• Title/Summary/Keyword: 등가 하중

Search Result 480, Processing Time 0.03 seconds

Design of Individual Pitch Control and Fatigue Analysis of Wind Turbine (풍력발전시스템 개별피치제어설계 및 피로해석에 관한 연구)

  • Jeon, Gyeong Eon;No, Tae Soo;Kim, Guk Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Structural loading on a wind turbine is due to cyclic loads acting on the blades under turbulence and periodic wind field. The structural loading generates fatigue damage and fatigue failure of the wind turbine. The individual pitch control(IPC) is an efficient control method for reducing structural loading. In this paper, we present an IPC design method using Decentralized LQR(DLQR) and Disturbance accommodating control(DAC). DLQR is used for regulating rotor speed and DAC is used for canceling out disturbances. The performance of the proposed IPC is compared with CPC, which was designed with a gain-scheduled PI controller. We confirm the effect of fatigue load reduction with the use of damage equivalent load(DEL).

An Evaluation of Inelastic Behavior of a Cable Supported Bridge under Earthquake Load (지진하중을 겪는 케이블 지지 교략의 비탄성 거동 평가)

  • Lee, Kyoung-Chan;Chang, Sung-Pil
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.104-408
    • /
    • 2003
  • 케이블 장대 교량의 해석에 있어서 기하적인 비선형만을 고려한 해석이 보편적이었다. 하지만 이 연구에서는 내진 해석시 케이블지지 교량이 비탄성적으로 거동 할 수 있기 때문에, 기하적인 비선형 이외에 재료적인 비선형을 고려할 필요가 있음을 보이고자 한다. 극한 하중 상태를 모사하기 위하여 사하중에 하중계수를 곱하여 하중을 증가시켜 중력방향으로 하중을 가하였고, 지진에 대한 하중 상태를 모사하기 위하여 교축방향의 지진 하중에 대한 등가의 등분포 하중과 이의 0.3배에 해당하는 수직 방향 하중을 동시에 가하였다. 이러한 해석을 통하여 자중의 2배 이상의 하중이 가해지면 거더가 비탄성적으로 거동 할 수 있고, 또한 교축 방향과 수직 방향의 설계지진하중을 고려할 경우 수평방향의 구속이 모두 풀리면 주탑이 비탄성적으로 거동 할 수 있음을 알 수 있다. 따라서 케이블지지 교량의 지진 해석시 특정한 경우에 있어서는 비탄성 거동을 고려해야 할 필요가 있을 것으로 보인다.

  • PDF

A Study on Equivalent Design Wave Approach for a Wave-Offshore Wind Hybrid Power Generation System (부유식 파력-해상풍력 복합 발전시스템의 등가설계파 기법 적용에 관한 연구)

  • Sohn, Jung Min;Shin, Seung Ho;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.135-142
    • /
    • 2015
  • Floating offshore structures should be designed by considering the most extreme environmental loadings which may be encountered in their design life. The most severe loading on a wave-offshore wind hybrid power generation system is wave loads. The principal parameters of wave loads are wave length, wave height and wave direction. The wave loads have different effects on the structural behavior characteristic depending on the combination of wave parameters. Therefore, the process of investigation for critical loads based on the individual wave loading parameter is need. Namely, the equivalent design wave should be derived by finding the wave condition which generates the maximum stress in entire wave conditions. Through a series of analysis, an equivalent regular wave height can be obtained which generates the same amount of the hydrodynamic loads as calculated in the response analysis. The aim of this study is the determination of equivalent design wave regarding to characteristic global hydrodynamic responses for wave-offshore wind hybrid power generation system. It will be utilized in the global structural response analysis subjected to selected design waves and this study also includes an application of global structural analysis.

A study on design and structural strength analysis for the rake of rotary screeners (로터리 제진기의 Rake에 대한 설계 및 구조강도해석에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.210-215
    • /
    • 2017
  • This study examined the mechanical design and the structural strength analysis of the rake used in a rotary screener. For the case of the mid-water part, an additional load condition was given by calculating the underwater frictional force generated by the water. For the upper-water part, the analysis was done by dividing the 500kg additional load into the left-concentrated load, center-concentrated load, and right-concentrated load depending on the location of the attached narrow material, and it was determined that all 3 additional load conditions were free from plastic deformation and were secure. The additional load that can occur from the weight of the attached narrow material was divided into three, 1,000kg, 1,300kg, and 1,500kg, and then analyzed. The results of the analysis show that in the case of 1,000kg and 1,300kg, an equivalent strength of 143.6MPa and 186.6MPa occurred, respectively. These figures are lower than the yield strength of the STS304 used in the rotary screener. Therefore, plastic deformation does not occur and is considered to be secure. In the case of 1500kg, however, the equivalent strength that occurred was 215.41MPa, which is greater than the yield strength of STS304, and was judged to be unsafe.

An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading (실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구)

  • 심재욱;박근보;최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.329-337
    • /
    • 2002
  • Based on the equivalent uniform stress concept presented by Seed and Idriss, sinusoidal cyclic loads which simplified the earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. In this study, the criterion of the liquefaction resistance strength was determined by applying real earthquake loading to the cyclic triaxial test. From the test results, relationships between liquefaction behaviors of saturated sand and earthquake characteristics such as magnitude or time-duration were determined. Magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were also proposed.

Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis (연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석)

  • Choi, Kyung-Soo;Park, Seong-Hun;Lee, Jae-Hoon;Huh, Jung-Bo;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.111-118
    • /
    • 2013
  • Purpose of present study is to investigate the effects of thread pitch in coronal portion in scalloped implant with 2 different connections on loading stress using 3 dimensional finite element analysis. Scalloped implant with 4 different thread pitches (0.4mm, 0.5mm, 0.6, and 0.7mm) in the coronal part was modeled with 2 different implant-abutment connections. Platform matching connection had the same implant and abutment diameter so that they were in flush contact at the periphery while platform mismatching connection had smaller abutment diameter than implant so that their connection was made away from periphery of implant-bone interface. Occlusal loading of 100N force was applied vertically and 30 degree obliquely to all 8 models and the maximum von Mises bone stress was identified. Loading stress as highly concentrated in cortical bone. Platform mismatching scalloped implant with small thread pitch (0.4mm) model had consistently lowest maximum von Mises bone stress in vertical and oblique loads. Platform matching model had lowest maximum von Mises bone stress with 0.6mm thread pitch in vertical load and with 0.4mm thread pitch in oblique load. Platform mismatching connection had important roles in reducing maximum von Mises bone stress. Scalloped implant with smaller coronal thread pitch showed trend of reducing maximum von Mises bone stress under load.

Design of a Thrust Stand Using Flexure (플렉셔를 적용한 추력 시험대 설계)

  • Jin, Juneyub;Park, Youngseok;Lee, Changwook;Jeong, Sangseop;Lee, Juhyung;Baek, Cheulwoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.3
    • /
    • pp.205-212
    • /
    • 2021
  • In this study, two types of thrust stand modeling were proposed for the design of a thrust stand using flexure. Type A model generate combined load for tangential (thrust) and axial compressive load (self weight). And type B generate combined load for tangential and axial tensile load. The research was done by comparing the influence of the load between the models through a 1D calculation and computational analysis. The 1D calculated value and the computational analysis value were compared for a total of 10 sections and the results were confirmed to be very similar. In order to prove the validity of the analysis results, the equivalent stress was confirmed from the computational analysis of the flexure, and the production of the Type B model was selected from the evaluation of the yield condition (Von-Mises Yield Criterion).

Effect of Loading Frequency Dependent Soil Behavior on Seismic Site Effect (하중의 주파수에 의하여 지배받은 흙의 동적 거동이 부지증폭현상에 미치는 영향)

  • Park Du-Hee;Hashash Y.M.A;Lee Hyun-Woo;Kim Jae-Yoen
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.3
    • /
    • pp.23-35
    • /
    • 2006
  • Equivalent linear analysis is widely used in estimating local seismic site effects. The soil behavior in the analysis is often assumed to be rate-independent and is not influenced by the seismic loading frequency. Laboratory results, however, indicate that cohesive soil behavior is greatly influenced by the loading frequency. A new equivalent linear analysis method that accounts for the loading frequency dependent soil behavior is developed and used to perform a series of one dimensional site response analyses. Results indicate that while frequency dependent shear modulus has limited influence on computed site response, frequency dependent soil damping greatly filters out high frequency components of the ground motion and thus results in lower response.

A Study on the Loading Capacity Standard of Bi-directional Pile Load Test (BD PLT) (양방향말뚝재하시험의 재하용량 기준에 관한 연구)

  • Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6C
    • /
    • pp.379-388
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load tests of Mega pile foundations, loading capacity standard is not specified exactly. Therefore there are so many confusions in performing the BD PLT and variations up to maximum 2 times in loading capacity are come out. In this study, standards of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio, loading capacity increasing ratio and sufficiency ratio of design load were analyzed. It could be known that the loading capacity standard of bi-directional pile load test must be defined as 1-directional loading capacity and also must be established as more than 2 times of design load.