Experimental Study on Deformation and Failure Behavior of Limestones under Dynamic Loadings (동적하중 하에서 석회암의 변형 및 파괴거동에 관한 실험적 연구)

  • Kang, Myoung-Soo;Kang, Hyeong-Min;Kim, Seung-Kon;Cheon, Dae-Sung;Kaneko, Katsuhiko;Cho, Sang-Ho
    • Tunnel and Underground Space
    • /
    • v.22 no.5
    • /
    • pp.339-345
    • /
    • 2012
  • Information on the deformation behavior and fracture strength of rocks subjected to dynamic loadings is important to stability analyses of underground openings underground vibration due to rock blasts, earthquakes and rock bursts. In this study, Split Hopkinson Pressure Bar (SHPB) system was applied to estimate dynamic compressive and tensile fracture strengths of limestone and also examine deformation behavior of limestones under dynamic loadings. A micro-focus X-ray CT scanner was used to observe non-destructively inside the impacted limestone specimens. From the dynamic tests, it was revealed that the limestone have over 140MPa dynamic compressive strength and the strain-rate dependency of the strength. Dynamic Brazilian tensile strength of the limestone exceeds 21MPa and shows over 3 times static Brazilian tensile strength.

Evaluation of Dynamic Tensile Strength of HPFRCC According to Compressive Strength Level (압축강도 수준에 따른 HPFRCC의 동적충격 인장강도 평가)

  • Park, Gi-Joon;Kim, Won-Woo;Park, Jung-Jun;Moon, Jae-Heum;Kim, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.31-37
    • /
    • 2018
  • This study evaluates the dynamic tensile behavior of HPFRCC according to compressive strength levels of 100, 140 and 180 MPa. Firstly, the compressive stress-strain relationship of 100, 140 and 180 MPa class HPFRCC was analyzed. As a result, the compressive strengths were 112, 150 and 202 MPa, respectively, and the elastic modulus increased with increasing compressive strength. The static tensile strengths of HPFRCC of 100, 140 and 180 MPa were 10.7, 11.5 and 16.5 MPa, and tensile strength also increased with increasing compressive strength. On the other hand, static tensile strength and energy absorption capacity at 100 and 140 MPa class HPFRCC showed no significant difference according to the compressive strength level. It was influenced by the specification of specimen and the arrangement of steel fiber. As a result of evaluating the dynamic impact tensile strength of HPFRCC, tensile strength and dynamic impact factor of all HPFRCCs tended to increase with increasing strain rate from 10-1/s to 150/s. In the same strain rate range, the DIF of the tensile strength was measured higher as the compressive strength of HPFRCC was lower. It is considered that HPFRCC of 100 MPa is the best in terms of efficiency. Therefore, it is advantageous to use HPFRCC with high compressive strength when a high level of tensile performance is required, and it is preferable to use HPFRCC close to the target compressive strength for more efficient approach at a high strain rate such as explosion.

The influence of dynamic force balance on the estimation of dynamic uniaxial compression strength (암석시료 내 동적하중 분배특성이 동적일축압축강도에 미치는 영향성에 관한 연구)

  • Oh, Se-Wook;Min, Gyeong-Jo;Park, Se-Woong;Park, Hoon;Suk, Chul-Gi;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.37 no.1
    • /
    • pp.14-23
    • /
    • 2019
  • It has been an always issue for the blasting or the impact analysis to consider the strength characteristics of the rock materials associate with loading rate dependency. Due to the nature of transient loading, the dynamic rock test requires a careful technique to achieve the stress equilibrium state of the specimen. In this study, to investigate the relationship between the rock dynamic strength and the stress equilibrium state, a series of dynamic uniaxial compression tests for Pocheon granite were performed. As a result, the unbalanced stress state on the specimen can lead to the premature failure on the specimen and the less estimation of dynamic strength characteristic as well as the overestimation of strain rate. Consequently, a careful consideration of rock fracture process to achieve the dynamic force balance on the specimen should be required to make an reasonable evaluation of rock dynamic strength.

Experimental Study on Dynamic Characteristics of Vibration-Controlled Concrete Beam (제진 콘크리트 보의 동적특성에 관한 실험적 연구)

  • 정영수;최우성;이대형
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.6
    • /
    • pp.185-193
    • /
    • 1997
  • 본 연구는 각종 제진재료를 이용하여 진동을 억제할 수 있는 콘크리트를 개발하여 각종 건설공사에서 흔히 발생할 수 있는 진동공해문제를 억제하고자 하며 아울러 폐기물의 재활용차원에서 폐자재를 이용하여 유용한 제진콘크리트를 개발하고자 하는데 그 목적이 있다. 우선, 제진재료를 이용한 압축강도 (200kg/$\textrm{cm}^2$)이상의 콘크리트 배합비를 찾기 위하여 24배치의 예비실험을 수행하였으며, 선정된 적정배합비에 따른 제진재료를 이용한9개의 진동시험체보를 제작하여 보의 구조적 및 재료적 동적특성 즉 1차 공명진동수와 동적 휨강성 및 감쇠비를 측정하여 제진효과를 조사하였다. 그리고 압축강도에 의한 각 시험체의 균열모멘트를 추정하여 재하하중과 균열모멘트비(M/Mcr)에 따른 하중단계별 동적특성값을 살펴보았다. 제진재료로서는 라텍스(Latex), 고무분말(Rubber Powder)그리고 플라스틱 레진( Plastic Resin)등을 사용하였고, 재료적, 구조적 진동감쇠효과를 파악하고자 KS F2437규정과 진동파의 속도법을 사용하였으며, 감쇠비 측정은 Frequency Spectrum 곡선에 대한 Polynomial Curvefitting 방법과 기하학적 해석방법을 이용하여 각각의 결과를 비교.분석하였다.

Experimental Study on the Material Properties of Unreinforced Masonry Considering Earthquake Load (지진하중을 고려한 비보강 조적조의 재료특성 평가에 관한 실험연구)

  • 김희철;김관중;박진호;홍원기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.93-101
    • /
    • 2001
  • 본 논문은 국내의 비보강 조적조에 대해 내진성능을 조사하기 위하여 재료측성 평가를 위한 실험연구를 수행하였다. 실험결과를 바탕으로 조적용 모르터의 압축강도식을 제안하였다. 또한 조적용 모르터의 배합비에 따른 조적조 프리즘의 압축강도 특성을 비교하였다. 조적조 프리즘의 압축강도로써 조적조의 탄성계수를 구할 수 있는 약산식을 제시하였으며, 약산식을 사인장 조적조 실험을 통하여 구한 전단탄성계수값과 비교하여 볼 때 타당성을 가지고 있다고 판단된다. 실험결과로써 나온 재료특성 값을 바탕으로 2층 조적조 다세대 주택에 대한 유사동적해석을 수행하였다. 해석결과로 얻은 전단응력과 전단파괴가 나타난 사인장 조적조의 허용전단응력은 유사한 것으로 확인되었다.

  • PDF

Unconfined Compressive Strength Characteristics and Time Dependent Behavior of Soil-Cement (소일시멘트의 일축압축강도 특성 및 시간의존 거동)

  • Kim, Jong-Ryeol;Kang, Hee-Bog;Kang, Hwa-Young;Kim, Do-Hyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.87-96
    • /
    • 2004
  • As a special concrete, which is a mixture of soil, cement and water, has strength like regular concrete for pavement, soil cement has been used in various field such as pavement and soft soil improvement. The objective of this study was to investigate the characteristic of unconfined compressive strength and time dependent behavior of soil cement that is made from decomposed granite soil or coluvial and inorganic solidification liquid. The results showed that the unconfined compressive strength appears to increase as the amount of cement and curing time increase In addition, the strength seems to decrease with increase of the potion of fine particles(No 200 sieve). The result of XRD indicated that there is Vermiculite, the product of reaction, in the soil cement. The dynamic properties of material, such as shear complex compliance, shear complex modulus, and phase angle could be calculated from the hysteresis loop obtained from the Haversine Creep Tests. Finally, creep behavior was able to be predicted from these dynamic properties.

Dynamic Stability Analysis of Axial Compressor Baldes end Vanes (축류 압축기 블레이드와 베인의 동적 안정성 평가에 관한 연구)

  • 정규강;박희용;김명섭;김용련;김유일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.39-39
    • /
    • 2000
  • 축류 압축기 블레이드(blade)와 베인(vane)이 정하중(static load)에서 충분한 강도를 지니고 있더라도 반복하중이나 교번하중을 받게되면, 그 하중이 작더라도 파괴가 일어날 수 있다. 축류 압축기 블레이드와 베인의 피로파괴(fatigue failure) 현상은 개발 중인 가스터빈엔진 뿐만 아니라 현재 운용중인 엔진에서도 발생할 수 있는 엔진손상의 주요 원인이다. 블레이드나 베인의 동적 안정성 평가는 에어포일(airfoil)의 피로특성과 엔진운용조건에 따라서 발생하는 복잡한 공력가진과의 연관성을 고려하여 수행되어야 하기 때문에, 해석과 구성품 시험을 통하여 우선적으로 강도 평가를 실시하여야 한다.(중략)

  • PDF

Dynamic Effects for Crushing Strength of Rectangular Tubular Members (사각 튜브 부재의 압괴강도에 대한 동적 영향 평가)

  • P.D.C.,Yang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 1990
  • When a thin walled member is subjected to compression in a condition such as collision, the energy is mainly absorbed by axial crumpling. In this case, dynamic crushing strength of the member is increased due to the effects of strain-rate compared with the static strength, even though the inertia effect is neglected. In this paper, the method of predicting the static crushing for tubular members is presented using the kinematic method of plasticity. Since, a predicted crushing load, taking account of the dynamic yield stress, usually overestimates the effects of strain-rate, the average plastic flow stress for the effects of strain-rate is used to obtain the dynamic crushing load for tubular members. The analytical results are compared with the experiments published in references, and a good correlation is observed.

  • PDF

Curing Characteristics of Controlled Low Strength Material Made with Coal Ashes (석탄회를 사용한 저강도 고유동화재의 경화 특성 분석)

  • Kim, Juhyong;Cho, Samdeok;Kong, Jinyoung;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.77-85
    • /
    • 2010
  • Unconfined compressive strength tests were performed to evaluate curing characteristics of controlled low strength material(CLSM) made with coal ashes. It is found that unconfined compressive strength normalized by curing times, increases as decreasing the water contents of CLSM particularly during first three days. Dynamic cone penetrometer tests were also carried out to evaluate cost-effective CLSM lump strength characteristics with time. It takes around 10 days to reach target strength, 500kPa (penetration rate, 20mm/blow). Curing rate significantly decreases after 10 days elapsed regardless of CLSM formulation.

Strain Rate Effect on the Compressive and Tensile Strength of Hooked Steel Fiber and Polyamide Fiber Reinforced Cement Composite (변형 속도에 따른 후크형 강섬유 및 폴리아미드섬유보강 시멘트 복합체의 압축 및 인장강도 특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.76-85
    • /
    • 2017
  • In this study, to evaluate the mechanical properties of fiber-reinforced cement composites by strain rate, hydraulic rapid loading test system was developed. And compressive and tensile strength of the hooked steel fiber and polyamide fiber reinforced cement composite were evaluated. As a result, the compressive strength, strain capacity and elastic modulus were increased with increasing strain rate. The effect of compressive strength by type and volume fraction of fibers was not significant. The dynamic increase factor(DIF) of the compressive strength was higher than that of the CEB-FIP model code 2010 and showed a trend similar to that of ACI-349. The tensile strength and strain capacity were increased with increasing strain rate. The hooked steel fibers were drawn from the matrix. The tensile strength and strain capacity of hooked steel fiber reinforced cement composites were increased as the strain rate increased. The tensile strength and deformation capacity of the fiber reinforced cement composites were increased. And, hooked steel fibers were drawn from the matrix. On the other hand, because the bonding properties of polyamide fiber and matrix is large, polyamide fiber was cut-off with out pullout from matrix. The strain rate effect on the tensile properties of polyamide fiber reinforced cement composites was found to be strongly affected by the tensile strength of the fibers.