/H) increased.

In-plane buckling strength of fixed arch ribs subjected vertical distributed loading (수직 등분포 하중을 받는 고정 지점 포물선 아치 리브의 면내 좌굴 강도)

  • Moon, Ji Ho;Yoon, Ki Yong;Kim, Sung Hoon;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.439-447
    • /
    • 2005
  • When arch ribs are subjected to vertical loading, they may buckle suddenly towards the in-plane direction. Therefore, the designer should consider their in-plane stability. In this paper, the in-plane elastic and inelastic buckling strength of parabolic, fixed arch ribs subjected to vertical distributed loading were investigated using the finite element method. A finite element model for the snap-through and inelastic behavior of arch ribs was verified using other researchers' test results. The ultimate strength of arch ribs was determined by taking into account their large deformation, material inelasticity, and residual stress. Finally, the finite element analysis results were compared with the EC3 design code.

Numerical Analysis of Large Deflections of Cantilever Beams (캔틸레버 보의 과대처짐 해석)

  • Lee, Byoung Koo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 1990
  • A method is developed for solving the elastica of cantilever beam subjected to a tip point load and uniform load. The Bernoulli-Euler differential equation of deflected beam is used. The Runge-Kutta method and the Regula Falsi method are used to perform the integration of the differential eqution and to determine the horizontal deflection, respectively. The horizontal and vertical deflections of the free end, and the free-end rotations are calculated for a range of parameters representing variations in tip point load and uniform load. All results are presented in nondimensional forms. And some typical elastic are also presented.

  • PDF

Large Displacement Behaviors of Foam-Insulated Concrete Sandwich Panels Subjected to Uniform Pressure (등분포하중에 종속된 폼내장 콘크리트 샌드위치패널의 유한변위거동)

  • Kang, Jun-Suk;Won, Deok-Hee;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.35-43
    • /
    • 2011
  • This study examined the structural behaviors of foam insulated concrete sandwich panels subjected to uniform pressure. Finite element models were used to simulate the detailed shear resistance of connectors and the nonlinear behaviors of concrete, foam and rebar components. The models were then validated using data from static tests performed at the University of Missouri. Both composite and non-composite action had a significant effect on the response of the foam insulated concrete sandwich panels, indicating that the simulated shear tie resistance should indeed be incorporated in numerical analyses. The modeling approach used here conveniently simulated the structural behaviors during all loading stages (elastic, yielding, ultimate and post-failure) and was compatible with the American Concrete Institute (ACI) Code and existing design practices. The results of this study will therefore provide useful guidelines for the analysis and design of foam insulated sandwich panels under both static and dynamic loadings.

A Numerical Study on Inplane Nonlinear Buckling Strengths of New Arches Subjected to Uniformly Distributed Loading (수직등분포하중을 받는 신형식단면 원형아치리브의 비선형 면내좌굴강도에 대한 해석연구)

  • Park, Jong-Sup;Kang, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.399-405
    • /
    • 2012
  • This paper investigates the characteristics of buckling loads for steel arches with new type cross section which is consisted of T-section and pipe-section. A general purpose finite-element program ABAQUS was used to evaluate the inelastic buckling strengths of the arches which included the influence of the geometric and material nonlinearity. According to the comparisons between earlier studies and results from finite-element analyses, new design equations should be developed for the new arches. New buckling factors were developed to consider influence of rise-to-span ratio and boundary conditions. It is found that the presented factors are sufficiently accurate to predict the inplane buckling loads of new type section steel arches subjected to uniformly distributed loading. The proposed equations can be used to investigate new type steel arches subjected to unsymmetrical loading and composited arches.

An Evaluation of Inelastic Behavior of a Cable Supported Bridge under Earthquake Load (지진하중을 겪는 케이블 지지 교략의 비탄성 거동 평가)

  • Lee, Kyoung-Chan;Chang, Sung-Pil
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.104-408
    • /
    • 2003
  • 케이블 장대 교량의 해석에 있어서 기하적인 비선형만을 고려한 해석이 보편적이었다. 하지만 이 연구에서는 내진 해석시 케이블지지 교량이 비탄성적으로 거동 할 수 있기 때문에, 기하적인 비선형 이외에 재료적인 비선형을 고려할 필요가 있음을 보이고자 한다. 극한 하중 상태를 모사하기 위하여 사하중에 하중계수를 곱하여 하중을 증가시켜 중력방향으로 하중을 가하였고, 지진에 대한 하중 상태를 모사하기 위하여 교축방향의 지진 하중에 대한 등가의 등분포 하중과 이의 0.3배에 해당하는 수직 방향 하중을 동시에 가하였다. 이러한 해석을 통하여 자중의 2배 이상의 하중이 가해지면 거더가 비탄성적으로 거동 할 수 있고, 또한 교축 방향과 수직 방향의 설계지진하중을 고려할 경우 수평방향의 구속이 모두 풀리면 주탑이 비탄성적으로 거동 할 수 있음을 알 수 있다. 따라서 케이블지지 교량의 지진 해석시 특정한 경우에 있어서는 비탄성 거동을 고려해야 할 필요가 있을 것으로 보인다.

  • PDF

Programming of Beam/Column Analytical Process for Composite Wall Panels (냉간성형강 스터드 합성벽 패널의 보/기둥 해석기법의 전산화)

  • Lee, Young Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.45-52
    • /
    • 2005
  • The object of this study was a cold-formed steel wall stud panel sheathed by gypsum boards. In the beam-analysis, the panel was treated as a simple beam with a uniform lateral loading. The deflections were calculated by considering the primary factors that reduced the stiffness of the panel. In the column-analysis, the panel was treated as a bearing wall with an axial load. By using an energy method, nominal axial strength could be evaluated by considering both flexural buckling and torsional-flexural buckling. All calculations were programmed and compared with the results of the experiment. In the beam-analysis, experimental deflections were close to theoretical deflections. In the column-analysis, the experimental values were also close to theoretical values in axial strength.

Structural Analysis of Underground Parking Garage Under Vehicle Load (지하주차장 차량하중에 따른 구조체의 영향분석)

  • Kim, Young-Jin;Lee, Bum-Sick;Choi, Dong-Sub;Oh, Hyo-Keon;Kang, Chang-Bum
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.

The Structural Economical Efficiency Evaluation of Partially Restrained Composite CFT Column-to-Beam Connection (합성반강접 CFT기둥-보 접합부 구조의 경제성 평가)

  • Kim, Sun-Hee;Bang, Jung-Seok;Park, Young-Wook;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 2012
  • This study seeks to devise a design application for a beam structure with partially restrained composite connection to a CFT column. A cost-efficient and stable component is applied by adjusting the stiffness ratio of the column connection through partially restrained composite connection. Based on a review of the structure's stability, it was confirmed that in the case of a low-rise building as a moment frame, resistance without bracing is feasible because stiffness increased by virtue of the partial restrained composite connection by composite action. In the case of a high-rise building, lateral resistance load of moment frame was approximately 10% when proper partial restrained rate was at around 60%. With considerations related to economic efficiency, the partial restriction effect of the beam component was significantly activated by the uniform load, but that of the beam activated by concentrated load was not significantly indicative. The analysis indicated that 60% partial restrained girder at the connection was the most economical in the case of uniform load. It also showed that end moments can be reduced by approximately 25%.