• Title/Summary/Keyword: 도플러 초음파

Search Result 184, Processing Time 0.031 seconds

Incidence of Deep Vein Thrombosis before Hip Fracture Surgery Diagnosed by Color Doppler Sonography Surveillance (고관절 주위 골절환자에서 술 전 색 도플러 초음파를 이용하여 진단한 심부 정맥 혈전의 빈도)

  • Jung, Jae-Hoon;Lee, Kyung-Jae;Min, Byung-Woo;Son, Eun-Seok;Koo, Tae-Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Purpose: To evaluate the incidence of deep vein thrombosis (DVT) before hip fracture by duplex color Doppler ultrasonography. Materials and Methods: From June 2013 to May 2014, 27 patients who had agreed to perform color Doppler ultrasonography before hip fracture surgery were evaluated for the incidence of DVT. Patients who had history of DVT were excluded. Five patients were men and 19 patients were women. The mean age was 74.3 years old (41-87). There were 15 cases of femoral neck fracture, 11 cases of intertrochanteric fractures and one case of acetabular fracture. Surgical intervention underwent within 48 hours from admission and duplex color Doppler ultrasonography was carried out at the day of admission. Results: DVT occurred in six cases (22.2%). Four cases (14.8%) occurred in proximal deep vein and two cases (7.4%) occurred in distal deep vein. The mean period of immobilization was longer in patients who had DVT. But there was no significant difference. The mean age was 79 years old (75-87) in patients who had DVT and 72 years old (65-86) in patients who had not. There was significant difference (p=0.038). Conclusion: The incidence of DVT which was diagnosed by duplex color Doppler ultrasonography before hip fracture surgery was relatively high (22.2%). So it is necessary to undergo duplex color Doppler ultrasonography more aggressively to rule out DVT before hip fracture surgery.

  • PDF

Development of an Janus-type Ultrasonic Transducer for Underwater Doppler Log Applications (수중 도플러 로그용 야누스형 초음파 트랜스듀서 개발)

  • 이수성;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.77-84
    • /
    • 2000
  • In measurement of ship speed with a Doppler log sensor, we encounter the nonhorizontal movement of a ship, i.e. pitching and rolling, and that causes inaccuracy of the measurement. In this study, we develop a Janus type ultrasonic transducer that can resolve the problems in accuracy due to the pitching and other environmental factors of common ultrasonic sensors attributed to the underwater usage. For the development, we analyze the operation mechanism of the transducer, fabricate a prototype of the sensor, and evaluate its performance through experiments.

  • PDF

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.

An Underwater Acoustic Transducer Responding to Frequency Shift by Doppler Effect (도플러효과에 의한 주파수 변화에 대응하는 수중 초음파변환자의 제안)

  • Kim, Jung-Whan;Kim, Moo-Joon;Ha, Kang-Lyeol
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.16-23
    • /
    • 1999
  • When a moving piezoelectric transducer detects an object in water, its receiving sensitivity is attenuated by Doppler effect. In this paper, a method for compensating the effect is suggested by using a newly designed condenser of which capacitance is varied according to the moving speed of the transducer. Using the method, the receiving resonant frequency of the transducer can be changed automatically. As a result, there is good agreement between the results of experiment and those of calculation. It is confirmed that the response sensitivity degradation of transducers due to Doppler effect can be compensated in the range of $1{\sim}10^m/_s$ moving speed.

  • PDF

Characterization of Twinkling Artifact in differently Colored Urinary Stones in Color Doppler Ultrasound: an In-vitro Study (색이 다른 요로결석에서 칼라도플러 초음파의 트윈클링허상의 특성: 체외 연구)

  • Hye-Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1049-1055
    • /
    • 2023
  • The purpose of this study was to investigate the association of twinkling artifacts according to the types of urinary stones in color Doppler ultrasound. For two types of urinary stones with different colors, the degree of occurrence of color Doppler twinkling artifact in water tank was analyzed, and the surface condition and composition of the stones were analyzed. The composition of Calcium and phosphorus were the most frequent components in white and brown stones excluding carbon and oxygen. Twinkling artifacts of color Doppler appear stronger in brown stone. The higher the phosphorus content of the stones, the shorter the twinkling artifact appears, so it is possible to predict the main composition of stones.

Automatic speech recognition using acoustic doppler signal (초음파 도플러를 이용한 음성 인식)

  • Lee, Ki-Seung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.1
    • /
    • pp.74-82
    • /
    • 2016
  • In this paper, a new automatic speech recognition (ASR) was proposed where ultrasonic doppler signals were used, instead of conventional speech signals. The proposed method has the advantages over the conventional speech/non-speech-based ASR including robustness against acoustic noises and user comfortability associated with usage of the non-contact sensor. In the method proposed herein, 40 kHz ultrasonic signal was radiated toward to the mouth and the reflected ultrasonic signals were then received. Frequency shift caused by the doppler effects was used to implement ASR. The proposed method employed multi-channel ultrasonic signals acquired from the various locations, which is different from the previous method where single channel ultrasonic signal was employed. The PCA(Principal Component Analysis) coefficients were used as the features of ASR in which hidden markov model (HMM) with left-right model was adopted. To verify the feasibility of the proposed ASR, the speech recognition experiment was carried out the 60 Korean isolated words obtained from the six speakers. Moreover, the experiment results showed that the overall word recognition rates were comparable with the conventional speech-based ASR methods and the performance of the proposed method was superior to the conventional signal channel ASR method. Especially, the average recognition rate of 90 % was maintained under the noise environments.

A New Method for Extending Doppler Mean Frequency in Ultrasonic Imaging Systems (초음파 영상 시스템에서 새로운 도플러 평균주파수 확장 방법)

  • Kwon, Sung-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1047-1056
    • /
    • 2007
  • Basically, an ultrasonic imaging system has two fundamental imaging modes available. One is the B-mode imaging modality which provides an image of reflection coefficient, and the other is the Doppler color flow mode that maps blood flow inside the human heart and blood vessels. This paper presents a new method of detecting and compensating for aliasing that occurs when the Doppler frequency exceeds one-half of the pulse-repetition frequency (PRF). Its validity is shown by computer simulation. The new method not only extends the measurable Doppler frequency, but also helps to reduce the effect of noise. The results show that the aliasing can be compensated for correctly fur signal-to-noise ratios down to 20 dB.

  • PDF

Development of real-time continuous suspended sediment concentration measurement system using acoustic backscatter of H-ADCP (실시간 부유사농도 측정을 위한 횡방향 초음파도플러유속계의 초음파산란도를 활용한 부유사농도 측정 시스템 개발)

  • Son, Geunsoo;Roh, Youngsin;Kim, Dongsu;Choi, Kwangtae;Chung, Hokun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.23-23
    • /
    • 2022
  • 하천의 유량 및 유사량 자료는 하천에서 발생하는 다양한 문제를 분석하기 위한 기초자료로 지속적인 모니터링을 통한 측정자료의 생산이 필요하다. 따라서, 국내에서는 지속적인 유량 측정을 목적으로 전국의 주요 국가하천을 대상으로 약 62개소에서 H-ADCP를 활용하여 지속적인 유량측정을 수행하고 있다. 이때, H-ADCP는 유량을 측정하기 위한 유속자료와 함께 초음파산란도 자료를 부가적으로 제공하고 있어 초음파산란도를 부유사농도의 지표로 활용하여 지속적인 부유사농도를 측정하기 위한 연구가 수행되고 있으며, 기존에 설치된 자동유량관측소의 H-ADCP를 통해서 실시간의 유량자료와 함께 유사량 자료를 제공할 수 있을 것으로 기대되고 있다. 이에 본 연구에서는 자동유량관측소를 대상으로 과거 유사량 측정을 수행한 5개 지점을 선정하여 초음파산란도를 활용한 부유사농도 측정 기술의 적용성을 검토하였고, 이를 통해 제시한 부유사농도 측정 방법을 통해 실시간 부유사농도 측정 시스템을 개발하였다. 그리고 실시간 부유사농도 측정 시스템의 적용성을 검토하기 위해 나주시(남평교) 자동유량관측소 지점에 시스템을 구축하여 초음파기반의 부유사농도 측정 기술을 통한 실시간 부유사농도 산정 방법에 대한 보완 사항과 개선방향을 도출하고자 하였다.

  • PDF

Extraction of Blood Velocity Using FCM and Fuzzy Decision Trees in Doppler Ultrasound Images of Brachial Artery (상완동맥 색조 도플러 초음파 영상에서 FCM과 퍼지 의사 결정 트리를 이용한 혈류 속도 추출)

  • Kim, Kwang Baek;Jung, Young Jin;Nam, Youn Man;Lee, Jae Yeol
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.19-22
    • /
    • 2019
  • 상완동맥은 어깨에서부터 팔꿈치까지 내려오는 상완골의 내측부에 존재하며 혈압을 측정할 때 사용되는 혈관이다. 이 혈관은 골절로 인해 찢어지거나, 또는 혈액순환에 문제가 생겨 혈관이 막히는 경우가 발생한다. 이러한 경우 혈관의 상태를 확인하기 위하여 색조 도플러 초음파 검사를 사용하지만, 사용자에 따라 영상을 통한 판단 기준이 다르다는 문제점이 발생한다. 따라서 본 논문에서는 FCM과 Fuzzy Decision Tree를 이용한 영상 처리를 통해 일관성 있는 판단기준을 세우기 위한 혈류의 속도를 제안한다. 색조 도플러 초음파 영상에서의 상완 동맥을 추출하여 기울기를 이용한 FCM 알고리즘을 통해 소속도를 추출한 뒤 퍼지 룰에 적용하여 의사 결정 트리로 등급을 분류하고 결과적으로 혈류 속도를 추출한다. 색조 도플러 초음파 영상에서 환자의 개인 정보를 보호하기 위해 개인 정보 영역을 제거하여 ROI 영역을 추출하고 ROI 영역을 이진화를 통하여 상완동맥이 있는 영역을 추출한다. 이진화 된 ROI 영역에서 혈관 영상의 혈류 방향으로의 무게중심을 설정하고 각각의 픽셀과 무게중심 선과의 거리를 이용하여 소속도를 추출한 후 FCM을 사용하여 최적의 기울기를 선정한다. FCM을 통해 추출한 최종 소속도를 이용하여 퍼지 룰에 적용한 뒤 계산된 T-norm과 소속도의 분산을 이용하여 의사 결정 트리를 형성 트리의 단말 노드들은 각 픽셀을 분류한다. 분류되어진 데이터들의 노드별 소속도 평균을 구한 뒤 디퍼지화를 통해 COG(Center of Gravity)를 계산한다. 마지막으로 그 값을 이용하여 혈류 속도에 영향을 미치는 정도를 계산한 뒤 최종 혈류의 속도를 제안한다.

  • PDF