• Title/Summary/Keyword: 동작센싱

Search Result 163, Processing Time 0.018 seconds

Design of 5V NMOS-Diode eFuse OTP IP for PMICs (PMIC용 5V NMOS-Diode eFuse OTP IP 설계)

  • Kim, Moon-Hwan;Ha, Pan-Bong;Kim, Young-Hee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.2
    • /
    • pp.168-175
    • /
    • 2017
  • In this paper, a 5V small-area NMOS-diode eFuse OTP memory cell is proposed. This cell which is used in PMICs consists of a 5V NMOS transistor and an eFuse link as a memory part, based on a BCD process. Also, a regulated voltage of V2V ($=2.0V{\pm}10%$) instead of the conventional VDD is used to the pull-up loads of a VREF circuit and a BL S/A circuit to obtain a wider operational voltage range of the eFuse memory cell. When this proposed cells are used in the simulation, their sensing resistances are found to be $15.9k{\Omega}$ and $32.9k{\Omega}$, in the normal read mode and in the program-verify-read mode, respectively. Furthermore, the read current flowing through a non-blown eFuse is restricted to $97.7{\mu}A$. Thus, the eFuse link of a non-blown eFuse OTP memory cell is kept non-blown. The layout area of the designed 1kb eFuse OTP memory IP based on Dongbu HiTek's BCD process is $168.39{\mu}m{\times}479.45{\mu}m(=0.08mm^2)$.

Design of Indoor Electric Moving and Lifting Wheelchair with Minimum Rotation Radius and Obstacle Overcoming (최소 회전반경 및 장애물 극복형 실내 전동 이·승강 휠체어의 설계)

  • Kim, Young-Pil;Ham, Hun-Ju;Hong, Sung-Hee;Ko, Seok-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.415-424
    • /
    • 2019
  • In this paper, a minimum rotation radius was designed and fabricated to overcome the threshold so that elderly or disabled people who have difficulty moving can move and transfer safely and conveniently in a narrow room. In the indoor environment, where the sedentary culture develops, this study aimed to provide convenience for passengers with fracture diseases, geriatric diseases, and other knee and waist diseases. First, links, seats, armrests, covers, motors, batteries, chargers, controllers, etc. were attached to the frame so that they could be moved and lifted indoors. The product design and structure were designed considering the user's environment and physical characteristics, and IoT functions were added. A driving experiment was performed to confirm the operating performance of the manufactured indoor moving and lifting wheelchair. The performance tests, such as continuous running time, turning radius, maximum actuator load, maximum lift height, sound pressure level, minimum sensing distance of the driving aid sensor, interworking of server and app programs, device compatibility, and duty cycle error rate, were performed. As a result of the test, the built-in wheelchair could achieve the performance test target of each item and operate successfully.

Comparative analysis of fusion factors affecting the accuracy of injection amount of remote fluid monitoring system (원격 수액모니터링 시스템의 주입량의 정확도에 영향을 주는 융합인자의 비교 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.125-131
    • /
    • 2022
  • Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.