• 제목/요약/키워드: 돌입전류

검색결과 82건 처리시간 0.035초

자속-전류비율곡선을 이용한 전력용 변압기의 여자돌입검출 (Inrush Current Detection of Power Transformer using Flux-current Derivative Curve)

  • 김수경;박철원;신명철;서희석;장병태;김일동;김영한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.186-189
    • /
    • 1996
  • Convential inrush current detection method is used to harmonic restraint method by filtered second frequency component. Nowadays this technique must be modified because harmonics are occurred in steady state of power system. A purpose of this study is to develop of inrush current detection relaying algorithm for power transformer based on flux-current derivative curve method. We used the relaying signals obtained from EMTP simulation.

  • PDF

주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발 (A Development of Intelligent Controller for Phase Control in Main Circuit Breaker)

  • 오용국;김재원;류준형
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.755-761
    • /
    • 2017
  • 교류 철도차량에 사용되는 주회로차단기 (Main Circuit Breaker)는 전차선 전원을 차량 내 투입 또는 차단하는 기능을 한다. 일반적으로 주회로차단기는 판토그라프와 주변압기 사이에 위치하며, 주회로차단기의 동작시점에 따라 차량에 투입되는 전원의 위상이 변화하게 된다. 투입전원의 위상에 따라 차량 내 돌입전류, 서지전압 등의 형태로 차량 전기장치 내 의도하지 않은 과도현상이 야기될 수 있으므로, 주회로차단기의 동작은 전차선 전원의 위상각에 따라 능동적으로 제어되어야 한다. 하지만 주회로차단기는 동작신호 인가 이후, 실제 개폐 동작 시까지 일정하지 않은 동작지연시간이 존재한다. 따라서 동작 지연시간을 예측하고, 이를 고려하여 주회로차단기를 개폐시점을 제어하는 지능형 제어기가 필요하다. 본 논문에서는 주회로차단기의 투입전원 위상 제어를 위하여 동작 메카니즘 및 동작 지연요소를 분석하였다. 그리고 차단기 및 구성품 별 반복동작시험을 통하여 동작 지연시간을 분석하고, 이를 예측하기 위한 이동평균 (Moving Average) 알고리즘을 제안하였다. 또한 지능형 제어기 개발 및 제작을 통하여 제안된 알고리즘을 구현하였으며, 주회로차단기와의 연동시험을 통하여 알고리즘의 성능을 검증하였다.

돌입전류 제한용 $Mn_3$$O_4$-NiO-CuO-$Co_3$$O_4$-ZnO계 NTC 써미스터에서 ZnO/$Mn_3$$O_4$비에 따른 전기적 특성 (Electrical Properties as the ratio of ZnO/$Mn_3$$O_4$ of NTC Thermistor with $Mn_3$$O_4$-NiO-CuO-$Co_3$$O_4$-ZnO system for Inrush Current Limited)

  • 윤중락;김지균;권정렬;이현용;이석원
    • 한국전기전자재료학회논문지
    • /
    • 제13권6호
    • /
    • pp.472-477
    • /
    • 2000
  • Oxides of the form Mn$_{4}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO present properties that make them useful as power NTC thermistor for current limited. Electrical properties of Mn$_{3}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO power NTC thermistor such as I-V characteristics tim constant activation energy and heat dissipation coefficient measured as a function of temperature and composition. In Mn$_{4}$/O$_{4}$-CuO-Co$_{3}$/O$_{4}$-NiO-ZnO system with the 5wt% addition of Co$_{3}$/O$_{4}$ it can be seen that resistivity and B-constant were increased as the ratio of ZnO/Mn$_{3}$/O$_{4}$ was increased. Heat dissipation constant, I-V characteristics and time constant showed similar behaviour compared with those of conventional thermistors. In particular resistance change ratio ($\Delta$R) the important factor for reliability varied within $\pm$5% indicating the compositions of these products could be available for power thermistor.

  • PDF

전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구 (A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway)

  • 허재선;강병욱;신희상;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

초전도 한류기 투입저항 변화에 따른 여자돌입전류 저감률 분석 (Analysis of Inrush Current Reduction Rate According to Insertion Resistance of the Superconducting Fault Current Limiter)

  • 박세호;서훈철;이상봉;김철환;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.257-258
    • /
    • 2008
  • The inrush current of a transformer is a high-magnitude and harmonic-rich current generated when the transformer core is driven into saturation during energizing. The inrush current usually leads to undesirable effects, for example potential damage to the transformer, misoperation of a protective relay, and power quality deterioration in the distribution power system. Inrush current reduction is therefore important for power system operation. In this paper, to reduce the inrush current, the insertion resistance of the Superconducting Fault Current Limiter (SFCL) that is connected in series with the transformer in the distribution system is used. This paper implements the SFCL by using the Electromagnetic Transient Program-Restructured Version (EMTP-RV) to model the SFCL in the distribution system. The simulation results show the beneficial effects of the SFCL for reduction of the inrush current.

  • PDF

단상유도전동기의 돌입전류저감을 위한 제어기 설계 (Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor)

  • 박수강;백형래;이상일
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

스위치 저감형 Z-Source Inverter PWM 제어 (PWM Control of Reduced Switch Z-Source Inverter)

  • 김성환;박태식
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.53-57
    • /
    • 2019
  • 본 논문에서는 스위칭 소자를 줄이기 위한 새로운 Z-소스 인버터의 구조와 PWM 펄스 제어 방법에 대하여 제안하였다. 개선된 Z-소스 인버터는 Z-네트워크가 DC전압과 인버터 사이가 아닌 인버터 뒷단과 접지 사이에 연결되며, 이러한 개선된 Z-소스 인버터는 커패시터 돌입 전류 제한 기능과 커패시터 전압 스트레스가 작은 장점을 가지고 있다. 개선된 Z-소스 인버터에서 스위치를 6개에서 4개로 줄이는 새로운 형태의 스위치 저감형 Z-소스 인버터의 Topology를 제안하고, 제안된 Topology에 적합한 PWM 제어 방법을 개발하였다. 제안된 방법은 PSIM 시뮬레이션을 통해 특성과 성능을 확인하였다.

대용량 유도기 기동 특성 모델링 및 전략적 기동 방법에 관한 연구 (Modeling and Strategic Startup Scheme for Large-Scaled Induction Motors)

  • 정원욱;신동열;이학주;윤기갑
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.748-757
    • /
    • 2007
  • 본 논문은 대용량 유도전동기가 기동할 때 발생하는 큰 돌입전류로 인해 PCC(Point of Common Coupling)에 심한 전압 강하가 발생하게 되어 기동에 실패하는 문제를 해결하기 위해 대상 유도전동기의 기동 특성과 배전계통을 모델링하고 시뮬레이션을 수행함으로써 유도기 기동시에 전압저하 현상을 해석하였다. 문제가 되는 유도전동기는 2500KVA 용량의 펌프용 농형 유도전동기로 리액터 기동법을 채용하고 있다. 2500KVA 유도전동기 한대의 기동에는 문제가 없으나 기동 완료 후 PCC 전압이 다소 떨어진다. 하지만 추가로 동일 용량의 유도전동기가 기동하게 되면 PCC의 심한 전압강하로 기동에 실패하게 되는 문제가 발생하였다. 이러한 문제 해결을 위해 본 논문에서는 실제 기기의 기동시 토크-속도 곡선을 이용한 유도전동기의 기동 특성을 정확히 모델링하고 시뮬레이션을 수행하여 두 대의 대용량 유도전동기가 순차적으로 기동에 성공할 수 있는 적절한 전압보상 방안을 제안하였다. 본 논문에서 논의되는 대용량 유도전동기는 한국수자원공사의 취수장에서 운전되고 있으며 대상 유도전동기 및 배전계통은 PSCAD/EMTDC 소프트웨어를 사용하여 모델링 및 시뮬레이션을 수행하였다.

  • PDF

NBTI 노화 효과를 고려한 헤더 기반의 파워게이팅 구조 (Header-Based Power Gating Structure Considering NBTI Aging Effect)

  • 김경기
    • 대한전자공학회논문지SD
    • /
    • 제49권2호
    • /
    • pp.23-30
    • /
    • 2012
  • 본 논문에서는 음 바이어스 온도 불안정성 (NBTI) 효과에 의해서 야기되는 파워 게이팅 구조의 성능 저하와 증가하는 기상시간을 보상하기위한 새로운 적응형 헤더기반의 파워 게이팅 구조를 제안한다. 제안된 구조는 두 개의 패스 (two-pass)를 가지는 파워 게이팅 구조에 기반을 둔 폭 변화 헤더(header)와 적응형 제어를 위한 새로운 NBTI 센싱 회로로 구성된다. 본 논문의 시뮬레이션 결과는 적응형 제어를 하지 않는 파워 게이팅의 시뮬레이션 결과와 비교되며, 그 결과는 파워 게이팅 구조에서 누설 전력과 돌입 전류(rush current)을 작게 유지하면서 회로 지연과 기상시간에 대한 NBTI 의존성이 단지 3% 와 4% 내로 줄어든다는 것을 보여준다. 본 논문에서는 45nm CMOS 공정과 NBTI 예측 모델이 제안된 회로를 구성하기 위해서 사용된다.

농업용 전기차량의 전기식 동력인출장치용 전력변환시스템 (Power Conversion System for Electric Power Take-off of Agricultural Electric Vehicle)

  • 곽봉우;김종훈
    • 전기전자학회논문지
    • /
    • 제23권3호
    • /
    • pp.994-1002
    • /
    • 2019
  • 본 논문은 농업용 전기차량의 전기식 동력인출장치용 전력변환시스템에 대해 제안한다. 대부분의 전기식 동력인출장치(Electric Power Take-Off : e-PTO)는 상용전원 $220V_{AC}$를 사용한다. 농업용 전기차량의 낮은 배터리 전압을 사용하여 높은 출력 전압을 공급하기 위한 DC-DC 컨버터와 DC-AC 인버터로 구성된 2단 구조를 갖는 양방향 전력변환시스템이 적합하다. 제안하는 전력변환시스템은 1단의 Dual Active Bridge(DAB)컨버터와 2단의 양방향 풀 브릿지 인버터로 구성된다. 또한, 초기 구동시 DC 버스단 커패시터 충전에 의해 발생되는 돌입 전류 저감을 위해 소프트 스타트 알고리즘을 제안한다. 3kW급 전력변환시스템 시제품 및 알고리즘을 구현하고 실험을 통해서 실용성을 입증하였다.