• Title/Summary/Keyword: 두께감소율

Search Result 581, Processing Time 0.028 seconds

Effects of Film Thickness and Moisture Absorbing material on Ginger Quality during MA Storage (필름두께 및 흡습제 처리에 따른 생강의 MA 저장효과)

  • 정문철;남궁배;김동만
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.264-269
    • /
    • 1999
  • The effects of film thickness and moisture absorbing materials(MAM) on the ginger qualities were investigated during MA storage for 150 days. LDPE films of 0.04, 0.06 and 0.08mm thicknesses were applied to select the adequate film in gas permiability. MAMs of sheet and sachet type were applied to 0.06mm-LDPE film bag to prevent moisture condensation during storage. Thickness of film used affected neither weight loss nor firmness of gingers during U storage. But the thinner in thickness showed the less changes in sprouting, spoilage and reducing sugar. Moreover, compared with MAP alone, MAPs with MAM of both sachet and sheet styles led to the weight loss of gingers increasing by more than 3-4 times, but sprouting rate, spoilage rate and reducing sugar decreasing by 3.3, 1.4 and 2.3 times, respectively. These results showed that MAP with UM was significantly effective to prolong the freshness of ginger by longer than 2 times, compared with MAP alone.

  • PDF

Effect of Thickness Eccentricity on Plastic Collapse of Subsea Pipeline under External Pressure (외압하에서 해저배관의 소성붕괴에 대한 두께 불균일 효과)

  • Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.14-19
    • /
    • 2011
  • The objective of this study was to investigate the effect of the thickness eccentricity on the collapse pressure of a subsea pipeline subjected to external pressure. The collapse behavior of the subsea pipeline containing initial imperfection was evaluated using elastic-plastic finite element (FE) analyses. API 5L X65 and API 5L X80 Pipelines with the thickness eccentricity values between 4~16% were adopted to investigate the plastic collapse under hydrostatic pressure. A parametric study was shown that the plastic collapse pressure decreased when either the thickness eccentricity or the ratio of diameter to thickness increased.

Correlation between the Thickness and Variation of Dielectric Conatant on SiOC thin film (SiOC 박막에서 박막의 두께와 유전율의 변화)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2505-2510
    • /
    • 2009
  • The SiOC films were deposited with the variation of flow rate ratios by chemical vapor deposition. It was researched the reason of decreasing the dielectric constant in SiOC film and the relationship between the dielectric constant and the thickness. The thickness of the deposited films tends to in proportion to the refractive index and the sample with the lowest dielectric constant decreased the thickness. The refractive index was decreased after annealing because of the decreasing of the film's thickness by annealing process.

Validity of Empirical Formulas for Estimation of Reflection Coefficient of Waves Due to Perforated Wall (유공벽에 의한 파의 반사율 산정에 있어서 경험공식의 타당성)

  • Yoon, Sung Bum;Lee, Jong In;Han, Sang Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.633-639
    • /
    • 2006
  • The validity of the existing formulas for the estimation of reflection coefficient of waves due to perforated wall is investigated using the result of hydraulic experiments conducted with perforated walls of various thickness. The result shows that, when the wall is thick, the energy loss coefficient is reduced to 62% of the value evaluated using the existing formula for sharp-crested orifice. The result also shows that the length of inertia resistance increases linearly as the thickness of the wall increases. The width of chamber to achieve the minimum reflection of waves decreases as the length of inertia resistance increases. Thus, the result found in the present study can be usful for the design of perforated wall.

Eddy Current and Ultrasonic IRIS Signal Characteristics of Reboiler Tube by Using STS 316L Calibration Specimen (STS 316L 교정시험편을 이용한 재가열기 튜브의 와전류신호와 초음파 IRIS 신호 특성)

  • Tak, Kyeong-Joo;Kim, Byung-Il;Gook, Jin-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.56-63
    • /
    • 2012
  • In this study, a field applicability of reboiler tube was evaluated by comparing ECT signal with IRIS signal about wall loss rate and remaining wall thickness using worked austenite STS 316L ASME standard calibration tube. In the case of wall-loss rate, as a result, tolerance about $20%{\times}4$ flat bottom hole and 10% O D groove(ECT), 80% defect and 10% O D groove(IRIS) occurred up to ${\pm}15%$. In the case of remaining wall thickness, ECT was satisfied with the both tolerance, but tolerance about 80% defect occurred up to ${\pm}15%$ in IRIS. Therefore, if the IRIS is performed for interpretation of non-relevant indication and measurement of wall-loss rate after ECT, reliability is supposed to be improved.

Fabrication and Magnetic Properties of Ultrathin Co-based Amorphous Alloy (코발트계 극박형 비정질합금의 형성과 자기적 성질)

  • 노태환
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.255-260
    • /
    • 1998
  • Fabrication condition and magnetic properties of ultrathin Co-based amorphous alloy have been investigated. When the ejection gas pressure was lower than 0.05 kgf/$\textrm{cm}^2$ at the roll speed of 55 m/s, ultrathin ribbons with the thickness less than 10 ${\mu}{\textrm}{m}$ were successfully obtained. The ribbon thickness decreased linearly with the decrease in ejection pressure. Moreover the significant decrease in ribbon width was accompanied with the decrease of thickness in the range of ejection pressure to form an ultrathin ribbon. This behavior was attributed to the decrease of effective ejection pressure in the both end-sides of rectangular nozzle due to the larger friction between molten metal and nozzle wall. The effective permeability at low frequency (1 kHz) decreased largely with the decrease in ribbon thickness, while the coercive force increased with the thickness decrease. It was considered that these behaviors were due to the enhancement of surface effect leading to the suppression of wall motion. However effective permeability at high frequency (1 MHz) increased with the decrease in ribbon thickness, and this was ascribed to the easier magnetization rotation owing to the reduction of eddy current.

  • PDF

Effect of PE Film Thickness on MA (Modified Atmosphere) Storage of Strawberry (Polyethylene Film 두께에 따른 딸기의 MA(Modified Atmosphere) 저장 효과)

  • 김종국;문광덕;손태화
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.1
    • /
    • pp.78-84
    • /
    • 1993
  • This study was conducted to investigate the effect of various polyethylene (PE) film packaging on the quality of strawberry during storage at low temperature. Gas composition in film was changed rapidly at early stage of storage and then kept at the level of 5~10% $CO_2$and 1~3% $O_2$. Weight loss and decay rate were low at 0.08mm PE film packed strawberries. Titratable acidity, pH and soluble solids were changed slightly during storage but its large difference according to film thickness was not observed. Decrease of flesh firm-ness and a value was restrained by PE film packaging. Free sugar of strawberry was composed of glucose and fructose in similar content and it was decreased a little during storage but the difference according to film thickness was not observed. The organic acids in strawberry were citric acid, malic acid, succinic acid, ascorbir acid, oxalic acid, tartaric acid and pyruvic acid and the major organic acid was citric acid. The contents of citric acid, malic acid, succinir acid and ascorbic acid were decreased and oxalic acid and tartaric arid were not changed during storage but pyruvic acid was increased in early stage and then decreased. These changes of organic acid were slight in packaged with 0.08mm PE film strawberry.

  • PDF

A Study on the Plastic Forming by Rotary Swaging Process (Rotary Swaging 공법을 적용한 탄체 소성가공에 관한 연구)

  • Shon, Byoung-Chul;Lee, Ho-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.672-678
    • /
    • 2020
  • Ogive parts of large-caliber ammunition in Korea are manufactured by the Press Nosing method, but this method has the disadvantage of requiring additional processes such as lubrication before and after the press process. This study proposes the possibility of applying the Swaging method to improve these shortcomings. A large-diameter shell body was manufactured in sub-scale and plastic working experiments using a swaging process were performed. We investigated whether plastic processing is possible up to 75 % of the diameter reduction rate that satisfies the final molding dimension, and whether the dimensions of the product produced by swaging molding are satisfactory as the hardness changes according to the diameter reduction rate and the increase in thickness. The test using the prototype confirmed that the hardness increased proportionally with the diameter reduction rate and by more than HV 335 at the reduction rate of 75 %. The material thickness variation tended to be similar to the theoretical calculated value, and the thickness increase rate was proportional to 65.4 % at the reduction rate of 75 %.

Effect of Scatter Media on Small Gamma Camera Imaging Characteristics (방사선원과 감마카메라 사이에 위치한 산란매질이 소형 감마카메라 영상에 미치는 영향 연구)

  • Seo, Hyun-Kwan;Choi, Yong;Im, Ki-Chun; Woo, Sang-Geun;Lee, Jun-Soo;Song, Tae-Yong;Choi, Yeon-Sung;Lee, Kyung-Han;Kim, Byung-Tae;Choi, Young-Il
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 2002
  • Effect of scatter media materials and thickness, located between radioactivity and small gamma camera, on imaging characteristics was evaluated. The small gamma camera developed for breast imaging was consisted of collimator, NaI(T1) crystal(60$\times$60$\times$6 ㎣), PSPMT(position sensitive photomultimplier tube), NIMs and personal computer. Monte Carlo simulation was performed to evaluate the system sensitivity with different scatter media thickness(0~8 cm) and materials(air and acrylic) with parallel hole collimator and diverging collimator. The sensitivity and spatial resolution was measured using the small gamma camera with the same condition applied to the simulation. Counts was decreased by 10%(air) and 54%(acryl) with the parallel hole collimator and by 35%(air) and 63%(acryl) with the diverging collimator. Spatial resolution was decreased as increasing the thickness of scatter media. This study substantiate the importance of a gamma camera positioning and the minimization of the distance between detector and target lesion in the clinical application of a gamma camera.

  • PDF