• Title/Summary/Keyword: 도플러 영상

Search Result 108, Processing Time 0.027 seconds

Concurrent Medullary Carcinoma and Hashimoto's Thyroiditis: A Case Report with an Emphasis on US Features (하시모토 갑상선염과 동반된 갑상선 수질암의 증례 보고: 초음파 소견을 중심으로)

  • Hyoung Yeob Kim;Noh Hyuck Park
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1146-1151
    • /
    • 2023
  • Medullary thyroid carcinoma (MTC) is a rare malignancy that originates from the parafollicular cells of the thyroid gland. Hashimoto's thyroiditis (HT) is an autoimmune thyroid disease and is the most common cause of hypothyroidism. Previous studies have frequently discussed the association among HT, papillary thyroid carcinoma, and thyroid lymphoma. However, there have been few reports on the ultrasonographic findings of concomitant HT and MTC. In the present case, a heterogeneous hypoechoic background parenchymal echogenicity, with intraglandular echogenic strands, and increased vascularity were observed. A concurrent, ill-defined, parallel-oriented, heterogeneous hypoechoic mass with central microcalcifications was located at the left thyroid gland, consistent with reported US findings of medullary thyroid carcinoma except for an ill-defined margin in our case.

레이다와 전파신호처리 기술(I)

  • 곽영길
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.1
    • /
    • pp.100-110
    • /
    • 1994
  • 레이다 신호는 대표적인 전자파 신호로서 주변환경에 따라 시간, 주파수, 공간 영역에서 고유한 신호특성을 가지고 있으며, 신호처리 기법도 다양하다. 본 논문에서는 먼저 레이다를 위한 전파 신호처리 의정의와 필요성을 언급한뒤, 레이다 신호환경 특성을 살펴보고 신호처리를 위한 신호의 시간 및 스펙트럼 특성에 대해 기술하였다. 그리고, 신호특성에 적합한 신호처리기의 구현을 위해 레이다 신호처리에 관 련된 주요 기법에 대해 개괄적으로 설명하였다. 레이다 신호처리 분야는 일반적으로 잘 알려진 음성이 나 영상신호처리 분야와 달리 고유한 알고리듬과 구조가 요구된다. 신호처리기법으로서 레이다 파형설 계, 해상도 모호성, 펄스압축, 클러터제거, 도플러처리, 일정오경보탐지, 클러터 지도, 표적군 형성/ 추출, 표적식별, 레이다영상기법, 적응배열처리 등에 관해 개괄적으로 설명하였다. 레이다 선호처리 기술은 "스마트"한 레이다를 위한 두뇌 역할을 하기때문에 그 필요성과 중요성이 증가하고 있다. 그러나, 고속, 대용량의 신호를 주어진 빔 주사시간동안에 실시간으로 처리하여 표적 정보를 추출해야 하기 때문에 아직도 상용 프로세서의 속도 한계내에서 알고리듬의 수행에 다소 제약을 받고 있으나, 최근 디지탈 신호처리 전용의 고속 칩의 출현으로 많은 발전을 가져오고 있다. 끝으로, 향후 레이다 신호처리 발전 추세와 응용분야에 대해 살펴보았다. 응용분야는 군수 및 민수용의 겸용 파급효과가 매우 크고, 군용의 대공탐색 및 조기경보, 전장감시뿐만 아니라 전투기 탑재용으로 필수적이며, 특히 민수용의 공 항, 항공기, 선박, 위성 등 매우 다양하다. 최근 발전추세에 따른 기술로서 다중모드 신호처리, 고집적 회로기술, 적응배열, 디지탈 빔형성, 적응성, 고분해능 및 방향성, 표적식별, 다차원 신호처리에 대해 언급 하였다.

  • PDF

Echocardiographic Diagnosis of Mitral Valve Dysplasia Concurrent with Mitral Stenosis and Tricuspid Valve Dysplasia in a Dog (개에서 승모판 이형성증과 병발한 승모판 협착증 및 삼첨판 이형성증의 심초음파적 특징 1례)

  • Choi, Soo-Young;Lee, Jung-Woo;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.101-104
    • /
    • 2015
  • A 4-years-old, intact male Golden retriever dog was presented with abdominal distension and dyspnea. Physical examination revealed arrhythmia and cardiac murmur. Generalized cardiomegaly, pleural effusion and ascites were shown on thoracic and abdominal radiographs. Two-dimensional echocardiography revealed abnormal mitral and tricuspid valve motion, mitral and tricuspid regurgitation, left ventricular eccentric hypertrophy and left atrial dilation. Color-flow Doppler imaging revealed turbulent flow extending into the left ventricle during diastole from the mitral valve orifice, and into the left atrium during systole. Spectral Doppler recordings revealed highly increased early diastolic mitral valve inflow and prolonged pressure half-time of mitral inflow. Based on the echocardiographic examination, the diagnosis was made as the mitral valve dysplasia concurrent with mitral valve stenosis and tricuspid valve dysplasia.

Power Doppler Sonography for the Upper Urinary Tract Infection in Children (소아 상부요로감염의 진단을 위한 출력 도풀러 초음파조영술)

  • Choi, Jung-Youn;Cho, Jae-Ho;Park, Yong-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.179-185
    • /
    • 2007
  • Backgroud : Urinary tract infection (UTI) is common in children. The available gold standard methods for diagnosis, Tc-99m dimercaptosuccinic acid (DMSA) scan and computed tomography (CT) are invasive and expensive. This study was performed to assess the role of power Doppler ultrasound (PDU) for diagnosis of acute pyelonephritis (APN). Materials and Methods : A prospective study was conducted in 25 children with aged 2 weeks to 5 years who were hospitalized with the first episode of febrile UTI suggesting acute pyelonephritis. All children were examined in the first 3-5 days of admission by PDU and Tc-99m DMSA scan. The comparison between PDU and DMSA scan was performed on the basis of patients. Results : The sensitivity and specificity of PDU for the detection of affected kidneys were 38.1% and 50.0%, and the positive predictive value and negative predictive value were 61.9% and 50.0%, respectively. Vesicoureteral refluxes (VUR) were identified in 11 patients (44.4%) and 18 kidneys (36%). The PDU and DMSA scan showed a matching perfusion defect in 23.8% and 50.0% respectively. Conclusion : These data indicate the PDU has a relatively low sensitivity and specificity for differentiating APN from lower UTI but may be a complement tool to DMSA scan for the prediction of VUR in infants and children.

  • PDF

Doppler Velocity-based Dynamic Object Tracking and Rejection for Increasing Reliability of Radar Ego-Motion Estimation (레이더 에고 모션 추정 신뢰성 향상을 위한 도플러 속도 기반 동적 물체 추적 및 제거)

  • Park, Yeong Sang;Min, Kyoung-Wook;Choi, Jeong Dan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.5
    • /
    • pp.218-232
    • /
    • 2022
  • Researches are underway to use a radar sensor, a sensor used for object recognition in vehicles, for position estimation. In particular, a method of classifying dynamic and static objects using the Doppler velocity, the output from the radar sensor, and calculating ego-motion using only static objects has been researched recently. Also, for the existing dynamic object classification, several methods using RANSAC or robust filtering has been proposed. Still, a classification method with higher performance is needed due to the nature of the position estimation, in which even a single failure causes large effects. Hence, in this paper, we propose a method to improve the classification performance compared to existing methods through tracking and filtering of dynamic objects. Additionally, the method used a GMPHD filter to maximize tracking performance. In effect, the method showed higher performance in terms of classification accuracy compared to existing methods, and especially shows that the failure of the RANSAC could be prevented.

A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation (Azimuth Stitching 없는 ScanSAR 영상화: 시간영역 교차상관)

  • Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.251-263
    • /
    • 2022
  • This paper presents an idea of ScanSAR image formation. For image formation of ScanSAR that utilizes the burst mode for raw signal acquisition, most conventional single burst methods essentially require a step of azimuth stitching which contributes to radiometric and phase distortions to some extent. Time-domain cross correlation could replace SPECAN which is most popularly used for ScanSAR processing. The core idea of the proposed method is that it is possible to relieve the necessity of azimuth stitching by an extension of Doppler bandwidth of the reference function to the burst cycle period. Performance of the proposed method was evaluated by applying it to the raw signals acquired by a spaceborne SAR system, and results satisfied all image quality requirements including 3 dB width, peak-to-sidelobe ratio (PSLR), compression ratio,speckle noise, etc. Image quality of ScanSAR is inferior to that of Stripmap in all aspects. However, it is also possible to improve the quality of ScanSAR image competitive to that of Stripmap if focused on a certain parameter while reduced qualities of other parameters. Thus, it is necessary for a ScanSAR processor to offer a great degree of flexibility complying with different requirements for different applications and techniques.

Synthetic Aperture Radar Target Detection Using Multi-Cell Averaging CFAR Scheme (다중 셀 평균 기반 CFAR 검출을 이용한 SAR 영상 표적 탐지 기법)

  • Song, Woo-Young;Rho, Soo-Hyun;Jung, Chul-Ho;Kwag, Young-Kil
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.164-169
    • /
    • 2010
  • Since the range and Doppler resolution of the synthetic aperture radar(SAR) image becomes very high, the target detection accuracy can be significantly increased, but the computational burden is also increased. The conventional single-cell based CFAR detector performs the target detection on every single cell basis, thus it causes the serious increment of the computational load. In this paper, the improved two-step MCA-CFAR detector is proposed for the improvement of the target detection as well as the reduction of computational load: the first step is to use the MCA-CFAR, and the second step is to use the single-cell based CFAR detection in the expected target area for final decision. The performance of the proposed algorithm is compared with the conventional single-cell based CFAR and MCA-CFAR on SAR images.

An Efficient Motion Estimation and Compensation Method for Ultrasound Synthetic Aperture Imaging (초음파 합성구경 영상을 위한 효율적인 움직임 추정 및 보상 기법)

  • 김강식;황재섭;정종섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.87-99
    • /
    • 2002
  • This paper describes a method for overcoming the motion artifacts inherent in synthetic aperture(SA) imaging. based on the investigation results as to the influence of a target motion on synthetic aperture techniques. This method uses a region-based motion compensation approach in which only the axial motion is estimated and compensated for a given region of interest(ROI) under the assumption that the whole ROI moves uniformly The estimated axial motion is calculated with a crosscorrelation(CC) method at the Point where the focused signal has the maximum energy within the ROI. We also presents a method for estimating the axial motion using the autocorrelation(AC) method that is widely used to estimate average Doppler frequency Both computer simulations and in vivo experiments show that the proposed methods can improve greatly the spatial resolution and SNR of ultrasound imaging by implementing the SA techniques for two-way dynamic focusing without motion artifacts. In addition the AC-barred motion compensation method provides almost the same results as the CC-based one, but with a dramatically reduced computational complexity.

Effect of turbulent motions within the boundary layer on the sediment transport based on the three-dimensional particle image velocimetry (3차원 입자 영상 유속계를 기반으로 한 경계층 내 난류 흐름이 유사에 미치는 영향에 대한 연구)

  • Park, Hyungchul;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.24-24
    • /
    • 2021
  • 자연하천 바닥 경계층 내에서는 복잡한 난류 구조가 형성되며 이들은 하상에 강한 모멘텀을 전달한다. 바닥 부근에 분포하는 유사 입자들은 경계층 내에서 발생한 난류 흐름으로부터 모멘텀을 전달받아 소류사 혹은 부유사 형태로 이송되게 되며, 이러한 유사 이송 과정을 역학적으로 설명하기 위해서는 경계층 내 유체 흐름에 대한 이해가 선행되어야한다. 경계층 내 난류 흐름 특성이 유사 입자의 움직임에 미치는 영향에 대해 분석하기 위해서는 바닥 경계층 내 고해상도 유속 자료와 유사 움직임을 동시에 포착할 수 있는 기술이 요구된다. 하지만 현재까지 수행된 대부분의 선행 연구들은 점 유속을 측정할 수 있는 음파 도플러 유속계 (Acoustic Doppler Velocimetry) 혹은 2차원 입자 영상 유속계를 활용하였으며, 이들은 복잡한 3차원 난류 흐름 특성을 분석하기에는 한계가 있다. 본 연구의 목적은 실험실 실험을 통해 바닥 경계층 내 3차원 난류 흐름이 유사 이송에 미치는 영향에 대해 조사하는 것이다. 본 연구에서는 유사 주변에서의 고해상도 3차원 흐름 유동장 및 순간적인 유사 움직임에 대해서는 합성 개구 (synthetic aperture) 기반의 3차원 입자 영상 유속계 및 입자 추적 유속계를 활용하여 취득하였다. 취득된 흐름 유동장을 기반으로 레이놀즈 전단응력을 산정하였으며 이를 통해 유체가 하상에 미치는 모멘텀의 크기를 파악하였다. 복잡한 난류 흐름 구조에 대해서는 팔분원 분석 (octant analysis)을 통해 구분했으며, 유사가 움직이는 순간의 유속장을 기반으로 유사 이송을 발생시키는 지배적인 난류 흐름 특성에 대해 규명하였다. 본 연구는 바닥 경계층 내 복잡한 3차원 난류 흐름과 유사 입자의 움직임을 동시에 분석함으로써 기존에 수행되어왔던 선행 연구들의 한계점을 극복하고 보다 명확한 유사 이송의 발생 원인에 대해 분석했다는 점에 의의가 있다.

  • PDF

A Study on the Pulse Doppler System with M-mode Image and Spectrum Analyzer (주파수 해석기와 M-mode 영상을 갖는 펄스 도플러 장치의 개발에 관한 연구)

  • Jeong, Taek-Seob;Park, Sei-Hyun;Kim, Young-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1217-1220
    • /
    • 1987
  • We have developed a Ultra Sound Pulsed Doppler System with two-dimensional M-mode image and Spectrum analyzer. The image of the M-mode is composed of time and depth axes. The Spectrum analyzer shows the spectrum of Doppler signal which represents the velocity component of time dependent blood-flow behavior. The spectrogram using Spectrum analyzer is composed of frequency and amplitude axes. The outputs of the system are audio signals, velocity curves, velocity profiles, M-mode images and spectrogram.

  • PDF