• Title/Summary/Keyword: 동적 전단 강도

Search Result 120, Processing Time 0.021 seconds

Shear Resistance of Unreinforced Cast-In-Place Anchors in Uncracked and Cracked Concrete by Seismic Qualification Tests (지진모의실험에 의한 비균열 및 균열콘크리트에 매입된 비보강 선설치앵커의 전단 저항강도 평가)

  • Park, Yong Myung;Kim, Tae Hyung;Kim, Dong Hyun;Jo, Sung Hoon;Lee, Jong Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.347-357
    • /
    • 2015
  • In this study, an experimental study was performed to evaluate the concrete breakout strength of unreinforced cast-in-place anchors by seismic qualification test under shear loading. The CIP anchors tested herein were 30mm in diameter with an edge distance of 150mm and an embedment depth of 240mm in uncracked and cracked concrete. The cracked specimen consisted of orthogonal and parallel crack to the loading direction, respectively. The dynamic loading sequence during the seismic qualification test was determined based on CSA N287.2, ACI 355.2 and ETAG 001 codes. After the dynamic loading, the static loading was applied until failure occurs. The shear resistance by seismic qualification tests showed almost the same strength as that obtained from the static tests in uncrcaked and cracked concrete, respectively. Meanwhile, the breakout depth did not reach $8d_0$, therefore the modified strength equation of ACI 318-11 could estimate properly the concrete breakout strength, which does not consider effective bearing length.

Correlation Analysis of Binder Stiffness with Deformation Strength and Dynamic Creep Property of Asphalt Mixtures for Evaluation of Kim Test Applicability (바인더 Stiffness와 혼합물의 변형강도 및 동적크리프 특성과의 상관성 분석을 통한 김테스트 적용성 고찰)

  • Kim, Kwang-Woo;Doh, Young-Soo;Cho, Mun-Jin
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.91-102
    • /
    • 2005
  • This study dealt with correlation analysis of binder stiffness with deformation strength and dynamic creep property of asphalt mixtures for evaluation of applicability of deformation strength $(S_D)$. Two aggregates, with maximum size of 13mm and eight binders were used to produce 16 different mixtures. The stiffness of binder $(G^*/sin\delta)$ was measured using DSR at $64^{\circ}C$. Final deformation(FD) and dynamic stability(DS) were measured by dynamic creep (DC) test, and SD was measured by Kim test for each mixture. Results of correlation analysis between $G^*/sin\delta$, and $S_D$, m and DS showed that correlation with binder stiffness and deformation strength was the highest $(R^2>0.88)$. There was good correlation between DS, FD with $S_D$. The results indicated that rut-resistance property of mixture is better reflected in $S_D$ test than FD or DS of dynamic creep test. Therefore, it is concluded that $S_D$ can be possibly used for evaluation of rut resistance of asphalt concretes with a good reliability if the procedure is standardized.

  • PDF

Characteristics of ER Fluids with Different Electrode Gaps and Materials (전극재질 및 간긍에 따른 ER유체의 특성실험)

  • 최승복
    • The Korean Journal of Rheology
    • /
    • v.10 no.3
    • /
    • pp.165-172
    • /
    • 1998
  • 본논문에서는 전기장 부하에 따라 유동성질이 변화하는 ER유체의 빙햄특성을 실험 적으로 연구하였다. 특히 ER유체의 빙행특성에 영향을 주는 여러인자중 전극 간격 및 재질 에 따른 ER유체의 항복전단응력과 전류밀도의 변화를 온도에 따라 고찰하였다. 이를 위하 여 전극 간격을 가변시킬수 있는 전기 점도계를 세가지 재질로 자체 제작하였다. 전극간격 은 0.75 mm, 1.00mm 및 1.25 mm 로 설정하였으며 전극 재질은 스테인레스 스텔, 동 그리 고 기계구조용 탄소강(SMS45C)을 사용했다. 한편 실험에 사용된 ER유체는 자체 조성한 수 계 ER유체인 ERF-1과 외국의 우수하다고 알려진 비수계 ER유체인 ERF-2 두가지를 선택 하였다. 실험은 $25^{\circ}C$와 7$0^{\circ}C$ 및 10$0^{\circ}C$에서 수행하였으며 전기장은 0-4kV/mm 범위에서 온 도 및 ER유체의 종류에 따라 부하 가능한 전압까지 공급하였다. 전단변형률 50, 100, 150, 200, 400, 600, 800, 1000 및 1200 s-1에서 얻은 전단응력 실험결과로부터 최소오차선형법을 이용하여 전단변형률 영에서 동적 항복전단응력 값을 도출하였으며 그결과로부터 전극 간격 및 재질에 따른 ER효과의 변화를 고찰하였다. 또한 상온과 10$0^{\circ}C$에서 4kV/mm의 전기장을 부하하여 전기장에대한 ER유체의 응답특성을 실험을 수행했다.

  • PDF

Physical Weathering Characteristics of Mica-Schist in Sinbuk Area, Chuncheon, Korea (춘천시 신북지역에 분포하는 운모편암의 물리적 풍화특성)

  • Woo, Ik;Han, Byeong-Hyeon
    • Economic and Environmental Geology
    • /
    • v.40 no.6
    • /
    • pp.771-784
    • /
    • 2007
  • This study shows the weathering characteristics of mica-schist affected by faulting and metamorphism through laboratory tests. Frozen-thaw test, which simulate the physical-chemical weathering processes in the laboratory, shows the important influence of foliation developed in mica-schist, resulting in $20{\sim}40%$ reduction of UCS according to weathering grade of rock. Slaking durability test was carried out for different weathering grade rock specimens and indicated that the specimens from fault area had a low durability index compared to other relatively fresh samples. XRD analysis allowed to estimate the dynamic evolution of mineral composition through wet-dry cycle in which the chlorite was the most important mineral leached out during slaking test. The creep test indicated that the main deformation produced along the foliation plane. The compacted clay minerals between discontinuity planes influence on the discontinuity shearing properties and result in a big difference between peak shear strength and residual strength. The results of laboratory tests on mica-schist show the possibility of a important deformation along the foliation plane or discontinuity.

Characteristics of Dynamic Shear Behavior of Pile-Soil Interface Considering pH Conditions of Groundwater (지하수 pH조건을 고려한 말뚝-지반 접촉면의 동적 전단거동 특성)

  • Kwak, Chang-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.5
    • /
    • pp.5-17
    • /
    • 2022
  • A pile is a type of medium for constructing superstructures in weak geotechnical conditions. A pretensioned spun high-strength concrete (PHC) pile is composed of high-strength concrete with a specified strength greater than 80 MPa. Therefore, it has advantages in resistance to axial and bending moments and quality control and management since it is manufactured in a factory. However, the skin friction of a pile, which accounts for a large portion of the pile bearing capacity, is only approximated using empirical equations or standard penetration test (SPT) N-values. Particularly, there are some poor research results on the pile-soil interface under the seismic loads in Korea. Additionally, some studies do not consider geoenvironmental elements, such as groundwater pH values. This study performs sets of cyclic simple shear tests using submerged concrete specimens for 1 month to consider pH values of groundwater and clay specimens composed of kaolinite to generate a pile-soil interface. 0.2 and 0.4 MPa of normal stress conditions are considered in the case of pH values. The disturbed state concept is employed to express the dynamic behavior of the interface, and the disturbed function parameters are newly suggested. Consequently, the largest disturbance increase under basic conditions is observed, and an early approach to the failure under low normal stress conditions is presented. The disturbance function parameters are also suggested to express this disposition quantitatively.

A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection (철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Lee, Jong Bo;Won, Deok Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.267-275
    • /
    • 2012
  • This paper describes the experimental study on the structural behavior of the joint plane between a RC(Reinforced Concrete) wall and a SC(Steel Plate Concrete) wall under out-of plane flexural loads and in-plane shear loads. The test specimens were produced with L and I shape to assess efficiently flexural and shear behavior of the structures. In order to consider dynamic loads such as earthquake, cyclic loading tests were carried out. As results of the out-of plane flexural tests, ductile failure mode of vertical bars was shown under a push load and the failure load was more than nominal strength of the specimen. And the latter test was performed to verify the variation which was composition presence of horizontal bars in the SC member. The test results showed that capacity of the specimens was more than their nominal strength regardless of composition presence of horizontal bars.

A Simple Model for the Nonlinear Analysis of an RC Shear Wall with Boundary Elements (경계요소를 가진 철근콘크리트 전단벽의 비선형 해석을 위한 간편 모델)

  • Kim, Tae-Wan;Jeong, Seong-Hoon;You, Tae-Sang
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.45-54
    • /
    • 2011
  • A simple model for reinforced concrete shear walls with boundary elements is proposed, which is a macro-model composed of spring elements representing flexure and shear behaviors. The flexural behaviour is represented by vertical springs at the wall ends, where the moment strength and rotational capacity of the wall are based on section analysis. The shear behaviour is represented by a horizontal spring at the wall center, where the key parameters for the shear behavior are based on the flexural behaviour since the shear walls with boundary elements are governed by the flexure. The proposed model was prepared with the results of hysteretic tests of the shear walls, and then the reliability of the hysteretic rule and variables was investigated by nonlinear dynamic analyses. Using parametric study with nonlinear dynamic analyses, the effect of the variables on demand and capacity, which are major parameters in seismic performance evaluation, are investigated. Results show that the measured and calculated shear forces versus the shear distortion relationships are slightly different, but the global response is well simulated. Furthermore, the demand and capacity are also changed in a similar way to the change in the major parameters so that the proposed model may be appropriate for reinforced concrete shear walls with boundary elements.

The Effect of Cyclic Load Frequency on the Liquefaction Strength of Fine Containing Sands (세립분을 포함하는 모래질 흙의 액상화강도에 미치는 재하속도의 영향)

  • 황대진
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.119-132
    • /
    • 1994
  • Undrained cyclic triaxial tests were performed on silt contained in the sand in order to investigate the effect of silt contents on the liquefaction strength and shear characterist ifs of the sand. As the result of this experiment, the weakest percentage of silt contained in the sand was 30% for all the relative density considered in the test. Also, the same bests were performed to find the effect of cyclic speed applied ranging from 0.1Hz to 5Hz on the liquefaction strength. The more the silt is contained in the sand, the greater the liquefaction strength was affected by cyclic speed, While the silt -containing sand was far less influenced by the cyclic speed than clay containing sand. These results are believed to be caused by the change of pore water pressure of the effective stress path.

  • PDF

Evaluation of Wettability and Interfacial Property of Glass Fiber Reinforced Composite with Different Glass Fiber Conditions via Capillary Effect (Capillary 특성을 활용한 섬유 조건에 따른 유리섬유강화 복합재료의 함침성 및 계면강도 평가)

  • Kim, Jong-Hyun;Kwon, Dong-Jun;Park, Joung-Man
    • Composites Research
    • /
    • v.34 no.5
    • /
    • pp.305-310
    • /
    • 2021
  • Mechanical properties of fiber reinforced composites were affected to fiber volume fractions (FVF) and interfacial property by sizing agent conditions. An optimum interface can relieve stress concentration by transferring the mechanical stress from the matrix resin to the reinforcements effectively, and thus can result in the performance of the composites. The interfacial properties and wettability between the epoxy resin and glass fiber (GF) were evaluated for different sizing agent conditions and FVFs. The surface energies of epoxy resin and different sizing agent treated GFs were calculated using dynamic and static contact angle measurements. The work of adhesion, Wa was calculated by using surface energies of epoxy matrix and GFs. The wettability was evaluated via the GF tow capillary test. The interfacial shear strength (IFSS) was evaluated by microdroplet pull-out test. Finally, the optimized GFRP manufacturing conditions could be obtained by using wettability and interfacial property.

An Experimental Study for the Liquefaction Resistance Strength of Saturated Sand Using Real Earthquake Loading (실지진하중을 이용한 포화사질토의 액상화 저항강도에 관한 실험적 연구)

  • 심재욱;박근보;최재순;김수일
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.329-337
    • /
    • 2002
  • Based on the equivalent uniform stress concept presented by Seed and Idriss, sinusoidal cyclic loads which simplified the earthquake loads have been applied in evaluating the liquefaction resistance strength experimentally. However, the liquefaction resistance strength of soil based on the equivalent uniform stress concept can not exactly reflect the dynamic characteristics of the irregular earthquake motion. In this study, the criterion of the liquefaction resistance strength was determined by applying real earthquake loading to the cyclic triaxial test. From the test results, relationships between liquefaction behaviors of saturated sand and earthquake characteristics such as magnitude or time-duration were determined. Magnitude scaling factors to determine the soil liquefaction resistance strength in seismic design were also proposed.