• Title/Summary/Keyword: 두 화염

Search Result 88, Processing Time 0.023 seconds

Numerical Analysis on the Reacting Flow-Field of Coaxial Combustor with a Wedge-Shaped Flame Holder (Wedge형 보염기를 장착한 동축형 연소기의 반응 유동장 수치해석)

  • Ko Hyun;Sung Hong-Gye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.450-454
    • /
    • 2005
  • A numerical analysis is performed to analyze the reacting flow-field of an axisymetric coaxial ramjet combustor. Two dimensional Navier-Stokes equation with low Reynolds number $k-\varepsilon$ turbulence model is utilized and finite-rate chemistry model is adopted. Eddy dissipation model is applied for a modeling of turbulent combustion. Two different types of combustors (combustor with a suddenly expanded dump and combustor with wedge-shaped flame holders) are compared in a view point of flame stabilizing.

  • PDF

Development of Early Tunnel Fire Detection algorithm Using the Image Processing (영상 처리 기법을 이용한 터널 내 화재의 조기 탐지 기법의 개발)

  • Lee, Byoung-Moo;Han, Don-Gil
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10b
    • /
    • pp.499-504
    • /
    • 2006
  • 터널 내 화재 발생 시 대규모의 인명, 재산 피해가 발생하는데 이러한 상황을 조기에 탐지함으로써 피해를 최소화하기 위한 시스템이 필요하다. 또한 터널 내 설치된 CCTV를 사람이 24시간 감시하기에는 너무 어려운 점이 많다. 이에 따라 적절한 영상 처리를 통한 화염 및 연기 검출 시스템을 통해 경보를 알려줄 경우, 보다 편리하고 사람이 모니터 앞에 없을 때 화재 발생 시 화재를 검출할 수 있어 피해를 최소화 할 수 있다. 본 논문에서는 영상처리 기법을 이용하여 터널 안에서 발생한 화재 및 연기를 고속으로 탐지하기 위한 알고리즘을 제안하였다. 터널 안에서의 화재 탐지는 차량 조명 및 터널내의 조명등과 같은 여러 가지 상황에 의해 산불 탐지 알고리즘과 다른 독자적인 알고리즘의 개발이 요구된다. 본 논문에서 제시한 두 가지 알고리즘은 기존 알고리즘보다 정확한 위치 탐지와 초기 단계에서의 탐지가 가능하도록 되었다. 또한 우리는 실험 결과를 통해 각각의 성능을 비교함으로써 제시한 알고리즘의 타당성을 보여주었다.

  • PDF

Development of System on the Sustained Production of Chlorine Dioxide Using Polymer Hydrogels (고분자 수화젤을 이용한 이산화염소의 지속적 생성 시스템의 개발)

  • Jeon, Younghyun;Kim, Bumsang
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.173-176
    • /
    • 2012
  • Chlorine dioxide has an excellent ability to sterilize and deodorize and is harmless to humans. However, it is very unstable and explosive as it is highly concentrated, thus its use in the air clean filed has been limited. Therefore, there is a demand to develop the system to produce a low concentration of chlorine dioxide sustainedly. Here, for a first step in the development of the system on the sustained production of chlorine dioxide, the use of polymer hydrogels was investigated. P(MMA-co-HEMA) hydrogel particles were prepared via dispersion photopolymerization and sodium chlorite and citric acid were loaded respectively in the hydrogel particles. When sodium chlorite and citric acid were reacted with not loaded in the hydrogels, rapid production of chlorine dioxide occurred and the concentration of chlorine dioxide decreased over time. However, when sodium chlorite and citric acid were loaded respectively in the hydrogel particles and reacted, chlorine dioxide was produced slowly and sustainedly because the release of sodium chlorite and citric acid from the hydrogels delayed the reaction between them. The result shows that the use of P(MMA-co HEMA) hydrogels has the potential to develop the system on the sustained production of chlorine dioxide.

A Numerical Study on the Effects of Meteorological Conditions on Building Fires Using GIS and a CFD Model (GIS와 전산유체역학 모델을 이용한 기상 조건이 건물 화재에 미치는 영향 연구)

  • Mun, Da-Som;Kim, Min-Ji;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.395-408
    • /
    • 2021
  • In this study, we investigated the effects of wind speed and direction on building fires using GIS and a CFD model. We conducted numerical simulations for a fire event that occurred at an apartment in Ulsan on October 8, 2020. For realistic simulations, we used the profiles of wind speeds and directions and temperatures predicted by the local data assimilation and prediction system (LDAPS). First, using the realistic boundary conditions, we conducted two numerical simulations (a control run, CNTL, considered the building fire and the other assumed the same conditions as CNTL except for the building fire). Then, we conducted the additional four simulations with the same conditions as CNTL except for the inflow wind speeds and direction. When the ignition point was located on the windward of the building, strong updraft induced by the fire had a wide impact on the building roof and downwind region. The evacuation floor (15th floor) played a role to spread fire to the downwind wall of the building. The weaker the wind speed, the narrower fire spread around the ignition point, but the higher the flame above the building reaches. When the ignition point was located on the downwind wall of the building, the flame didn't spread to the upwind wall of the building. The results showed that wind speed and direction were important for the flow and temperature (or flame) distribution around a firing building.

Establishment of Fire Reliability Assessment Method for Structural Strength (화재시 구조강도에 대한 신뢰성 평가방법의 정립)

  • Park, Chang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.54-62
    • /
    • 2017
  • This paper describes the behavior and failure probability of the basic structural members in a fire for the fire safety assessment of offshore structures. A fire safety assessment can be accomplished by comparing the fire resistance of the members with the fire severity of the heat load due to fire. The fire severity is represented as the maximum temperature of the members using the Eurocode 1 standard fire curve and heat transfer equation. On the other hand, the fire resistance is the limiting temperature calculated by a simplified formula in the case of simple structural members. Considering the complexity of FPSOs and offshore structures, a general-purpose structural analysis program should be used and the limiting temperature obtained by analyzing the structural strength of the members through an elasto-plastic analysis with a large deflection, and compared with the maximum temperature. Also, the equality of these two methods of evaluating the fire resistance was confirmed by comparing them. Following three criteria, the strength, serviceability and stability, three failure modes, namely the first failure of a hinge, large deflection and buckling, were chosen. The failure temperature was verified for each failure mode. using the AFOSM method in the equation of the fire severity and fire resistance, thereby giving the failure probability of the member. By applying these processes to the example of a beam and plate, the behavior of the structure and failure (temperature?) of each failure mode can be determined.

Effect of Swirl Cup Geometry on Spray Characteristics in Gas Turbine Engine (가스터빈 연소기의 스월컵 형상이 분무특성에 미치는 영향)

  • 김동준;박종훈;고현석;윤영빈
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.29-36
    • /
    • 2002
  • Experiments have been performed to investigate the effect of secondary venturi tip angle on flow and spray characteristics in gas turbine combustor with a swirl cup assembly. Three variations of secondary venturi tip angle are made: converging, straight and diverging angles. It is found that the variation of venturi tip angle results in the significant changes of flow and spray characteristics in gas turbine combustors, such as the size and location of recirculation zones. drop size and mass distribution affecting combustion efficiency and NOx emissions. In diverge case, central toroidal recirculation zone(CTRZ) exists near the exit, which is known to be beneficial for flame stability. But in converge case, the finest SMD distribution and uniform mass distribution are found and CTRZ is longer than other cases. Consequently, high combustion efficiency and low pollutant emission are expected in converge case.

Coupling Behavior of Pressure and Heat Release Oscillations by Swirl Injection in Hybrid Rocket (스월에 의한 하이브리드 로켓의 연소압력과 연소반응 진동의 결합 거동)

  • Kim, Jungeun;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.567-574
    • /
    • 2018
  • Swirl injection induces not only the increase in fuel regression rate but also the reduction of combustion pressure oscillation. This acts, in turn, to stabilize combustion process. Thus, this study primarily focuses on the change in flow structure in the main chamber by swirl injection. Then examining the change in flow structure was done to understand the physical process for stabilizing combustion. In the results, the application of swirl injection could suppress the generation of p' and q' in 500Hz band and could shift the phase difference and cross correlation. Further investigations with combustion visualization also show that the development of helical motion near surface region affects the small-sized vortex generation and shedding yielding combustion stabilization eventually.

A Study on Tar Removal in Syngas Produced from Woodchip Gasification Using Oxidation Catalyst and Utilization of Syngas by Co-combustion (산화촉매를 이용한 우드칩 가스화 합성가스 내 타르 제거 및 합성가스 혼합연소 이용기술 연구)

  • Yoon, SangJun;Kim, YongKu;Lee, JaeGoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.175.1-175.1
    • /
    • 2011
  • 우드칩을 포함하는 화석연료대비 발열량이 낮은 바이오매스를 가스화를 통하여 활용하는 경우 타르 및 수트를 포함하는 저열량의 합성가스가 생성된다. 이러한 합성가스를 엔진을 통한 발전, 스팀, 수소 및 화학제품 생산으로 활용하기 위해서는 고효율의 타르 정제 및 제거가 필수적이다. 특히 착화가 어렵고 연소온도 및 연소율이 낮으며, 화염구간이 좁은 저열량의 합성가스를 이용하여 스팀을 생산하기 위해서는 많은 문제점으로 인하여 기술 개발이 필요하다. 본 연구에서는 하향류식 가스화기를 이용하여 우드칩을 연료로 합성가스를 제조하였으며, 합성가스에 포함되어 있는 타르 및 수트와 같은 미반응 물질을 제거할 수 있는 집진, 세정장치를 설계 및 제작하였다. 특히 고효율 타르의 제거를 위하여 두 종류의 산화촉매를 이용한 합성가스 내 타르의 제거 연구를 수행하였다. Ru 촉매를 이용하는 경우 합성가스 내 타르의 농도를 100ppb 정도까지 저감이 가능하였다. 정제된 합성가스는 유류 혼소 버너를 통하여 보일러 연소실에서 혼합연소되어 30만kcal/h의 열을 공급함으로써 스팀을 생산 하였으며, 생성된 스팀은 블록 건조 시설에서 이용하였다.

  • PDF

The Effect of Wall Condition on the Methane-air Premixed Flame Propagation between Narrow Two Walls (좁은 간격의 두 벽면 사이에서의 메탄-공기 예혼합 화염 전파에 벽면 상태가 미치는 영향)

  • Choi, Won-Young;Kwon, Hyuck-Mo;Lee, Dae-Hoon;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.37-41
    • /
    • 2004
  • Quenching phenomena is one of major concern in development of millimeter or sub-millimeter scale micro combustor for the size of the combustor is near extinction condition. In this work we focused on the effect of combustor wall condition that was parameterized by Perovskite LSC($La_{0.8}$$Sr_{0.2}$$CoO_3$) redox catalyst. The experiment was done by variable gap-width 2D wall equipment. The flame was produced by premixed methane-air jet issuing from millimeter-scale slot burner and it propagated through the narrow gap of the walls. By comparison of flame behaviour near catalyst-coated wall and simple glass wall, we investigated the effect of possible surface reaction on quenching phenomena. The flame between two plates was observed where the gap of the plates was reduced stepwise from 20mm to a distance of quenching occurrence. The two flames with and without surface modification were almost same by observation. But the gap for the occurrence of quenching was increased between catalyst-coated wall. So we concluded that surface reaction close to combustor wall has a negative effect on micro combustion.

  • PDF

The Premixed Flame in a Radiatively Active Porous Medium (복사열전달을 동반하는 다공성 매질내의 예혼합 화염)

  • 김정수;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.265-270
    • /
    • 1989
  • The present study considers the thermal structure variation in a porous medium caused by changing the most important radiative property of porous medium, absorption coefficient, as well as altering the physical dimension of porous medium and the equivalence ratio of premixed gas mixture. The radiation model was introduced as an unsteady differential form using the two-flux gray radiation model. The role of the conductive heat transfer through both gas phase and porous medium was found to be almost insignificant compared with that of the radiative heat transfer. The reaction zone shifted upstream and the flame thickness decreased as either the geometrical length of porous medium increased or the absorption coefficient decreased.