• Title/Summary/Keyword: 등가 TMD모델

Search Result 4, Processing Time 0.017 seconds

Control of the Eccentric Building Using a TMD with Torsional Rigidity (비틀림 강성을 가지는 동조질량감쇠기를 이용한 편심건물의 제어)

  • Park, Yong-Koo;Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.65-72
    • /
    • 2012
  • In this stury, control performance of tuned mass damper (TMD) with torsional rigidity for an eccentric structure showing torsional responses is investigated. To this end, an eccentric structure subjected to earthquake excitation is used to evaluate the control performance of torsional TMD by varying installed location and torsional rigidity of TMD, To reduce computational time required for repetitive time history analysis of an example structure having non-proportional damping system due to TMD, an equivalent analytical model is used in this study. Torsional properties of TMD usually neglected in typical TMD are verified to be effective in reduction of torsional responses of the eccentric structure. In the case of eccentric structures, it has been seen that the center of a plane of a structure may not be optimal location of TMD.

Integrated Analysis and Design Technologies for a Structure with Control Devices (구조물-제진장치 통합 해석 및 설계 기술)

  • Lee, Sang-Hyun;Chung, Lan;Kang, Kyung-Soo;Hwang, Jae-Seung;Park, Ji-Hun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.388-391
    • /
    • 2010
  • 본 논문에서는 풍하중을 받는 구조물의 응답을 보다 적극적으로 저감시킴으로써 구조물의 안정성과 사용성을 개선하기위한 능동제어 알고리즘을 송도 자유무역 지구에 건설중인 포스코건설 사옥에 수치해석을 통해 적용하여 그 효과를 검증하였다. 수치해석에 의한 시뮬레이션 결과를 보면 최대 제어력이 제한이 된 비선형 제어기가 LQR 제어기와 등등한 제어효과를 가지고 있는 것으로 나타났으며, 제어력의 측면에서 본다면 비선형 제어기법이 더욱 유리한 것을 알 수 있다. 또한, 본 연구에서는 구조물과 질량형 제진장치의 상호작용을 고려하여 통합적으로 제진효과를 해석하고, 이를 바탕으로 제진장치를 설계할 수 있는 소프트웨어를 개발하였다. 구조물의 모드정보에 기초한 축소모델을 구축하고 제진장치의 설계 및 제진성능 평가를 수행하고 사용성을 평가하게 된다. 전체 소프트웨어는 질량형 제진장치의 설계프로그램과 질량형 제진장치의 종류별 대안설계결과를 등가감쇠비로 표현하여 비교평가하는 두 개의 모듈로 이루어져 있으며 전자는 비제어구조물 해석 모듈 및 TMD, TLD, TLCD, AMD를 대상으로 해석 및 설계를 수행하는 총 5개의 하부 모듈로 구성된다. 본 소프트웨어를 현재 TLCD가 설치되어 있는 인천 송도 국제업무지구의 주상복합건물에 적용하여 TMD, TLD, TLCD, AMD의 대안설계를 실시하였다.

  • PDF

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.11
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.

Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitudes (가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성)

  • Lee, Sung-Kyung;Lee, Hye-Ri;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.842-849
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitudes, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitudes. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass does not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitudes.

  • PDF