• Title/Summary/Keyword: 도플러 속도

Search Result 294, Processing Time 0.028 seconds

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Study on the Retrieval of Vertical Air Motion from the Surface-Based and Airborne Cloud Radar (구름레이더를 이용한 대기 공기의 연직속도 추정연구)

  • Jung, Eunsil
    • Atmosphere
    • /
    • v.29 no.1
    • /
    • pp.105-112
    • /
    • 2019
  • Measurements of vertical air motion and microphysics are essential for improving our understanding of convective clouds. In this paper, the author reviews the current research on the retrieval of vertical air motions using the cloud radar. At radar wavelengths of 3 mm (W-band radar; 94-GHz radar; cloud radar), the raindrop backscattering cross-section (${\sigma}b$) varies between successive maxima and minima as a function of the raindrop diameter (D) that are well described by Mie theory. The first Mie minimum in the backscattering cross-section occurs at D~1.68 mm, which translates to a raindrop terminal fall velocity of ${\sim}5.85m\;s^{-1}$ based on the Gunn and Kinzer relationship. Since raindrop diameters often exceed this size, the signal is captured in the radar Doppler spectrum, and thus, the location of the first Mie minimum can be used as a reference for retrieving the vertical air motion. The Mie technique is applied to radar Doppler spectra from the surface-based and airborne, upward pointing W-band radars. The contributions of aircraft motion to the vertical air motion are also described and further the first-order aircraft motion corrected equation is presented. The review also shows that the separate spectral peaks due to the cloud droplets can provide independent validation of the Mie technique retrieved vertical air motion using the cloud droplets as a tracer of vertical air motion.

Evaluation of LDF Signal Processing Algorithms Using Self-mixing Effect of Laser Diode (LD의 자기혼합 효과를 이용한 LDF의 신호처리 알고리즘의 평가)

  • Go, Han-U;Kim, Jong-Won
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.369-377
    • /
    • 1998
  • This paper describes the results of investigations comparing the relative in vitro responses of different signal processing algorithms for laser Doppler flowmetry(LDF) using self-mixing effect of laser diode(LD). A versatile laser Doppler system is described which enabled complex signal processing to be implemented relatively simply using digital analysis. The flexibility of the system allowed a variety of processing algorithms to be studied by simply characterising the algorithm of interest under software control using a personal computer. Two in-vitro physical models are also presented which was used to maintain reproducible fluid flows Flows of particles were studied in two physical models using a 780nm laser diode source. The results show that frequency weighted algorithms(first and second moments, rate to zero moment) are responsive to particle velocity more than concentration, whereas non-weighted algorithm (zero moment responds to concentration and velocity.

  • PDF

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

A Study on the Measurement of Tissue Blood Flow by the Self-Mixing Effect of Laser Diode (레이저 다이오드의 자기혼합 효과를 이용한 조직혈류 측정에 관한 연구)

  • Ko, Ran-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.57-64
    • /
    • 1994
  • This paper describes the measurement of tissue blood flow by the the self-mixing effect of laser diode. A Laser doppler signals due to the moving object and the tissue blood flow were detected by the self-mixing effect of laser diode. The Doppler shifted frequency was changed linearly with the driving frequency of moving object and was increase after the exercise. The results of in-vivo experiment were consistent with the result of exercise physiology.

  • PDF

TIFF Performance Improvement of GPS Receiver for High-Speed Vehicles using INS and Multiple Correlator (INS와 다중 상관기를 이용한 고속 항체 GPS 수신기의 TTFF 성능 향상)

  • Kim, Jeong-Won;Jung, Ho-Chul;Hwang, Dong-Hwan;Lee, Sang-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.404-406
    • /
    • 2007
  • 본 논문에서는 유도 무기와 같이 고속으로 운동하는 항체에서 GPS 신호 탐색 시간을 줄이기 위하여 INS와 다중 상관기를 이용한 신호 획득 기법을 제안한다. 신호의 코드위상을 여러 개의 상관기에서 동시에 탐색하도륵 다중 상관기를 구성하여 코드위상 검색에 소요되는 시간을 단축시키며 INS로부터의 속도와 위치를 이용하여 도플러 주파수를 추정하고 이것을 도플러 검색 초기 값으로 사용하여 검색시간을 줄인다. 제안한 기법을 검증하기 위하여 GPS와 IMU 시뮬레이터를 이용하여 실험을 수행하였다. 실험 결과 INS와 다중 상관기를 이용하였을 때 TTFF가 매우 크게 단축되는 것을 알 수 있다.

  • PDF

A Study on the Performance of WAVE Communication System using Jakes Channel Model (Jakes 채널 모델을 이용한 WAVE 통신시스템 성능에 관한 연구)

  • Oh, Se-Kab;Choi, Jae-Myeong;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.6
    • /
    • pp.943-949
    • /
    • 2009
  • In this paper, the 5.9GHz WAVE(Wireless Access in Vehicular Environments) channel modeling is used by the Jakes channel model for the suitability of the fast wireless channel fluctuation. The performance analysed the fading signal constellation and the spectrum in the IEEE 802.11p spectrum mask, the Doppler effect, the modulation scheme. In addition, the vehicular speed, exactly the performance analysis the WAVE communication systems follow the Doppler effect.

  • PDF

Experimental Research of Cross Section Characteristics of Open-channel flows over Submerged Vegetation (침수식생 개수로 단면특성의 실험연구)

  • Choi, Sung-Uk;Yang, Won-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.930-934
    • /
    • 2007
  • 본 논문은 수리실험을 통해 침수식생 개수로의 단면특성을 살펴보고자 하는 실험논문이다. 레이저 도플러 유속계를 이용하여 측벽으로부터의 거리에 따른 침수식생 개수로의 2차원 순간속도를 측정하였다. 측정된 유속자료를 이용하여, 평균유속, 레이놀즈응력, 난류강도를 살펴보았으며, 침수식생 개수로 흐름의 단면특성을 살펴보았다. 실험결과 침수식생 개수로는 기존의 일반적인 개수로흐름과는 다른 단면 흐름특성을 보이는 것을 확인하였다. 특히 최대유속 발생지점이 수로 중앙이 아닌 측벽 근처로 이동하였으며, 이차흐름의 영향으로 인하여 흐름방향 등유속선의 물결형태와 레이놀즈응력 및 난류강도의 최대값 발생위치 이동과 같은 현상이 발생하는 것을 확인하였다.

  • PDF

Automatic Proximal Isovelocity Surface Area Determination using Non-hemispherical Flow Model and Region Based Contour Scheme for Blood Flow Rate Estimation (비반구 유동모델과 영역기반 윤곽선 기법에 기초한 자동근위 등속표면적의 결정 및 혈류량 추정)

  • 진경찬;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.449-455
    • /
    • 2000
  • 순간적으로 승모판에서 혈류가 역류하는 영역을 측정하기 위해서, PISA 방법이 자주 이용되고 있다. 이 방법은 물질보존법칙에 근거하여, 구멍을 통과하는 유체량을 isotach 표면적과 이에 대응하는 속도의 곱으로 구하는 것이다. 이러한 PISA 방법에서 사용되는 유동모델은 반구모델과 비반구모델의 형태인데, 이는 isotach 표면적이 반구이거나 비반구임을 가정하여 계산된 것이다. 이러한 isotach 모델링에서는 isotach의 높이와 폭의 결정이 유체량을 추정하는데 아주 중요한 변수가 된다. 본 연구에서는 in-vitro 칼라 도플러 영상으로부터 PISA 영역을 추정을 위하여 영역기반을 근간으로 하는 비반구모델에 대한 표면적 추정방법을 제안하였다. 이 방법의 타당성을 알아보기 위해 180개의 칼라 도플러 영상에 대해 isotach의 높이와 폭을 추정한 결과, 기존의 에지기반방법이 19개 영상에서 에러를 가지는 반면, 제안한 방법에서는 에러영상이 없음을 알 수 있었다.

  • PDF

The Performance Evaluation of Forward Link of CDMA System Adopting Closed-loop Transmit Beamforming with Feedback Channel Structure (폐쇄 루프 송신 빔 성형을 적용한 CDMA 시스템의 귀환 채널 구조에 따른 순방향 링크 성능 연구)

  • 오지영;안철용;한진규;김동구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.7A
    • /
    • pp.1152-1161
    • /
    • 2001
  • 본 논문에서는 이동국 수신 신호의 SINR을 최대화하는 빔 성형 알고리듬을 이용하여, 폐쇄 루프 송신 빔 성형기술을 적용한 순방향 링크 CDMA 시스템에서의 안테나 수, 귀환 채널의 구조, 귀환 지연 등과 시스템 성능과의 상관관계를 연구하였다. 폐쇄 루프 전송 빔 성형에서는 이동국이 각 안테나가 겪는 채널을 추정하여 수신 SINR을 최대화시키는 가중치 벡터를 계산하고, 귀환채널을 통해 가중치 벡터의 양자화된 진폭과 위상정보를 전송한다. 컴퓨터 모의 실험 결과는 송신 안테나가 2개, 3개, 4개로 늘어남에 따라 빔 성형 이득은 단일 송신 안테나와 비교해 $10^{-5}$ BER 근방에서 4.2dB, 5.8dB, 7dB로 증가하지만 양자화 오류에 의한 성능 저하 또한 0.1dB, 0.6dB, 1.3dB로 커지는 것을 보여준다. 또한 순방향 채널의 최대 도플러 주파수가 100Hz일 때에는 귀환 채널을 통한 소신 가중치 벡터를 보다 빠르게 갱신하는 것이 가중치 벡터의 양자화 레벨의 수를 늘여주는 것보다 $10^{-5}$ BER 근방에서 0.6dB 더 좋은 성능을 보이며, 최대 도플러 주파수가 10Hz일 때에는 가중치 벡터의 갱신 속도를 늘이기 보다 양자화 레벨의 수를 늘여주어 정확한 가중치 벡터를 전송하는 편이 0.9dB의 성능 향상을 보인다. 두 전력제어 그룹 길이의 귀환지연으로 인한 성능저하는 채널의 최대 도플러 주파수가 50Hz인 경우가 채널의 최대 도플러 주파수가 100Hz인 경우보다 $10^{-5}$ BER 근방에서 0.3dB 정도 더 작다. 또한 AOS가 3$^{\circ}$인 경우가 AOS가 $10^{\circ}$인 경우보다 $10^{-5}$ BER 근방에서 1.9dB 정도, 주파수 선택적 페이딩 채널이 주파수 비선택적 페이딩 채널보다 $10^{-5}$ BER 근방에서 1dB 정도 귀환 지연으로 인한 성능의 저하가 작다.

  • PDF