• Title/Summary/Keyword: 등가성

Search Result 1,132, Processing Time 0.027 seconds

Research of Residual Strain Calculation of Prestressed Concrete Beam Element (프리스트레스트 콘크리트 보 부재의 잔류변형 산정에 대한 연구)

  • Lee, Duck-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.555-562
    • /
    • 2014
  • To perform performance-based seismic design of buildings, it is necessary clear goal for usage and stability after an earthquake. To clear this goal, it requires a review of the constituent material of the building and, in particular, a member used as an indicator of the residual strain is useful. There are more usage of prestressed concrete because of prestressing steel witch has characteristics of the origin-oriented. In this study, the goal is estimating of residual strain on the prestressed concrete beam member. The expression for angle of deformed prestressed concrete beam member was obtained from using of curvature on the critical section and the equivalent plastic hinge length based on 'equivalent plastic hinge length method'. Considering the balance of strength and deformation conditions, suitable analysis values were derived from 'split Element Method'. Through various parametric studies, various factors affecting the residual strain were decided. Based on the results of this study, it is expected many researches will be proceed in the future.

New Equivalent Circuit Model for Interpreting Spectral Induced Polarization Anomalous Data (광대역유도분극 이상 자료의 해석을 위한 새로운 등가회로 모델)

  • Shin, Seungwook;Park, Samgyu;Shin, Dongbok
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.4
    • /
    • pp.242-246
    • /
    • 2014
  • Spectral induced polarization (SIP) is a useful technique, which uses electrochemical properties, for exploration of metallic sulfide minerals. Equivalent circuit analysis is commonly conducted to calculate IP parameters from SIP data. An equivalent circuit model, which indicates the SIP response of rock, has a non-uniqueness problem. For this reason, it is very important to select the proper model for accurate analysis. Thus, this study focused on suggesting a new model, which suitable for the analysis of an anomalous SIP response, such as ore. A suitability of the new model was verified by comparing it with the existing Dias model and Cole-Cole models. Analysis errors were represented as a normalized root mean square error (NRMSE). The analysis result using the Dias model was the NRMSE of 10.50% and was the NRMSE using the Cole-Cole model of 17.03%. Howerver, because the NRMSE of the new model is 0.87%, it is considered that the new model is more useful for analyzing the anomalous SIP data than other models.

Numerical Modelling of Vertical Drains Installed in Soft Deposit under Embankment (성토재 아래의 연약지반에 설치된 연직배수재의 수치모델링)

  • 이승래;김윤태
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.127-138
    • /
    • 1996
  • The in-situ consolidation behavior of drainage system-installed deposits has three dimensional characteristics. Therefore, for an approximate 2-D plane strain consolidation analysis, it is necessary to convert the 3-D spatial flow of actual cases into the laminar flow simulated by the 2-D plane strain model. . In this paper, in order to properly model the effect of three dimensional characteristics, an equivalent and efficient model has been applied in a finite element technique for the analysis of the drainage system-installed soil deposits. The equivalent two dimensional model involves equivalent permeabilities and drainage widths. To validate the equivalent two dimensional model, three dimensional analyses were per formed by using the ABAQUS program and the results of 3-D analyses were compared with those of the 2-D analyses. By using the proposed equivalent model, one may be able to appropriately predict the consolidation behavior of drainage system-installed soft deposits.

  • PDF

Estimation of Equivalent Diameter for Cross Shaped Vertical Drain Installed in Weak Clay Soils (연약점성토 지반에 타설된 십자형배수재의 등가직경 산정)

  • 장연수;김영우;김수삼
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • In this paper, the consolidation efficiency and the equivalent diameter of the cross shaped drain are examined by using the laboratory test and the numerical model, and the results are compared with those of the band shaped drain. The equivalent diameter of the tested drains is back-calculated from the laboratory experiment and compared with those calculated from the formula suggested in the literature. The efficiency of the cross shaped drain is evaluated by using the 3-D flow program which was validated by the settlement-time test fill data. The results of laboratory test show that the equivalent diameter of the band shaped drain was close to the Rixner's formula and that of the cross shaped drain was fit to the following formula: $d_w\;=\; \\tarc{3}{4}.(b+t)$The results of the numerical analysis show that the cross shaped drain can reduce the consolidation time by 9-10% from that for the band shaped drain. The equivalent diameter obtained from the numerical flow model by using the field data is 3.5 times smaller than that obtained from the laboratory consolidation test.

  • PDF

A Equivalent Circuit for Lossless 2-Port Using Inverter and Its Application (무 손실 2-포트 회로의 인버터를 사용한 등가회로 및 응용)

  • Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.761-770
    • /
    • 2008
  • Impedance or admittance inverter is a conceptual 2-port device frequently used in microwave filter design. In this paper, the equivalent circuit using inverter for general loss less 2-port circuit is presented. Our equivalent circuit can be directly and easily represented with z- or y-parameters compared with the conventional methods. Based on the representation, the derived results for various coupled lines such as parallel coupled line and anti-parallel coupled lines are compared ours. In addition, the results of other workers for improvement of the distortion in frequency response of microstrip coupled line filter are derived using our representation and compared. The proposed equivalent circuit shows the difference with conventional equivalent circuit so the conventional design method can not be applied to parallel coupled line filter with our representation. So in this paper the novel design method is proposed and we showed the method yields more accurate design results.

Derivation of Single Phase Material Properties Equivalent to 1-3 Piezoelectric Composites by the Resonant Method (공진법을 이용한 1-3형 압전복합체의 단일상 등가물성 도출)

  • Kim, Jin-Wook;Pyo, Sung-Hun;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.7
    • /
    • pp.368-376
    • /
    • 2011
  • Piezoelectric composites have been widely used in broadband acoustic transducers because of their lower acoustic impedance and higher electro-mechanical coupling factor. However, their complex structure has placed many limitations on the design of various transducers. This paper suggests the methodology to substitute the 1-3 piezocomposites by a single-phased material that has properties equivalent to those of the piezocomposites. The resonant method and finite element analysis (FEA) are used to derive the equivalent properties that can accurately depict resonant properties at various vibration modes of the piezocomposites. Validity of the suggested method is confirmed by comparing frequency characteristics of fabricated 1-3 piezocomposite specimens and FEA models. Further, accuracy of the derived material constants is checked by applying the equivalent properties to FEA models of the single phase material for various resonant modes.

Calculation of the TNT Equivalent Mass of the Possible Explosion of CO, CH4, and C2H4 (CO와 CH4, C2H4 혼합 가스 폭발에 대한 TNT 등가량 계산)

  • Kim, Minju;Kwon, Sangki
    • Explosives and Blasting
    • /
    • v.38 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • Gas explosion accidents are steadily being issued due to increased gas consumption in Korea and foreign countries. To analyze the effects of these gas explosions, a TNT equivalent method is used. In this study, the TNT equivalent was calculated in the event of an explosion due to the volume content in the air of CO, CH4 and C2H4, the typical flammable gases emitted by coal. Also, the peak overpressure and impulse variation with the distance from explosion point were compared and analyzed by gas using the calculated equivalent value of TNT. The upper limit of the TNT equivalent for the three mixed gases is up to five times larger than the other gases mixture. In addition, the peak overpressure and impulse, which are factors of the TNT characteristic curve, are also increasing as the number of gases increases.

Evaluation of Capacity Spectrum Methods for Estimating the Peak Inelastic Responses (최대 비탄성 변위 응답 예측을 위한 기존 능력스펙트럼법들의 유효성 평가 및 비교)

  • 김홍진;민경원;이상현;박민규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.35-44
    • /
    • 2004
  • In the capacity spectrum method(CSM) using a linear response spectrum, the peak response of an inelastic system under a given earthquake load is estimated transforming the system into the equivalent elastic one. The CSM for estimating the peak inelastic response is evaluated in this paper. The equivalent period and damping ratio are calculated using the ATC-40, G lkan, Kowalsky, and Iwan methods, and the performance points are obtained according to the procedure B of ATC-40. Analysis results indicate that the ATC-40 method generally underestimates the peak response resulting in the unsafe design, while the G lkan and Kowalsky methods overestimate the responses. The Iwan method produces the values between those by the ATC-40 method and the G lkan and Kowalsky methods, and estimates the responses relatively closer to the exact ones. Further, it is found that the Kowalsky method gives the negative equivalent damping ratios depending on the hardening ratios, and thereby can not be used to estimate the responses in some cases.

Analysis of the Mean and Standard Deviation due to the Change of the Probability Density Function on Tidal Elevation Data (조위의 확률밀도함수 변화에 따른 평균 및 표준편차 분석)

  • Cho, Hong-Yeon;Jeong, Shin-Taek;Lee, Khil-Ha;Kim, Tae-Heon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.4
    • /
    • pp.279-285
    • /
    • 2010
  • In the process of the probabilistic-based design on the coastal structures, the probability density function (pdf) of tidal elevation data is assumed as the normal distribution function. The pdf shape of tidal elevation data, however, is better-fitted to the double-peak normal distribution function and the equivalent mean and standard deviation (SD) estimation process based on the equivalent normal distribution is required. The equivalent mean and SD (equivalent parameters) are different with the mean and SD (normal parameters) estimated in the condition that the pdf of tidal elevation is normal distribution. In this study, the difference, i.e., estimation error, between equivalent parameters and normal parameters is compared and analysed. The difference is increased as the tidal elevation and its range are increased. The mean and SD differences in the condition of the tidal elevation is ${\pm}400cm$ are above 100 cm and about 80~100 cm, respectively, in Incheon station. Whereas, the mean and SD differences in the condition of the tidal elevation is ${\pm}60cm$ are very small values in the range of 2~4 cm, in Pohang station.

Evaluation of Seismic Performance of Mixed Building Structures by using the Nonlinear Displacement Mode Method (비선형 변위모드법을 적용한 복합구조물의 내진성능평가)

  • 김부식;송호산
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.71-80
    • /
    • 2003
  • Though a nonlinear time history analysis may be provided to estimate more exactly the seismic performance of building structure, approximation methods are still needed in the aspect of practicality and simplicity, In converting a multi-story structure to an equivalent SDOF system, the mode vectors of the multi-story structure are assumed as the mode shape in elastic state regardless of elastic or elastic-plastic state. However, the characteristics of displacement mode are also changed after the yielding made in the structural elements, because the structure becomes inelastic in each incremental load step. In this research, a method of converting MDOF system to ESDOF system is presented by using nonlinear displacement mode considering the mode change of structures after the yielding. Also, the accuracy and efficiency of the method of the nonlinear displacement mode method of the estimate of seismic response of Mixed Building Structures were examined by comparing the displacements of the roof level of the multi-story building structures estimated from this converted displacement response of ESDOF with the displacement of the roof level through the nonlinear dynamic analysis of the multi-story building structures subjected to an actual earthquake excitation.