• Title/Summary/Keyword: 등가렌즈

Search Result 36, Processing Time 0.022 seconds

Corneal Asphericity for Myopia in Korea (한국인 근시안의 각막 비구면성)

  • Kim, Hyo-Jin;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.109-114
    • /
    • 2006
  • We evaluated the contour using corneal asphericity of the myopic cornea in Korea and investigated the relationship between refractive error and other ocular dimensions in Korean myopia, including anterior chamber depth and asphericity. The monoocular asphericity value of 50 myopes with $-4.83{\pm}2.38$ D between early 20 age and early 30 age in adult was included. Cycloplegic refraction, corneal asphericity and anterior chamber depth using corneal topography were examined. The mean asphericity values were$-0.27{\pm}0.13$ and the corneas of 96.0% were prolate ellipse. Refractive error was related to asphericity and anterior chamber depth among myopes. However, asphericity only were significant difference in high and low myopia group. Corneal configuration on the contact lens fits are discussed. We think that the longitudinal study for myopia and asphericity was required.

  • PDF

Area storage density of ideal 3-D holographic disk memories (이상적인 디스크형 3차원 홀로그래픽 메모리에서의 면적 저장밀도)

  • 장주석;신동학
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.1
    • /
    • pp.58-64
    • /
    • 2000
  • Assuming that the performance of holographic storage media is ideal, we estimate the area storage density of disk-type holographic memories, when the method of either angle multiplexing, or rotational multiplexing, or both are used. The area storage density is strongly dependent on the f numbers (ratio of focal length to diameter) of both the Fourier transform lens in the signal arm, denoted by $F/#_2$, and the angle range over which the reference beam is incident (or, the equivalent f number corresponding to the angle range denoted by $F/#_1$). The area storage density is largely independent of the pixel pitch of the spatial light modulator when the Fourier plane holograms are recorded, while it is sensitive to the pixel pitch when the image plane holograms are recorded. In general, to obtain high area storage density, the Fourier or at least near Fourier plane holograms rather than the image plane holograms should be recorded. In addition, when the thickness of the recording materials are less than approximately $500\mu\extrm{m}$, rotational multiplexing gives higher area storage densities than angle multiplexing does. To increase the storage density further, however, it is desirable to use both of the two multiplexing methods in combination.nation.

  • PDF

Dose Distribution of 100 MeV Proton Beams in KOMAC by using Liquid Organic Scintillator (액체 섬광체를 이용한 100 MeV 양성자 빔의 선량 분포 평가)

  • Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.621-626
    • /
    • 2017
  • In this paper, an optical dosimetric system for radiation dose measurement is developed and characterized for 100 MeV proton beams in KOMAC(Korea Multi-Purpose Accelerator Complex). The system consists of 10 wt% Ultima GoldTM liquid organic scintillator in the ethanol, a camera lens(50 mm / f1.8), and a high sensitivity CMOS(complementary metal-oxide-semiconductor) camera (ASI120MM, ZWO Co.). The FOV(field of view) of the system is designed to be 150 mm at a distance of 2 m. This system showed sufficient linearity in the range of 1~40 Gy for the 100 MeV proton beams in KOMAC. We also successfully got the percentage depth dose and the isodose curves of the 100 MeV proton beams from the captured images. Because the solvent is not a human tissue equivalent material, we can not directly measure the absorbed dose of the human body. Through this study, we have established the optical dosimetric procedure and propose a new volume dose assessment method.

A Study for the Refractive Error in Middle and High School Pupils on the Basis of Their Glasses Power (안경도수를 근거로 한 중·고등학생의 굴절이상에 관한 연구)

  • Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.169-175
    • /
    • 2003
  • This research reviewed that 83 male subjects. 89 female subjects of middle and high school visited D Optical shop at the downtown of Daegu more than twice from January, 1999 to January, 2003 and obtained the following results by using the visual acuity prescription of them for which D Optical shop was keeping. 1. The classification of correction power for 190 myopia eyes was examined (87 male eyes, 103 female eyes) showed 89 eyes(46.82%) between $0.25D{\leq}3.00D$, 86 eyes(45.26%) between $3.25D{\leq}6.00D$, 15 eyes(7.89%) for over 6.25D. 2. The kind of 154 astigmatism subjects(79 male eyes, 75 female eyes) was direct astigmatism 83.77%, reverse astigmatism 11.69%, oblique astigmatism 4.55%. The cylindrical correction power for astigmatic eyes was 61 eyes(39.61%) between $0.25D{\leq}0.50D$, 60 eyes(38.96%) between 0.50D<1.00D, 121 eyes(78.57%) for less than 1.06D, 6 eyes(0.65%) for over 3.00D. 3. The variation of spherical power showed 161 eyes(46.80%) between $0.00D{\leq}0.50D$, 109 eyes(31.69%) between $0.51D{\leq}1.00D$, 17 eyes(4.94%) for over 2.01D variation. 4. The variation of astigmatic power showed 92 eyes(59.74%) between $0.00D{\leq}0.50D$, 39 eyes(25.32%) between $0.26D{\leq}0.50D$, 10eyes (6.49%) between $0.51D{\leq}0.75D$, 13 eyes(8.44 %) for over 0.76D astigmatic variation. 5. The variation of equivalent spherical power showed 137 eyes(39.83%) between $0.00D{\leq}0.50D$, 126 eyes(36.63%) between $0.51D{\leq}1.00D$, 40 eyes(11.63%) between $1.01D{\leq}1.50D$, 21 eyes(6.10%) between $1.51D{\leq}2.00D$, 20 eyes(5.81%) for over 2.01D variation.

  • PDF

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.