• Title/Summary/Keyword: 동공 크기

Search Result 108, Processing Time 0.024 seconds

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

Pupil tracking using Hybrid camera setup for Subhologram display (서브 홀로그램 디스플레이를 위한 하이브리드 카메라 기반 동공 추적)

  • Choo, Hyon-Gon;Park, Min-Sik;Kim, Hyun Eui;Moon, Kyung Ae;Kim, Jin Woong
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.11a
    • /
    • pp.112-113
    • /
    • 2013
  • 서브 홀로그램 디스플레이는 디지털 홀로그래피 디스플레이의 제한된 시역을 관찰자의 동공 크기로 맞게 구현하여 사용자가 더 넓은 범위에서 더 큰 영상을 느끼도록 만드는 홀로그래픽 디스플레이이다. 본 논문에서는 서브홀로그램 방식에서 시야 창 문제를 해결하기 위해, Depth 카메라와 스테레오 카메라의 하이브리드 구성을 이용하여 정밀한 사용자 동공 추적 기법에 대해서 제안한다. 저해상도의 깊이 카메라의 얼굴 인식 정보를 바탕으로 고해상도 스테레오 카메라에서의 얼굴 및 눈의 후보영역을 찾고, 고해상도 스테레오 카메라에서 후보 영역 내의 동공 위치를 잦아서 빠르면서도 정밀한 동공 추적이 가능하도록 하였다.

  • PDF

Changes of Refractive Errors Caused by Corneal Shape and Pupil Size (각막지형과 동공크기에 의한 굴절교정값의 변화)

  • Noh, Yeon Soo;Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.383-387
    • /
    • 2014
  • Purpose: To investigate the effect of corneal unique shape to changes of refractive full corrections when pupil size changes. Methods: Subjective refraction for monocular full correction was performed to 30 subjects ($23.33{\pm}1.78$ of age, 60 eyes) in two room conditions, 760 lx and 2 lx, respectively. Pupillary diameter was measured in two conditions and the change pattern was analyzed using a peak data of corneal topography. Results: Pupillary diameter was 3.74~4.00 mm in 760 lx and 5.52~5.90 mm in 2 lx. By comparison with refractive data in 760 lx, those data in 2 lx was changed as follows: more (-) spherical power of 17 eyes (28.3%), more (+) spherical power of 10 eyes (17.7%), more (-) cylinderical power of 17 eyes (28.8%), less (-) cylinderical power of 9 eyes (15.3%), and astigmatic axis rotation of 36 eyes (62.1%). From peak data of corneal topography, the changing pattern of two principal meridians was classified into 4 types. Conclusions: Expansion of the corneal refractive surface accompanied with pupillary dilation may be a main factor that effects the changing a values of subjective refraction because of unique corneal shape. Therefore, subjective refraction should be performed under the nearest lighting condition to a main living environment.

Study of UV-cut Effect by Luminance and Size of pupil in lens (Luminance와 동공크기 변화에 따른 렌즈에서 UV 차단효과 연구)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2001
  • We analyzed the luminance in the visual light region and the size of pupil by the luminance to estimate an UV-A line cut efficiency in the lens. The size of pupil by the luminance(L) was given by ${\Phi}=d-e{\cdot}tanh(f{\cdot}logL)$ and the transmittance efficiency value of a size of pupil was given by $T_r(r)=1-gr^2+hr^4$. We derived the absolute cut efficiency value ${\alpha}$ and the exclusion index $b=(1-{\alpha}){\times}100%$ about the UV-A in the $320{\sim}400nm$ regions. The ${\alpha}$ and b values were obtained respectively 0.018, 0.31, 0.273, 0.153 and 98, 69, 72, 85% of Uv-cut Lens, CR-39, red color and blue color.

  • PDF

Analysis of Variation in Pupil Size of Elementary Students on the Types of Generating Scientific Hypothesis (과학적 가설 생성 유형에 따른 초등학생의 동공크기 변화 분석)

  • Choi, Sungkyun;Shin, Donghoon
    • Journal of The Korean Association For Science Education
    • /
    • v.37 no.3
    • /
    • pp.483-492
    • /
    • 2017
  • The purpose of this study is to analyze the variation in pupil size as shown in the scientific hypothesis generation process of students in Elementary School. The subjects for research consisted of 20 fifth-year students at Seoul B elementary school who agreed to participate in the research. The task consisted of four scientific hypothesis-generating tasks. SMI's Eye Tracker(iView $X^{TM}$ RED) was used to collect eye movement data. Experiment 3.6 and BeGaze 3.6 softwares were used to plan experiment and analyzed the task performance process and eye movement data. The findings of this study are twofold. First, there were four types that generate hypothesis about the tasks. Second, in the moment of generating hypothesis, participants' pupils have grown bigger. And while thinking of generating hypothesis or elaborating hypothesis, there were no big changes. These results show the moment of generating hypothesis is affected by emotional factors besides cognitive factors.

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

A Study on Eyes Region Detection on a Mobile Phone (휴대폰에서 눈 영역 검출 연구)

  • Park, Hyun-Ae;Park, Kang-Ryoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.789-792
    • /
    • 2005
  • 최근 급격히 발전한 휴대폰은 다양한 기능을 가지고 있다. 그 중 디지털 카메라의 기능을 겸비한 휴대폰은 디지털 카메라의 판매량을 앞서고 있고, 메가픽셀의 고화소 디카폰의 개발로 대중화가 더욱 가속화되고 있다. 카메라폰을 응용한 연구분야로는 생체인식기술을 적용할 수 있으며, 본 논문은 제약이 많은 휴대폰 환경에서 홍채인식기술을 적용하기 위한 휴대폰 카메라로 취득된 얼굴영상에서의 눈 영역을 검출하는 방법을 제안한다. 얼굴영상에서 눈은 피부나 머리카락보다 빛에 대한 반사율이 높아 각막에 specular reflection이 생기게 되고, 동공은 눈의 다른 지역에 비해 흑화소가 많다는 특징을 가지고 있다. 이러한 두 가지 특징을 이용하여 동공 후보 영역을 선정하였고, 선정된 이진영상에서 수평 프로파일과 수직 프로파일을 적용하여 동공 후보 영역을 줄이면서 동공의 중심 위치를 검출한다. 본 연구는 휴대폰 환경을 고려하였기 때문에 최소한의 메모리 사용과 적은 연산량을 목표로 하여 눈의 위치를 검출 한다. 실험 결과, 입력 영상 내에 일정크기의 동공영역이 존재할 경우 높은 눈 영역 추출 성공률을 보이며, 본 연구에서 제안한 알고리즘을 실제 휴대폰에서 수행한 결과 평균571.6ms의 시간이 소요됨을 알 수 있었다.

  • PDF

DEM Simulation on the Initiation and Development of Road Subsidence (개별요소법을 활용한 도로함몰 발생과 전개거동 예측)

  • Kim, Yeonho;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.7
    • /
    • pp.43-53
    • /
    • 2017
  • Road subsidence, frequently occurring in urban areas, is caused by collapsing of surface layer due to underground cavities followed by a loss of soils. To better understand this phenomenon, the mechanism of cavity formation should be identified firstly. Two kinds of possible subsidence mechanisms were established through previous case studies and the numerical analyses based on Distinct Element Method were conducted for each of these mechanisms. It was confirmed that particle loss and surface settlement can develop differently depending on slit size, void ratio, and particle shape among the various factors influencing the road subsidence. The result demonstrated that the effects of varying cavity diameter and depth could be quantified as a damage chart.

Ocular and Facial Dimension of Primary School (초등학교 학생 눈의 외부측정)

  • Kim, Chang Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.145-148
    • /
    • 1997
  • The mersurements of the inter outer canthal distance (IOCD), inter inner canthal distance(IICD), inter temporal distance (ITD), length palpebral fissure (LPF) and inter pupilly distance(PD) were followed in 852 healthy Korean from 7 to 13 years old. The change of average dimension was 6 mm in PD and 20 mm in ITD during primary school, and then grow up to the dimension of adult. The dimension of ITD and LPF in female was larger than male from 8 to 10 years old. The dimension of LPF increased by change of IOCD more than IICD.

  • PDF

Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery (굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가)

  • Kim, Jeong-Mee;Lee, A-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.