• 제목/요약/키워드: 데오도라이트 측정 시스템

검색결과 9건 처리시간 0.026초

데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도 (A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

비접촉식 3차원 정밀 측정 기술 동향

  • 윤용식
    • 항공우주산업기술동향
    • /
    • 제4권1호
    • /
    • pp.61-67
    • /
    • 2006
  • 현대 산업이 고도화, 선진화됨에 따라 1.5 m 이상의 크기를 갖는 중.대형 시설 및 장비에 대한 설치 요구조 건 및 운용상의 정밀도 유지가 더욱 중요해지고 있다. 이를 위하여 비접촉식 3차원 정밀 측정 장비인 데오드 라이트 측정시스템, 사진 측정 시스템 및 레이저 측정 시스템 등의 사용이 점차 증가하고 있는 추세이다. 본 글에서는 이들 측정 장비의 측정 원리 및 적용 사례 등을 중심으로 최근의 정밀 측정 기술 동향에 대하여 기 술하였다.

  • PDF

컴퓨터 제작 홀로그램과 데오도라이트를 이용한 인공위성 카메라 주 반사경의 정점 좌표 측정 (Measurement of Primary-mirror Vertex Coordinates for a Space Camera by Using a Computer-generated Hologram and a Theodolite)

  • 강혜은;송재봉;양호순;김학용
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.146-152
    • /
    • 2017
  • 우주용 인공위성 카메라를 구성하는 반사경의 정렬은 광학계의 고분해능, 고성능을 얻기 위한 중요한 과정 중 하나이다. 반사경들의 상호정렬에는 큐브미러(cube mirror)가 대신 사용되기 때문에, 각 반사경과 해당 큐브미러 간의 상호위치관계 정보가 우선 필요하다. 따라서 우주용 카메라 반사경들의 정렬을 위해 각 반사경의 정점과 해당 큐브미러의 상대 좌표값을 정확하게 측정해야하며, 본 논문에서는 컴퓨터 제작 홀로그램(computer-generated hologram, CGH)의 정렬용 세그먼트와 광섬유를 이용하는 새로운 측정 시스템을 제안함으로써 우주용 카메라를 구성하는 반사경의 정점을 요구조건 이내로 측정할 수 있었다. 측정 시스템은 광학계 평가용 간섭계, CGH, 광섬유, 반사경으로 구성되어 있으며, 최종적으로 데오도라이트를 이용해 큐브미러를 기준으로 주 반사경의 정점에 위치한 광섬유 끝단의 3차원 상대 좌표값을 $25{\mu}m$ 이하의 정밀도로 측정할 수 있었다.

데오도라이트 시스템의 측정 오차 요인에 대한 연구 (A Study on Measurement Error Factors of Theodolite System)

  • 윤용식;이동주
    • 한국공작기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.

데오도라이트 시스템의 측정 오차 요인에 관한 연구 (A Study on Measurement Error Factors of Theodolite System)

  • 박홍철;윤용식;최석원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.272-275
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100 m. And the system is used for the measurement of a product for middle and large scale. This study was performed for finding the measurement error factors of the system. We could know that the main error factors are temperature, illumination and expertness. And we could find the measurement errors are $\pm$ 0.045 mm at temperature conditions is 2$0^{\circ}C$ and $\pm$ 0.012 mm at illumination condition is 300 lux. Also the results had significant differences by combinations of operator's expertness.

  • PDF

데오도라이트 시스템의 측정 불확도 연구 (A Study on Measurement Uncertainty of Theodolite System)

  • 이건탁;이동주;박흥철;오재명
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.229-233
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is 0.5 mm or better for distance 0 ~ 100m. And the system is used for a product of middle and large scale. This study is performed for the measurement uncertainty of the system. We could know that the main uncertainty factors are temperature, illumination and skill. And, we perform the study for the effect according to the height difference of scale bar. And, we calculated the measurement uncertainty with those factors.

  • PDF

데오드라이트를 이용한 이중 추력기 모듈의 정밀정렬측정에 관한 연구 (A Study on Accurate Alignment Measurement of Dual Thruster Module Using Theodolite)

  • 황권태;문귀원;조창래;이동우;이상원
    • 대한기계학회논문집A
    • /
    • 제36권11호
    • /
    • pp.1399-1404
    • /
    • 2012
  • 인공위성은 우주궤도에서의 임무수행 및 작동 특성을 가지고 있기 때문에 수리 불가능한 특성을 지니고 있다. 따라서 인공위성에 사용되는 탑재체들이 정상적인 기능을 발휘하기 위해서는 정확한 조립 및 설치가 되어야 한다. 또한 극심한 발사환경과 우주환경에서 변화와 이상이 발생하지 않아야 하므로 발사환경시험, 우주환경시험 전 후로 정렬 측정이 수행되어 부품 및 시스템 레벨에서의 변화에 대한 측정이 요구되어지는 실정이다. 최근 중 대형 산업품에 대한 비접촉식 3차원 정밀 측정 장비가 개발되고 있다. 이러한 장비 중 하나인 데오도라이트 측정 시스템이 항공우주산업에 널리 활용되고 있다. 따라서 본 논문에서는 다목적실용위성의 자세제어에 사용되는 이중 추력기 모듈의 각도를 데오도라이트를 이용하여 정렬 측정 및 이에 대한 신뢰도 분석을 수행하였다.

KSLV-I 킥모터 시스템 추력 축 정렬 (KSLV-I Kick Motor System Thrust Axis Alignment)

  • 이한주;정동호;오승협
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.138-142
    • /
    • 2010
  • 발사체의 기체 축과 추력 축이 요구 조건에 맞게 정렬되지 않을 경우엔 자세 제어 오차가 허용 범위를 초과할 수 있으며, 심각할 경우 미션 실패로 이어질 수 있다. 일반적인 발사체의 추력 축 정렬에는 데오도라이트와 레이져 트레커를 사용하는 광학적 방법과 턴테이블을 이용하는 기계적 방법이 사용된다. 본 논문에서는 3차원 측정 결과로부터 획득된 형상 정보에 기반하여 경사도계를 사용하는 킥모터 시스템의 추력 축 정렬 방법에 대해서 다룬다.