• Title/Summary/Keyword: 두께 소음

Search Result 391, Processing Time 0.022 seconds

Assessment and Verification of Prediction Model(NIER('99)) for Road Traffic Noise in the Apartment Complex (아파트단지에서 국립환경과학원 도로교통소음 예측식('99)에 대한 통계학적 평가 및 검증)

  • Cho, Il-Hyoung;SunWoo, Young;Lee, Nae-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1198-1206
    • /
    • 2006
  • We have carried out highway traffic noise prediction and measurement for 10 sites with representative road shapes and structures. A road traffic noise prediction model(NIER('99)) has been developed for environmental impact assessment in Korea. With the fitted regression analysis, the distribution ratio($R^2$) and Pearson correction coefficient(r) was 92.4% and 0.96 in $1^{st}$ floor, 38.7% and 0.66 in $3^{rd}$ floor, 42% and 0.65 in $5^{th}$ floor, 7.5% and 0.27 in $7^{th}$ floor, 28.4% and 0.53 in 10th floor, 35.6% and 0.60 in $13^{th}$ floor, 52.7% and 0.73 in $15^{th}$ floor, respectively. The measured values of the noise level except the 1st floor did not show a good agreement with the predicted noise level in the NIER('99) formula. Also, the NIER('99) formula demonstrated that the measured values weren't reasonably close to the predicted values, indicating the validity and adequacy of the predicted models with the fitted vs residual analysis in the 95% of confidence interval and 95% of predict interval. Using the equal variation on the basis of the residual vs fitted value, there was the significant difference for variation between $3^{rd}$ floor and $15^{th}$ floor except $1^{st}$ floor. The results suggested that the NIER('99) model obtained by the results according to the apartment floor must be improved and developed on the road traffic noise.

A Comparison Study on the Design of Dynamic Response appears on Bridge as operation of Light Railway Train (한국형 경량 전철 주행시 동적 응답 처리의 설계 기준 비교 연구)

  • Yeon, sang-ho;Kang, sung-won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.792-795
    • /
    • 2008
  • AGT system is a kind of light railway train. AGT system use of concrete track and rubber tire, so it can be reduce the noise and vibration, compare to the normal train system. And, the dynamic responses of normal bridge are influenced by the dynamic characteristics of bridge, the speed of vehicle and the surface roughness of railway. But the AGT system bridge is influenced not only the above facts but also the guiderail unevenness, because, AGT vehicle steered by guiderail. So, in this study, optimized service condition is suggested for the design and operation of AGT system, by the means of experimental study. The experiments are executed for PSC bridge with length of 30m, at the AGT test line in Kyongsan. The test results are compared and investigated according to the prominence. In the test result, the guiderail prominence influenced on the dynamic response of bridge. It shows a increase as compared with no guiderail prominence in the dynamic response value acceleration, displacement, stain.

  • PDF

The survey on the patterns of school facilities usages for studying a space improvement plan of elementary school on narrow sites - Focused on elementary schools in Seoul - (부지 협소 초등학교의 공간 조성 방안 연구를 위한 학교 시설 이용 실태 조사 - 서울특별시 소재 초등학교를 중심으로 -)

  • Kim, Sae-Rom;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2019
  • In this study, interviews are held with the faculties of two elementary schools on narrow sites located in Seoul to examine the existing problems of the elementary school on narrow site and the need for the new facilities of the elementary school on narrow site in order to derive the implications for the planning guidelines of such school construction. As a result of the survey, it was found that the substitutes of the playground installed in the elementary school on narrow site were not suitable for physical play activities, physical education class activities, and other curriculum operations. In order to secure an adequate physical activity an space for elementary schools, faculty members were demanding that the entire floor or rooftop of the school building be spatialized for physical activities. Additionally, problems such as noise generation and the lack of special rooms and public space were occurring in the elementary schools on narrow sites and are being deteriorated by accommodating an over number of students, and therefore policies are required to ensure that the appropriate number of students are maintained in the case of the schools on narrow sites.

Development of Preliminary Conceptual Design/ Comprehensive Analysis Programs for Next Generation Rotorcraft (차세대 회전익 기본개념설계/통합해석 프로그램의 개발)

  • Oh, Sejong;Park, Donghoon;Ji, Hyung Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.1
    • /
    • pp.75-84
    • /
    • 2021
  • The authors had presented two previous papers[1,2] on Helicopter/Rotorcraft develoment in Europe and US. Meanwhile, the next generation rotorcrafts, currently under development in US and Europe, have new configurations (tilt-rotor, coaxial, compound) of rotor-type vertical takeoff/landing rotorcrafts to overcome the disadvantages of traditional helicopters. For developing these new types of rotorcrafts, the upgraded conceptual design/comprehensive programs are required. In US and Europe, they are already developing new program tools with their technologies and database obtained during more than last half centuries. For us, many academia, research institutes and industrial engineers have experienced and developed core technologies on rotorcrafts (aerodynamics, structural analysis, flight dynamics, and noise analysis etc.) comparable to US and Europe during last couple of decades of developing helicopters and various configurations of rotorcrafts. In this paper, the pros and cons of conceptual design/comprehensive tools currently used in US and Europe have been summarized. Furthermore, the possibilities and problems to develope our own design and analysis tools have been studied.

A Study on Determination of the Minimum Vertical Spring Stiffness of Track Pads Considering Running Safety (열차주행안전을 고려한 궤도패드의 최소 수직 스프링계수 결정에 관한 연구)

  • Kim, Jeong-il;Yang, Sin-Chu;Kim, Yun-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2D
    • /
    • pp.299-309
    • /
    • 2006
  • Railway noise and vibration has been recognized as major problems with the speed-up of rolling stock. As a kind of solution to these problems, the decrease of stiffness of track pad have been tried. However, in this case, overturning of rail due to lateral force should be considered because it can have effect on the safety of running train. Therefore, above two things - decrease of stiffness of track pad and overturning of rail due to lateral force - should be considered simultaneously for the appropriate determination of spring coefficient of track pad. With this viewpoint, minimum spring coefficient of track pad is estimated through the comparison between the theoretical relationship about the overturning of rail and 3-dimensional FE analysis result. Two kinds of Lateral force and wheel load are used as input loads. Extracted values from the conventional estimation formula and the Shinkansen design loads are used. It is found that the overturning of rail changes corresponding to the change of the stiffness of track pad and the ratio of lateral force to wheel load. Moreover, it is found that the analysis model can have influence on the results. Through these procedure, minimum spring coefficient of track pad is estimated.

Related factors on musculoskeletal symptoms in selected Korean female office and blue-collar workers (우리나라 일부 사무직과 생산직 여성근로자에서 근골격계 자각증상과 관련요인)

  • Lee, Kyung-Jae;Han, Sung-Hyun;Ahn, Yeon-Soon;Hwang, Jung-Ho;Kim, Joo-Ja
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.4
    • /
    • pp.289-299
    • /
    • 2007
  • Objectives : To investigate the related factors on musculoskeletal symptoms among Korean female workers. Methods : A total of 1,875 female workers (1,002 office workers and 873 blue-collar workers) was analyzed. They were randomly selected among female workers by cluster sampling and interviewed by well trained interviewer, who filled out a structured questionnaire on the musculoskeletal symptoms. Other factors such as general and occupational characteristics including workplace location, employment condition, work duration, and working condition were also investigated. Results : Current smokers and drinkers were significantly more common in blue-collar workers than in office workers. Those working full time were significantly more common in blue-collar workers than in office workers. Those working over 8 hours per day were also popular in office workers than in blue-collar workers. Subjective musculoskeletal symptoms were significantly higher in the type of work including excessive repetitive work, work using awkward stretching hand upwards, work using repetitive wrist movements, static work using awkward hand posture, and heavy manual lifting and handling works. The mean score of the symptoms were significantly higher in blue-collar than in office workers. The significantly different working factors between two groups were work duration, employment condition and daily work hours. Conclusion : We suggest that the type of work including awkward and repetitive works as well as job type may be one of the most important factors related to musculoskeletal symptoms of female workers in the workplace. Preventive strategy will be needed to prevent the negative impact on health status of working women in the workplace.

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Proposal for Amendment of the Basic Environmental Policy Act ('BEPA') Article 31 (환경정책기본법 제31조 무과실책임규정의 개정방안)

  • Koh, Moon-Hyun
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.125-147
    • /
    • 2009
  • The Basic Environmental Policy Act (BEPA) (Law No. 4257 effective 1. August 1990) sets forth the basic policies and administrative framework for environmental preservation, leaving more detailed regulations, and emission controls to separate laws targeting air, water, and solid waste, etc. The BEPA Article 31 adopts an unprecedented strict liability standard for damages as an absolute liability. The BEPA Article 31 provides for liability as follows. If a company is alleged to have caused damage through pollution of the environment, it will be liable for damages unless it can show that the pollution did not cause damages, or that it did not actually cause pollution. If the company did cause pollution, and if the pollution is the cause for the damages in question, the company will be liable irrespective of whether it was negligent or otherwise at fault. If there are two or more companies involved in the pollution, but it is unclear which company caused the damages, all of the companies will be jointly and severally liable for the damages. In this paper, the author attempts to uncover the problems of BEPA Article 31 and then seeks desirable amendments by comparing it to the German Environmental Liability Act. First, it will be necessary to provide definitions of 'companies etc.'. Second, it will be necessary to enumerate the kinds of company facilities. Third, it will be necessary to provide exclusionary clauses on material damages. Fourth, it will be necessary to show 'presumption of cause and effect'. Fifth, it will be necessary to provide a clause on 'right to information'. Sixth, it will be necessary to provide a clause for force majeure. Seventh, it will be necessary to take measures to secure abundant liability for damages which can be caused by the owner of the facility, the potential polluter. Finally, it is appropriate that Korea now legislate an Environmental Liability Act akin to the German Environmental Liability Act.

  • PDF

Effects of vocal aerobic treatment on voice improvement in patients with voice disorders (성대에어로빅치료법이 음성장애환자의 음성개선에 미치는 효과)

  • Park, Jun-Hee;Yoo, Jae-Yeon;Lee, Ha-Na
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.69-76
    • /
    • 2019
  • This study aimed to investigate the effects of vocal aerobic treatment (VAT) on the improvement of voice in patients with voice disorders. Twenty patients (13 males, 7 females) were diagnosed with voice disorders on the basis of videostroboscopy and voice evaluations. Acoustic evaluation was performed with the Multidimensional voice program (MDVP) and Voice Range Profile (VRP) of Computerized Speech Lab (CSL), and aerodynamic evaluation with PAS (Phonatory Aerodynamic System). The changes in F0, Jitter, Shimmer, and NHR before and after treatment were measured by MDVP. F0 range and Energy range were measured with VRP before and after treatment, and the changes in Expiratory Volume (FVC), Phonation Time (PHOT), Mean Expiratory Airflow (MEAF), Mean Peak Air Pressure (MPAP), and Aerodynamic Efficiency (AEFF) with PAS. Videostroboscopy was performed to evaluate the regularity, symmetry, mucosal wave, and amplitude changes of both vocal cords before and after treatment. Voice therapy was performed once a week for each patient using the VAT program in a holistic voice therapy approach. The average number of treatments per patient was 6.5. In the MDVP, Jitter, Shimmer, and NHR showed statistically significant decreases (p < .001, p < .01, p < .05). VRP results showed that Hz and semitones in the frequency range improved significantly after treatment (p < .01, p < .05), as did PAS, FVC, and PHOT (p < .01, p < .001). The results for videostroboscopy, functional voice disorder, laryngopharyngeal reflux, and benign vocal fold lesions were normal. Thus, the VAT program was found to be effective in improving the acoustic and aerodynamic aspects of the voice of patients with voice disorders. In future studies, the effect of VAT on the same group of voice disorders should be studied. It is also necessary to investigate subjective voice improvement and objective voice improvement. Furthermore, it is necessary to examine the effects of VAT in professional voice users.