• Title/Summary/Keyword: 동축케이블

Search Result 102, Processing Time 0.024 seconds

해외동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.8 no.2
    • /
    • pp.83-88
    • /
    • 1997
  • PDF

Propagation Chracteristics of Leaky Coaxial Cable with Periodic Slots (주기적인 슬롯을 갖는 누설동축 케이블의 전파 특성)

  • 홍용인;김현준;맹명채;양기곤;김정기
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.2
    • /
    • pp.24-33
    • /
    • 1993
  • In indoor radio systems, vehicular communication systems, and land mobile systems, a very important problem is that of maintaing stable communications at all locations. Therefore solutions for the indoor propagation problem are an important aspects of the mobile communication system. Leaky coaxial cables finding increasing use in communications systems involving mines, tunnels, railroads, and highways, and in new obstacle detection, or guided radar, schemes for ground transpor- tation and perimeter surveilance. In this paper a leaky coaxial cable having periodic slots in the outer conductor is described to obtain the propagation modes in the various environments. We use an essentric cylindrical model to develop the theory for surface-wave propagation on the cable. Numerical Results are also included for the propagation constants, field distribution and impedance as functions of various parameters. First, we derive the electromagnetic equation for leaky coaxial cable having periodic slots using mode-matching method and Floguet's theorem, and then find various modes, propagation constants, field distribution, etc.

  • PDF

Implementation of condition monitoring system in underground utility tunnels using inductive coupler (유도성 커플러를 이용한 지하공동구의 상태감시시스템)

  • Ju, Woo-Jin;Kim, Hyun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.8
    • /
    • pp.1597-1603
    • /
    • 2017
  • The incidence of fire in underground utility tunnel is lower than other fires, but the damage caused by fire can cause social loss due to social management paralysis as well as economic loss. Hereupon, this paper presents the results of an empirical test on the construction of the underground utility tunnel condition monitoring system using the leakage coaxial cable installed in the underground utility tunnel. For this reason, a verification test was conducted by connecting a inductive coupler 200 Mbps power line communication modem with insertion loss characteristics of $-6{\pm}2dB$ to the installed the leakage coaxial cable installed in the underground utility tunnel. As a result, We confirmed sending/receiving of IP cameras up to 500 m. Therefore, it is judged that it is possible to construct a condition monitoring system for underground utility tunnel by using the leakage coaxial cables installed in the underground utility tunnels without installing additional communication lines for data transmission.

Characteristics and Analysis of CATV Home Networks (CATV 홈 네트워크의 특성 분석)

  • Park, Sung-Wook;Park, Jong-Kwan;Ohm, Woo-Yong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.286-291
    • /
    • 2013
  • Home CATV networks comprise coaxial cables and signal splitters which have less than ideal characteristics. Home network testing facilities use long lengths of coaxial cables, often undesirably coiling and bending the cable, stressing joints on connectors. Cable connectors, cable placement, bending and flexing can cause leakage of signals and can result in undesired signal paths in a system causing deteriorated performance. The purpose of this paper is to bring to light the issues of signal leakage and radiation from shielded media such as RG-59 and RG-6 coaxial cables, furthermore signal splitters have less than ideal characteristics.

A Study on the Numerical Analysis of Reentrant Cavity Resonator by Mode Matching Method and Orthogonality (모드결합법과 모드직교성에 의한 요철형 공진기의 공진주파수 계산)

  • 이승무;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • In this paper, resonance frequencies of a reentrant cavity are computed by the mode matching method and the mode orthogonality. The reentrant cavity is composed of a coaxial cable and a cylindrical waveguide, so that resonance frequencies of the resonator can be varied by adjusting the length of the inner conductor of a coaxial cable. The result can be applied to numerous microwave devices such as klystron, wavemeter and resonant circuits of a amplifier and to the measurement of dielectric parameters.

  • PDF

Development of Monitoring and Control System of Utility-Pipe Conduit(Power Tunnel) using PLC (전력선 통신을 이용한 지하공동구 종합감시제어 시스템 개발)

  • Ju Seong-Ho;Lee Tae-Young;Park Byung-Seok;Lim Yong-Hoon;You Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.728-732
    • /
    • 2004
  • 기존의 지하 공동구 감시 시스템은 광케이블, 누설 동축케이블(LCX), 각종 제어케이블을 사용하여 통신 선로를 구축하기 때문에 시설비가 대단히 고가이며, 여러 가지 통신선로의 이용에 따른 유지보수가 어렵고 시공기간이 길어 시설 확대에 어려움이 있었다. 따라서 통신케이블의 설치 없이 기존에 설치된 공동구의 전등용 저압 전력선을 통신선로로 그대로 이용할 수 있는 전력선 통신 기술을 적용하여 유지보수가 용이한 저비용의 지하 공동구 감시제어시스템을 개발하는 것이 바람직하다. 본 논문에서는 공동구에서의 전력선 통신의 특성을 조사, 시험시스템 설계${\cdot}$제작, 현장실증시험을 통한 성능시험 및 분석을 수행하여 전력선 통신을 적용한 안정적인 공동구 감시제어 시스템을 제안하고자 한다.

  • PDF

Study on HD Analog video surveillance system (HD Analog 영상감시시스템에 관한 연구)

  • Ha, Kyung-Su
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2015.11a
    • /
    • pp.317-318
    • /
    • 2015
  • 이 연구에서는 아날로그 기반의 고화질 전송 시스템(HD Analog system)에 관하여 고찰하였다. 오늘날 영상감시시스템은 고해상도 적용을 위한 기술개발을 통해 고품질의 영상을 구현할 수 있는 HD-SDI나 Network camera로 전환되고 있다. 그러나 Network camera는 기존 시스템과의 현격한 구성 차이로 전체 시스템을 다시 구축해야 하고, HD-SDI는 저가형 케이블 등에서는 만족할 만한 성능이 보장되지 않았다. 이러한 배경에서 등장한 것이 HD Analog system이다. HD Analog system은 기존 동축케이블을 이용할 수 있으며 저가형 케이블에서도 최대 500m 이상 전송이 가능하고, 구축비용을 절감할 수 있는 장점이 있다. 그러나 제조사별 시스템의 호환 문제 등을 해소하기 위한 표준화는 HD Analog system의 성장을 위한 선결과제로 제기된다.

  • PDF

Application of Nano-TDR Health Monitoring System in Civil Engineering (나노-TDR센서를 이용한 토목구조물 모니터링 시스템)

  • Han, Heui-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.93-100
    • /
    • 2009
  • This study presents reasonable relationships to estimate the deformation based on beam mechanism analysis and TDR(Time Domain Reflectometry) data. To declar the length points of co-axial cable installed in civil structure, Nano material ($BaTiO_3$ powders and silver mixture) is used on co-axial cables. From the laboratory test, nano material could make the correct information about attached cable points on beam, and TDR sensor system and Fourier series (data filter) found out the deformation of beam. Therefore it is concluded that the correct deformed information of beam were acquired by Nano-TDR and Fourier filter, they are much more effective to apply at health monitoring system in civil structure compared to conventional TDR or Fiber Optic Sensor (FOS) systems.

Antenna Factor Characteristics of EMI Dipole Antennas with Coaxial Cable Balun for Frequencies between 30 and 1,000 MHz (동축 케이블 밸런이 부착된 30~1,000 MHz 대역용 EMI 다이폴 안테나의 안테나 인자 특성)

  • Ju Chang-Hyun;Kim Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.623-628
    • /
    • 2006
  • This paper presents the characteristics of an antenna factor of two kinds of EMI dipole antennas with a coaxial cable balun used in the frequency range between 30 and 1,000 MHz. The integral equation for unknown current distribution is solved by the Galerkin's method of moments with piecewise sinusoidal functions. An antenna factor for EMI dipole antennas with the coaxial cable balun is derived by using the power loss concepts. We can realize two kinds of EMI dipole antennas with appropriate antenna factors in the frequency range from 30 to 1,000 MHz: 150-cm dipole length($30{\sim}300 MHz$) and 30cm dipole length($300{\sim}1,000 MHz$). To check th ε validity of the theoretical analysis, the complex antenna factor was measured using by reference antenna methods. It is shown that the calculated complex antenna factor is good agreement with experimental results.