• Title/Summary/Keyword: 동공 크기

Search Result 108, Processing Time 0.027 seconds

Comparative Study on Growth Stage Aging Changes of The Right and Left Eye Size in Korean (성장기 연령 변화에 따른 좌우안 크기 변화 비교 연구)

  • Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.209-216
    • /
    • 1998
  • The purpose of this study was to compare the right and left eye size, distance between two eyes, interpupillary distance on growth stage aging changes in Korean. The author divided into 5 groups according to subject's age(group A : 7~12 years, group B : 13~15 years, group C : 16~18 years, group D : 19~24 years, group E : 25~30 years). The high values of inter outer canthal distance(T) and distance between two eyes(G) were 94.30 mm, 36.66 mm at group B respectively. The ratio of identical eye size was about 10.0% in A, B, C group but 22.7% in E group. P[T-(right eye size + left eye size) / 2] was wider than IPD. Data showed that the difference was 5.72 mm in group B and 1.13 mm in group E. The reason for this is that the pupils are displaced nasally from the center of the limbal ring. This has significant meaning in ophthalmic procedures.

  • PDF

The effect of inter-pupillary distance on stereopsis (동공간 거리가 입체시 지각에 미치는 영향)

  • 감기택;이주환
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2003
  • Most 3D display systems heavily depend on binocular disparity to produce 3-dimensional depth of a scene. In principle, the vergence angle of the object on fixation and binocular disparity of non-fixated objects vary with the inter-pupillary distance(IPD) of the observer. However, most stereo systems provide the identical stereo image pairs regardless of the observers' IPD, which may result in variation in the perceived depth. In this study, we manipulated the vergence angle of the fixated object and binocular disparity of the non-fixated object. The range of the individual difference in the perceived depth was found to be increased with the increase of disparity for both the fixated and non-fixated objects, and the individual difference was well fitted by the regression line of the observers' IPD. These results suggest that individual difference in the perceived depth from the identical stereo images should be greatly reduced if the stereo system calibrates the disparity of the object by the observers' IPD in generating the stereo images and the regression line found in this study might be useful in the calibrating the disparity of the images.

  • PDF

Development of Videooculograph for Vestibular Function Test (전정 기능 평가를 위한 영상 안구 운동 측정 시스템의 개발)

  • 김수찬;남기창;이원선;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.189-198
    • /
    • 2003
  • Videooculography (VOG) is one of the eye-movement measurement methods used for objective evaluation of vestibule -ocular reflex. A key feature of VOG is to estimate accurately the center of pupil and ocular torsion with being less influenced by the upper eyelid droop, eyelashes, corneal reflection, and eye blinks. Especially, it Is important to find the accurate center of the pupil in 3-D VOG because the inaccurate pupil center causes significant errors on measuring torsional eye movement. A new algorithm was proposed to find the center of pupil which is a little influenced by factors mentioned above. In this study, real time three-dimensional VOG which can measure horizontal, vortical, torsional eye movements, and the diameter of pupil was implemented using the proposed method.

Plasma Dealloying 공정을 통한 Nanoporous Thin Film 제작 및 특성분석

  • Lee, Geun-Hyeok;An, Se-Hun;Jang, Seong-U;Hwang, Se-Hun;Yun, Jeong-Hyeon;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.353.1-353.1
    • /
    • 2016
  • 다공성 물질은 동공의 크기에 따라 미세동공(Micropore), 메조동공(Mesopore), 거대동공(Macropore)으로 나누어 분류한다. 다공성 재료의 장점은 높은 비표면적으로써, 촉매, 센서, 연료전지 전극, 에너지 저장장치 등으로의 이용 가능성을 보여주는 연구가 활발히 보고되고 있다. 종래의 연구는 두 가지 이상의 원소로 구성된 박막을 제작한 후 전기화학적 분해법, 선택적 용해법 등 습식공정을 통해 다공성 구조체를 제작하였다. 하지만 본 연구에서는 Au, Ag 타겟과 $CH_4$ gas를 이용해 ICP-assisted reactive magnetron sputtering 장비를 활용하여 450 nm 두께의 Au-C, Ag-C 박막을 제작하였다. 이후 연속적으로 RF 250 W를 ICP antenna 에 인가하여 $O_2$ plasma dealloying 공정을 통해 탄소(Carbon) 만을 선택적으로 제거함으로써, 건식 공정만으로 Si wafer ($10{\times}10mm^2$) 기판 위에 250 ~ 300 nm 두께의 다공성 Au, Ag 박막을 제작하였다. SEM (Scanning Electron Microscopy)를 활용하여 표면, 단면 형상을 관찰해 다공성 구조를 확인하였으며, AES (Auger Electron Spectroscopy)를 통해 plasma dealloying 전 후 박막의 조성변화를 관찰하였다. 따라서 plasma dealloying 공정으로 제작된 다공성 Au, Ag 박막은 기존의 습식 공정 대비 청결하고 신속한 공정이 가능하며 높은 재현성을 통해 위의 적용분야에 보다 쉽게 사용될 수 있을 것으로 기대된다.

  • PDF

Video Summarization Using Eye Tracking and Electroencephalogram (EEG) Data (시선추적-뇌파 기반의 비디오 요약 생성 방안 연구)

  • Kim, Hyun-Hee;Kim, Yong-Ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.56 no.1
    • /
    • pp.95-117
    • /
    • 2022
  • This study developed and evaluated audio-visual (AV) semantics-based video summarization methods using eye tracking and electroencephalography (EEG) data. For this study, twenty-seven university students participated in eye tracking and EEG experiments. The evaluation results showed that the average recall rate (0.73) of using both EEG and pupil diameter data for the construction of a video summary was higher than that (0.50) of using EEG data or that (0.68) of using pupil diameter data. In addition, this study reported that the reasons why the average recall (0.57) of the AV semantics-based personalized video summaries was lower than that (0.69) of the AV semantics-based generic video summaries. The differences and characteristics between the AV semantics-based video summarization methods and the text semantics-based video summarization methods were compared and analyzed.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.

The Study of Kinetic Visual Acuity in College Students (대학생의 동적시력에 관한 연구)

  • Shim, Moon-Sik;Kim, Sang-Hyun;Kang, Hye-Sook;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • Purpose: We were to obtain the basic data for studying kinetic visual acuity through the comparative analysis in kinetic visual acuity, visual acuity, refractive error, pupil size, and hand reaction time for college students. Methods: We had tested the kinetic visual acuity, visual acuity, refractive error and hand reaction time using the kinetic visual acuity tester (KOWA AS-4A), the hand reaction time program and auto-refractometer for thirty-nine male and same female optometry students with more than +0.1 LogMAR visual acuity in both eyes. And the results were examined gender differences of kinetic visual acuity and the factors correlation. Results: In the measured values of male, pupil size were 6.00 mm, hand reaction time 0.23 msec, refractive error -1.66 D, visual acuity -0.07, kinetic visual acuity 0.59 and pupil size 5.86 mm, hand reaction time 0.24 msec, refractive error -2.08 D, visual acuity -0.02, kinetic visual acuity 0.46 in female. It was significant difference for kinetic visual acuity values but other factors were not. The kinetic visual acuity and left visual acuity had the highest correlation, r=-0.406. The kinetic visual acuity indicated more excellent values in the case of increasing visual acuity and decreasing myopia amount. Conclusions: It was able to see that male college students were better than female for kinetic visual acuity and the visual acuity were related to kinetic visual acuity.

Study on Development of Infrared Retinoscope (적외선 검영기의 개발에 관한 연구)

  • Lee, Ik-Han;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 2004
  • The aim of this thesis research is to develop equipment measuring refractive state in order to measure the general ocular function using PC-based Foucault Test(Knife Edge Test). The Image of light generated from the reflection of incident light in retina thru Knife Edge Test was photographed using a CCD camera. The resulting image was then analyzed to measure the size of pupil by measuring the diameter of reflected image. The reflection state was judged from the orientation of reflected image and the degree of abnormal reflection was confirmed by measuring the size of second image of reflection. The aberration value was calculated from the magnitude of spherical aberration obtained by comparing the brightness of second reflected image appeared in the opposite direction to the reflected image.

  • PDF

Realistic Expression Factors According to Visual Presence in Terms of Iris color and Pupil Accommodation of Virtual Avatar (가상 아바타의 홍채색과 동공 조절에 따른 시각적 실재감에 대한 실감표현요소)

  • Won, Myoung Ju;Park, Sang-In;Lee, Eui Chul;Whang, Min-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • The virtual avatar is a principal way as media for communicating language and affective feelings in virtual environment. As similar purpose, this study evaluates user's visual feeling according to the changes of iris color and pupil size of virtual avatar which is considered as new factors for representing realistic avatar. Virtual avatars were configured by pupil accommodation and iris color(green, brown). After presenting above image to 32 participants, a questionnaire(18 items) based on previous studies was created, and reported as a 5-point scale. Experimental result showed that the case of adopting pupil accommodation induced more realistic visual feeling of subjects. This result can be regarded as a basis for designing realistic virtual avatar by confirming the effectiveness of pupil accommodation of avatar in terms of representing visual presence.

Concealed information test using ERPs and pupillary responses (ERP와 동공 반응을 이용한 숨긴정보검사)

  • Eom, Jin-Sup;Park, Kwang-Bai;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.259-268
    • /
    • 2012
  • In a P300-based concealed information test (P300 CIT), the result of the test is greatly affected by the value of the probe stimulus. With a probe stimulus of low value, the detection rate decreases. The aim of this study was to determine whether the pupil-based concealed information test (Pupil CIT) could be used in addition to the P300 CIT for the probes of low value. Participants were told to choose one card from a deck of five cards (space 2, 3, 4, 5, 6), Then a P300 CIT and a Pupil CIT for the selected card were administered. P300s were measured at 3 scalp sites (Fz, Cz, and Pz), and the pupil sizes of left and right eyes were recorded. The P300 amplitude measured at Fz, Cz, and Pz was significantly different between the probe and irrelevant stimuli. And, in the Pupil CIT, the pupil size was also different between the two stimuli for both eyes. The detection rates of the P300 CIT were 44% at Fz and Cz sites and 36% at Pz site. And the detection rates of the Pupil CIT were 52% for the left eye and 60% for the right eye. There is a trend that the detection rate of the Pupil CIT was higher than that of the P300 CIT, but the difference didn't reach significance partly because of the relatively small sample size. The correlation between the decision based on the P300 CIT and that based on the Pupil CIT was not significant. As a conclusion, it is recommended to use a Pupil CIT instead of a P300 CIT when the value of the probe is low. And a combination of the measures may be superior to either one of them in detection rate.

  • PDF