• Title/Summary/Keyword: 동잡음 검출

Search Result 42, Processing Time 0.024 seconds

Interference Fringe Signal Filtering Method for Performance Enhancing of White Light Interfrometry (가간섭 영역 외의 배경 잡음성 간섭무늬 신호 필터링을 통한 백색광 주사간섭계의 성능 향상)

  • Yim, Hae-Dong;Lee, Min-Woo;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.272-275
    • /
    • 2009
  • In order to enhance the background noise filtering performance of the white light interferometry(WLI), we demonstrate the noise filtering performance of preprocessing of the measured fringe signals. The WLI was realized through a mirau interferometer which was equipped with a green LED. When measuring large-height and rough surface objects, the illumination optics are considered the numerical aperture(NA) and the depth of focus(DOF). In this case, the limited NA of the illumination optics has a considerable impact on the interference fringe. Therefore, we propose a preprocessing method that uses the intensity difference between the measured intensity and the moving average intensity. The performance is demonstrated by measuring an array of metal solder balls fabricated on printed circuit board(PCB). The proposed method reduces the noise pixels by 15 percent.

Study on the Detection the Section with the Motion Artifacts of the PPG Signal (PPG 신호의 동잡음 구간 검출에 관한 연구)

  • Lee, Hanwook;Lee, Gunki
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • The biomedical information (heart rate, HRV, $SpO_2$ etc) from the Photoplethysmography (PPG) signal section can be estimated without the motion artifacts if the PPG signal section in the motion artifacts is detected accurately. But the PPG signal is easily exposed to the motion artifacts by the decrease of the medical instrument size and applying as portable or wearable. Besides, it is difficult to completely eliminate the motion artifacts from the PPG signal without distortion and ensure reliability as well. In this paper, the method was suggested to determine the motion artifacts or not on the PPG signal of the section divided into intervals of constant length. By comparing the spectrum of each section, it can be determined whether the motion artifacts are or not after obtaining the spectrum of each section by the Goertzel algorithm. Moreover, an amount of computation while maintaining a high detection rate can be reduced by using the Goertzel algorithm.

Development of Continuous ECG Monitor for Early Diagnosis of Arrhythmia Signals (부정맥 신호의 조기진단을 위한 연속 심전도 모니터링 기기 개발)

  • Choi, Junghyeon;Kang, Minho;Park, Junho;Kwon, Keekoo;Bae, Taewuk;Park, Jun-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.45-50
    • /
    • 2021
  • With the recent development of IT technology, research and interest in various bio-signal measuring devices are increasing. But studies related to ECG(electrocardiogram), which is one of the most representative bio-signals, particularly arrhythmic signal detection, are incomplete. Since arrhythmia has various causes and has a poor prognosis after onset, preventive treatment through early diagnosis is best. However, the 24-hour Holter electrocardiogram, a tool for diagnosing arrhythmia, has disadvantages in the limitation of use time, difficulty in analyzing motion artifact due to daily life, and the user's real-time alarm function in danger. In this study, an ECG and pulse monitoring device capable of continuous measurement for a long time, a real-time monitoring app, and software for analysis were developed, and the trend of the measured values was confirmed. In future studies, research on derivation of quantitative results of ECG signal measurement analysis is required, and further research on the development of an arrhythmic signal detection algorithm based on this is required.

LDPC Coding for image data and FPGA Implementation of LDPC Decoder (영상 정보의 LDPC 부호화 및 복호기의 FPGA구현)

  • Kim, Jin Su;Jaegal, Dong;Byon, Kun Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.887-890
    • /
    • 2009
  • To transmit information over a channel in the presence of noise, there needs some technique to code the information. One of the coding techniques used for error detection and correction close to the Shannon limit is Low Density Parity Code. LDPC and decoding characteristic features by sum-product algorithm are matched for the performance to Turbo Code, RA(Repeat Accumulate) code, in case of very long code length of LDPC surpass their performance. This paper explains LDPC coding scheme of image data and decoding scheme, implements LDPC decoder in FPGA.

  • PDF

Human Gesture Recognition Technology Based on User Experience for Multimedia Contents Control (멀티미디어 콘텐츠 제어를 위한 사용자 경험 기반 동작 인식 기술)

  • Kim, Yun-Sik;Park, Sang-Yun;Ok, Soo-Yol;Lee, Suk-Hwan;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1196-1204
    • /
    • 2012
  • In this paper, a series of algorithms are proposed for controlling different kinds of multimedia contents and realizing interact between human and computer by using single input device. Human gesture recognition based on NUI is presented firstly in my paper. Since the image information we get it from camera is not sensitive for further processing, we transform it to YCbCr color space, and then morphological processing algorithm is used to delete unuseful noise. Boundary Energy and depth information is extracted for hand detection. After we receive the image of hand detection, PCA algorithm is used to recognize hand posture, difference image and moment method are used to detect hand centroid and extract trajectory of hand movement. 8 direction codes are defined for quantifying gesture trajectory, so the symbol value will be affirmed. Furthermore, HMM algorithm is used for hand gesture recognition based on the symbol value. According to series of methods we presented, we can control multimedia contents by using human gesture recognition. Through large numbers of experiments, the algorithms we presented have satisfying performance, hand detection rate is up to 94.25%, gesture recognition rate exceed 92.6%, hand posture recognition rate can achieve 85.86%, and face detection rate is up to 89.58%. According to these experiment results, we can control many kinds of multimedia contents on computer effectively, such as video player, MP3, e-book and so on.

Digital watermarking algorithm for authentication and detection of manipulated positions in MPEG-2 bit-stream (MPEG-2비트열에서의 인증 및 조작위치 검출을 위한 디지털 워터마킹 기법)

  • 박재연;임재혁;원치선
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.5
    • /
    • pp.378-387
    • /
    • 2003
  • Digital watermarking is the technique that embeds invisible signalsincluding owner identification information, specific code, or pattern into multimedia data such as image, video and audio. Watermarking techniques can be classified into two groups; robust watermarking and fragile(semi-fragile) watermarking. The main purpose of the robust watermarking is the protection of copyright, whereas fragile(semi-fragile) watermarking prevents image or video data from illegal modifications. To achieve this goal watermark should survive from unintentional modifications such as random noise or compression, but it should be fragile for malicious manipulations. In this paper, an invertible semi-fragile watermarkingalgorithm for authentication and detection of manipulated location in MPEG-2 bit-stream is proposed. The proposed algorithm embeds two kinds of watermarks, which are embedded into quantized DCT coefficients. So it can be applied directly to the compressed bit-stream. The first watermark is used for authentication of video data. The second one is used for detection of malicious manipulations. It can distinguish transcodingin bit-stream domain from malicious manipulation and detect the block-wise locations of manipulations in video data. Also, since the proposed algorithm has an invertible property, recovering original video data is possible if the watermarked video is authentic.

A Study on the Generation of Ultrasonic Binary Image for Image Segmentation (Image segmentation을 위한 초음파 이진 영상 생성에 관한 연구)

  • Choe, Heung-Ho;Yuk, In-Su
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.571-575
    • /
    • 1998
  • One of the most significant features of diagnostic ultrasonic instruments is to provide real time information of the soft tissues movements. Echocardiogram has been widely used for diagnosis of heart diseases since it is able to show real time images of heart valves and walls. However, the currently used ultrasonic images are deteriorated due to presence of speckle noises and image dropout. Therefore, it is very important to develop a new technique which can enhance ultrasonic images. In this study, a technique which extracts enhanced binary images in echocardiograms was proposed. For this purpose, a digital moving image file was made from analog echocardiogram, then it was stored as 8-bit gray-level for each frame. For an efficient image processing, the region containing the heat septum and tricuspid valve was selected as the region of interest(ROI). Image enhancement filters and morphology filters were used to reduce speckle noises in the images. The proposed procedure in this paper resulted in binary images with enhanced contour compared to those form the conventional threshold technique and original image processing technique which can be further implemented for the quantitative analysis of the left ventricular wall motion in echocardiogram by easy detection of the heart wall contours.

  • PDF

Facial Contour Extraction in Moving Pictures by using DCM mask and Initial Curve Interpolation of Snakes (DCM 마스크와 스네이크의 초기곡선 보간에 의한 동영상에서의 얼굴 윤곽선 추출)

  • Kim Young-Won;Jun Byung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.58-66
    • /
    • 2006
  • In this paper, we apply DCM(Dilation of Color and Motion information) mask and Active Contour Models(Snakes) to extract facial outline in moving pictures with complex background. First, we propose DCM mask which is made by applying morphology dilation and AND operation to combine facial color and motion information, and use this mask to detect facial region without complex background and to remove noise in image energy. Also, initial curves are automatically set according to rotational degree estimated with geometric ratio of facial elements to overcome the demerit of Active Contour Models which is sensitive to initial curves. And edge intensity and brightness are both used as image energy of snakes to extract contour at parts with weak edges. For experiments, we acquired total 480 frames with various head-poses of sixteen persons with both eyes shown by taking pictures in inner space and also by capturing broadcasting images. As a result, it showed that more elaborate facial contour is extracted at average processing time of 0.28 seconds when using interpolated initial curves according to facial rotation degree and using combined image energy of edge intensity and brightness.

An Automatic Segmentation Method for Video Object Plane Generation (비디오 객체 생성을 위한 자동 영상 분할 방법)

  • 최재각;김문철;이명호;안치득;김성대
    • Journal of Broadcast Engineering
    • /
    • v.2 no.2
    • /
    • pp.146-155
    • /
    • 1997
  • The new video coding standard Iv1PEG-4 is enabling content-based functionalities. It requires a prior decomposition of sequences into video object planes (VOP's) so that each VOP represents moving objets. This paper addresses an image segmentation method for separating moving objects from still background (non-moving area) in video sequences using a statistical hypothesis test. In the proposed method. three consecutive image frames are exploited and a hypothesis testing is performed by comparing two means from two consecutive difference images. which results in a T-test. This hypothesis test yields a change detection mask that indicates moving areas (foreground) and non-moving areas (background), Moreover. an effective method for extracting

  • PDF

Study on Rector Dynamic Response by Cross Correlation Method (상호상관함수법에 의한 원자로 동특성에 관한 연구)

  • 고병준
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.10 no.4
    • /
    • pp.60-73
    • /
    • 1973
  • The reactor noise analysis was performed by the cross correlation method using two detectors to determine the dynamic stability and the system parameter of TRIGA Mark-II reactor under critical and subcritical conditions. The a values turned out to be 46.67 and 70.04 respectively at zero power and full power under critical condition, while 79.47 and 97.59 respectively at the safety rod dropping and the regulating rod dropping under subcritical condition. Prompt neutron life time of TRIGA Mark-II reactor measured 107 and 160 $\mu$sec, and shut down margin was -10.03$\times$10-4 at the safety rod dropping and -29-43$\times$10-4 at the regulating rod dropping CDC 3100/MSOS digital computer, HITACHI 505 Analog computer, and preamplifier, bandpass filter, FM modulator or demodulator designed for this specific purpose, were employed for the present investigation.

  • PDF