• Title/Summary/Keyword: 도플러 속도

Search Result 294, Processing Time 0.026 seconds

LDV Measurement for the Mixing Effect of the Rotator Shape in a Confined Cylinder (밀폐된 원통내부에서 회전체의 형상에 따른 혼합효과에 대한 LDV 측정)

  • Park, Cheon-Soo;Kim, You-Gon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.720-726
    • /
    • 2001
  • Two-dimensional, angle-resolved LDV(Laser Doppler Velocimetry) measurements of the turbulent rotating flow field in a confined cylinder have been performed. The configurations of interest are flows between a rotating upper disk with a rod attached by a disk or impeller(${\theta}= 90^{\circ},\;45^{\circ}$) and a stationary lower disk in a confined cylinder. The mean flow velocity as well as the turbulent intensity of the flow field have been measured. The results show that the flow is strongly dependent on the position of the impellers or the disk, negligibly affected by the Reynolds number in turbulent flow. It is observed that the mixing effect of the axial flow impeller(${\theta}= 45^{\circ}$) is better than that of the radial flow impeller(${\theta}= 90^{\circ}$) or a disk.

  • PDF

A study on the implementation of multi-velocity log system using ultrasonic doppler effect (초음파 도플러 효과를 이용한 선박 종합 속도 측정 시스템 구현에 관한연구)

  • 류점수;신동우;민경선;김영길;강동균;임종곤
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.3
    • /
    • pp.38-46
    • /
    • 1996
  • In this paper, a multi-velocity log system which uses ultrasonic pulsed doppler signal is developed. The output of the system is the absoluted velcocity of the ship. By using digitral signal processing, we get the vector velocity which displays the ship's speed about fore, aft, port and starboard. And this system give us the information about depth. This multi-velocity system has a large merit that is bottom and water track velocity. In addition, this has the high accuracy and can measure the water-depth according to the deep mode. And the fish finder, echo sounder or docking system will be made by applying the speed log system.

  • PDF

Collimation of cesium atomic beam using laser light pressure (레이저 광압을 이용한 세슘 원자빔의 집속)

  • 박상언
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.227-231
    • /
    • 2000
  • Thermal cesium atomic beam was collimated by transversely cooling of atoms, for which circularly polarized ($\sigma^+$ and $\sigma^-$ polarized) laser light was illuminated to the atomic beam from two perpendicular directions. As a result, the temperature corresponding to the transverse velocity component could be decreased from 430 mK to 60 11K. In addition, the spatial atomic distribution was observed according to the power difference of the two laser beams and the magnetic field applied, and the result was qualitatively coincided with the calculation result by the Doppler cooling theory. heory.

  • PDF

Measuring Technique of Burn-out Indices for 2.75″ Rocket Motor (2.75인치 로켓트 모터의 연소완료지표 계측기법)

  • Kang, Kyu-Chang;Choi, Ju-Ho;Yu, Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.106-115
    • /
    • 2000
  • This paper presents the measuring technique of time and velocity when rocket motor is burnt out for 2.751" rocket. This technique use doppler effect, frequency spectrum analysis and curve fitting. In this study, we use muzzle velocity radar for doppler signal acquisition, short-time fourier transform for spectrum analysis and curve fitting for smoothing.

  • PDF

Measurements of Three-Dimensional Flow Using 3-D Laser Doppler Velocimetry (LDV를 이용한 3차원 유동 측정)

  • 이상준;백승조
    • Journal of the KSME
    • /
    • v.34 no.4
    • /
    • pp.262-276
    • /
    • 1994
  • 본 연구를 통하여 3차원 LDV 시스템의 측정기법을 개발하였으며, 측정결과의 신뢰성을 확인하 였다. 또한 이것을 타원제트 연구에 적용함으로써 그 응용 가능성을 확인하였다. 앞으로 3-D LDV 시스템을 사용하여 신뢰성 있는 측정결과를 얻기 위해서는 아래에 기술한 몇 가지 사항을 고려하여야 한다. 1) 3차원 레이저 유속계는 정교하고 복잡한 광학시스템으로 정확한 배열을 요구한다. 광학계와 실험장치의 좌표축이 일치하지 않으면 축방향보다 측방향(lateral) 속도변동 성분에 큰 영향을 준 다. 2) LDV 측정에서 속도편심을 줄이기 위해서는 적당한 출력의 레이저, 적절한 신호처리(signal conditioning), 실험조건에 알맞는 입자를 선정하여야 한다 3) 입자를 연속적으로 균일하게 공급하여야하며 신호분석기 조작에 익숙하여 도플러신호의 질을 최적화하여야 한다.

  • PDF

The Experimental and Basic Study on Torsional Vibration of Horizontal Rotating Shaft using a Laser Measuring Equipment (레이저 계측기를 이용한 축의 비틀림 진동에 관한 실험적 기초 연구)

  • Park, I.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the nose of cam in the automobile engine was modelled into circular disk to analyze the torsional vibration of the cam shaft. The distance between disks was fixed, but the diameter of disks was changed. The torsional vibration of the cam shaft was studied experimentally by the motion of the modelled disk with changing the disk diameter. And the sizes of the modelled disk were selected not to show the natural frequencies over all the experimental ranges. The torsional vibration meter used in this study has a laser system with non-contact measurement method, which can measure both torsional angular vibration velocity and torsional angular vibration displacement simultaneously. The Experimental analysis shows that the characteristics of the torsional vibration in the horizontal rotating shaft can be considerably affected by the arrangement of the modelled disks.

  • PDF

An Experimental Study of In-Cylindeer Flow Characteristics of a High Speed Direct Injection Diesel Engine (고속 직접분사식 디젤엔진의 실린더내 유동특성에 관한 실험적 연구)

  • 정경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.22-30
    • /
    • 1996
  • In-cylinder flow of a purpose-built small HSDI Hydra Diesel engine was investigated by laser Doppler velocimetry(LDV) during induction and compression processes. The flow was quantified in terms of ensemble-averaged axial and swirl velocities, normalized by the mean piston speed, at a plane located 12mm from the cylinder head and corresponding to the mid-plane of the diametrically-opposed quartz windows at an enigne speed of 1000rpm. The formation of toroidal vortices during the intake process and the evolution and decay of swirl motion during the compression process were observed. Turbulence at around TDC of compression became homogeneous and isotropic.

  • PDF

In-Cylinder Air Flow Measurements and Turbulent Kinetic Energy Analyses (실린더 내 공기유동 측정 및 난류운동에너지 해석)

  • Yoo, S.C.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2007
  • 본 연구는 SI기관 실린더 내의 유동장 변이 과정을 3차원 LDV 측정 기술을 사용하여 흡입과 압축과정 동안 정량적으로 분석하였다. 실험은 헤드에 각각 2개의 흡입밸브와 배기밸브를 갖는 기관이 모터링되는 공회전 상태에서 실시하였다. 지난 30년 동안 텀블과 스월은 실린더 내의 평균 유동 정량화에, 난류운동에너지는 난류 측정에 많이 사용되어 왔다. 그러나 텀블은 solid body 회전 유동을 비교하는데 적절하며, 서로 다른 유동 패턴 비교에는 부적절 하다는 것이 보고되고 있는 실정이다. 3차원 LDV시스템의 우수한 공간 분석 능력은 순간적인 유동장구조와 더불어 상대적으로 미세한 유동장의 구조 까지도 측정이 가능 하도록 하였다. 따라서 측정한 결과로부터 유동장의 난류운동에너지 등가면을 계산할 수 있었다. 본 실험 결과는 실린더 내의 난류 유동장 특성을 난류운동 에너지 등가면 정보를 이용하여 세심하게 관찰할 수 있음을 제시하고 있다.

  • PDF

A Study on Measurement of Two-dimensional Velocity Distribution in River using ADCP (ADCP를 활용한 하천의 2차원 유속분포 측정 연구)

  • Yoo, Min-Wook;Kim, Young-Do;Lyu, Si-Wan;Seo, Il-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.916-920
    • /
    • 2007
  • ADCP(Acoustic Doppler Current Profiler)는 유수의 흐름을 방해하지 않으면서 물 속으로 일정 주파수의 초음파를 전송하고, 부유하는 입자들에 의해 산란되어 돌아오는 반향을 수집, 도플러효과를 이용하여 유속을 측정하는 장비이다. ADCP는 하천을 횡단하면서 순간적인 유속을 측정하므로 시간평균한 평균유속과의 차이가 발생하지만 1초에 1회 이상의 빠른 속도로 연직유속분포를 수집하면서 이를 공간적으로 평균함으로써 순간유속이 갖는 변동성을 완화시키는 특징을 갖는다. 본 연구에서는 ADCP를 활용하여 사행하천에서 수평방향 2차원 유속분포를 측정하고자 하였다. 만곡부가 교호적으로 나타나는 사행하천의 흐름구조는 매우 복잡하다. 특히 주 흐름의 수직인 단면에 나선형의 2차류가 관찰되는데, 이는 원심력과 횡방향의 수면경사 및 난류의 상호작용으로 발생된다. 주 흐름의 유속과 다른 분포를 나타낸다. 본 연구에서는 이찬주 등(2005)이 제시한 공간평균기법과 이동경로 수정을 통하여 측선별 2차원 유속분포를 측정하여 기 개발된 RAMS(서울대학교, 2007)를 적용하고 이를 검증하기 위한 자료를 확보하고자 하였다.

  • PDF

Radar Echo Signal Simulation Equipment with a Precise Range-velocity Control Capability (정밀 거리-속도 모사 기능을 갖는 레이더 반사 신호 모의장치)

  • Han, Il-Tak;Kim, Jong-Mann;Kim, Wan-Kyu;Lee, Min-Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1139-1146
    • /
    • 2010
  • Simulated target generators are used to evaluate the various radar performance. Using the radar parameters such as target range(time delay), doppler frequency, target RCS, simulated target generator can be developed. Especially moving targets are simulated by control time delay and update target signal intensive for target range. Base on this concepts, in this paper, simulated target generators are designed and developed for X-band Radar performance test. Developed equipment is evaluated its performance and then tested with X-band Radar. This paper presents these design, development, and test results of developed target generator.