• Title/Summary/Keyword: 더운 환경

Search Result 28, Processing Time 0.033 seconds

A Way for Creating Human Bioclimatic Maps using Human Thermal Sensation (Comfort) and Applying the Maps to Urban and Landscape Planning and Design (인간 열환경 지수를 이용한 생기후지도 작성 및 도시·조경계획 및 디자인에의 적용방안)

  • Park, Soo-Kuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.1
    • /
    • pp.21-33
    • /
    • 2013
  • The purpose of this study is to find applicabilities of human bioclimatic maps, using human thermal sensation(comfort) in summer, with microclimatic in situ data and computer simulation results at the study site of downtown Daegu. This includes the central business district(CBD) area and two urban parks, the Debt Redemption Movement Memorial Park and the 2.28 Park, for urban and landscape planning and design. Climatic data and urban setting information for the analysis of human thermal sensation were obtained from in situ measurement and the geographic information system data. As a result, the CBD had higher air temperature than the parks when the wind speed was low. Relative humidities were opposite to the air temperature. Especially, same directional streets with local wind direction had lower air temperature than streets perpendicular to the wind direction. The most important climatic variable of human thermal sensation in summer was direct beam solar radiation. Also, creating shadow areas would be the most relevant method for modifying hot thermal environments in urban areas. The most effective method of creating shadow patterns was making a tree shadow over a pergola, and the second best one was making a tree shadow on the front of north directional building walls. Moreover, how to plant trees for creating shadow patterns was important as well as what kind of trees should be planted. The results of human thermal sensation were warm to very hot at sunny areas and neutral to warm at shaded ones. At the sunny areas, wide, squared shape areas had a little bit higher thermal sensation than those of narrow streets. The albedo change of building walls 0.15 and ground surface 0.1 could change 1/6 of a sensation level at the shaded areas and 1/3 at the sunny ones. These microclimatic approaches will be useful to find appropriate methods for modifying thermal environments in urban areas.

Current Research Status of Postharvest and Packaging Technology of Oriental Melon (Cucumis melo var. makuwa) in Korea (국내 참외의 수확 후 관리 및 포장기술 연구)

  • Kim, Jung-Soo;Choi, Hong-Ryul;Chung, Dae-Sung;Lee, Youn-Suk
    • Horticultural Science & Technology
    • /
    • v.28 no.5
    • /
    • pp.902-911
    • /
    • 2010
  • Oriental melon ($Cucumis$ $melo$ var. $makuwa$) is a popular and high-value market fruit cultivated in Korea. Consumers are becoming increasingly interested in oriental melon as a healthy diet over the past few years. However, the melons have relatively high quality loss because the fruit are mainly produced for a limited period of time in the summer season. Lack of the proper postharvest treatments and high temperature exposure at harvest or during distribution are the most critical environmental factors limiting postharvest life of fruit. This review focuses on the overview of current research studies for postharvest treatment and functional packaging technology of oriental melon in Korea. Major physiological problems of the harvest fruit include the ripening process in quality changes of the produce such as loss of weight, firmness, flavor, and decay during the storage periods. Low temperature at 7 to $10^{\circ}C$ with high relative humidity of 90 to 95% is the suitable environmental condition used to maintain the quality of fresh oriental melon. Controlled atmosphere (CA) storage or modified atmosphere (MA) packaging can be used as supplemental treatments to extend postharvest-life. For oriental melon, an optimum CA is currently recommended to be 2-3% oxygen and 5-10% carbon dioxide atmosphere. Precooling, pretreatments of ethylene action and functional packaging system can be applied to oriental melon after harvest in order to extend storage life. Major active packaging technologies are concerned with a selectively gas permeable film related to respiration of produce and the packaging applications of ethylene removal, antimicrobial, and antifogging substances to keep the effective freshness of fruit.

Consumer Intention to Purchase Domestic/Foreign Brand Jeans;Beliefs, Attitude, and Individual Characteristics. (국내 및 외국 상표 청바지의 구매의도에 따른 평가기준에 대한 신념과 추구이미지 및 의복태도의 차이연구)

  • 고애란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.263-272
    • /
    • 1994
  • The purpose of this study was to identify factors that might distinguish those who have a high level of Intention to purchase each of domestic, foreign designer and national brand jeans from those who have a low intention in terms of evaluative criteria belief, ideal jeans image and clothing altitude. The sample consisted of 198 male and 197 female students from five universities in Seoul. The questionnnaire consisted of 50 seven-point semantic differential scales dealing with evaluative criteria and ideal jeans image, beliefs about and intention to purchase domestic, foreign designer and foreign national brand jeans and 25 Likert type clothing attitude scales. Based on a series of t-tests the results showed that color and design were the most influencing factor among the evaluative criteria belief, regardless of brand type, while durability, accessory, sewing were the least. Sexy image, brand consciousnees and fashion interest were the important factor that distinguish high intention to purchase group fro)m low intention to purchase group.

  • PDF

Analysis of Meteorological Elements in the Cultivated Area of Hadong Green Tea (하동녹차 재배지역의 기상요소별 분석)

  • Hwang, Jung-Gyu;Kim, Jong-Cheol;Cho, Kyoung-Hwan;Han, Jae-Yoon;Kim, Ru-Mi;Kim, Yeon-Su;Cheong, Gang-Won;Kim, Yong-Duck
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.2
    • /
    • pp.132-142
    • /
    • 2010
  • Characteristics of meteorological elements were analyzed at Hwagae and Agyang where are the representative areas of Hadong green tea cultivation in Korea. An automatic weather monitoring system (AWS) and a simple data log were employed to measure meteorological data such as temperature, relative humidity, precipitation, and wind direction and speed for 2009. The annual average air temperature of Hwagae and Agyang was 14.5 and 14.2, respectively, showing the warmest month in August ($25.4^{\circ}C$ for Hwagae and $24.9^{\circ}C$ for Agyang) and the coldest month in January ($0.3^{\circ}C$ for Hwagae and $0.2^{\circ}C$ for Agyang). Annual average of daily temperature difference (= daily maximum temperature - daily minimum temperature) was $11.3^{\circ}C$ for Hwagae and $11.1^{\circ}C$ for Agyang. Hwagae and Agyang had 62.7% and 65.3% of the annual average relative humidity, respectively. Annual precipitation was 1387 mm for Hwagae and 1793 mm for Agyang of which were higher of 605mm for Hwagae and 835 mm for Agyang compared to that in 2008. Majority of precipitation occurred between May and August, attributing 77.6% for Hwagae and 76.6% for Agyang to the annual precipitation. The annual total sunshine duration was 2054.3 hrs in Hwagae with the longest monthly sunshine duration in May (235.1 hrs) and the shortest monthly sunshine duration in July (102.5 hrs). Dominant wind direction changed seasonally from northwesterly wind in fall and winter to southeasterly wind in spring and summer. The annual average wind speed was 1.5 m $s^{-1}$ with the highest monthly wind speed of 2.0 m $s^{-1}$ in December and the lowest monthly wind speed of 1.1 m $s^{-1}$ in February. It is expected that continuous observation and assessment of meteorological data will improve our understanding of optimal environmental conditions for green tea cultivation and be used for developing models of green tea cultivation in the Hadong area.

Physiological Responses of Wearing Safety Helmet with Cooling Pack in Hot Environment (머리 냉각시의 인체생리반응 - 안전모 착용을 중심으로 -)

  • Choi, Jeong-Wha;Park, Joon-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.955-965
    • /
    • 2007
  • Safety helmets are used widely in various industries by workers since they are legally required to wear them. However, thermal discomfort is one of the major complaints from helmet users. To relieve this problem, frozen gelled packs can be considered for use inside the helmets. In this paper, tests were performed on humans to evaluate the physiological strains of wearing safety helmets and to investigate the effects of using frozen gelled packs inside the helmets. Experiments were conducted in a climatic chamber of WBGT $33{\pm}1^{\circ}C$ under four differed experimental conditions: 1) not wearing a safety helmet(NH); 2) wearing a safety helmet with frozen gelled pack A(HA); 3) wearing a safety helmet with frozen gelled pack B(HB); and 4) wearing only a safety helmet(OH). The results were as follows. First, when comparing NH with OH, physiological responses such as $\bar{T}_{sk},\;T_r$, HR and sweat rate were significantly higher in OH and subjective sensations were reported as less hot and more comfortable than NH(p<.05). Second, in regard to the frozen gelled packs inserted inside the safety helmets, some physiological responses in HA were different from those in HB, according to the two different types of packs. HA was hotter, more uncomfortable and less exhausted than HB. However, result from both HA and HB were lower than those from OH in terms of temperature and humidity inside safety helmet, sweat rate, $T_r$ increase, heat storage(p<.05). When wearing safety helmets with frozen gelled packs, it was shown that heat strain can be alleviated. These results are expected to help millions of workers who complain that wearing safety helmets is uncomfortable and messy.

Analysis of Temperature and Humidity Distributions according to Arrangements of Air Circulation Fans in Single-span Tomato Greenhouse (토마토 단동온실에서 공기순환팬 설치 방법에 의한 온실 내 온습도 분포 분석)

  • Lee, Tae Seok;Kang, Geum Choon;Paek, Yee;Moon, Jong Pil;Oh, Sung Sik;Kwon, Jin Kyung
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2016
  • This study was aimed to investigate the effect of air-circulation fans on air temperature and relative humidity in a single-span tomato greenhouse (W: 7m, L: 25m, H: 3.2m). According to standard of fan layout by ASAE (1997), a total of 10 fans were bilaterally arranged in 2 rows in the experimental greenhouse. The distributions of air temperature and relative humidity were measured from 6 pm to 8 am under different conditions, with and without fans. The measurement heights were 0.7m, 1.7m and 2.7m. Under the condition of "fans off", the spatial differences of air temperature and relative humidity between upper and lower sides were $1.7^{\circ}C$ and 10.8%, respectively. The operation of 10 fans showed their differences to $0.1^{\circ}C$ and 3.2%. The number of fans and installation direction were evaluated their performance on reducing the spatial variation of air temperature and relative humidity. The experimental layouts were 5 and fans in 2 rows (bilaterally) and 10 fans in the one (same) direction. Under the condition of "6 fans on" and "5 fans on", the spatial differences of air temperature and relative humidity between upper and lower side were $0.3^{\circ}C$, 3.4% and $0.3^{\circ}C$ and 4.0%. The operation of 10 fans in the one direction reduced their differences to $0.5^{\circ}C$ and 4.9%. The overall findings of this study showed that there was no significant differences under each condition. Therefore, this study suggested that it is more economic and effective to install five fans in 2 rows (bilaterally) in the greenhouse (W: 7m, L: 25m, H: 3.2m).

Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House (지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석)

  • Choi, H.C.;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.;Park, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.99-108
    • /
    • 2010
  • The principal objective of this study was to investigate the cooling effects of geothermal heat pump system (GHPS) in farrowing house. A total of 96 sows were allocated to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in summer season. During the experimental period of four weeks, the highest outside temperature observed was approximately $34.1^{\circ}C$, GHPS decrease indoor temperature of pig housing up to $30.9^{\circ}C$, but conventional pig housing was similar to outside temperature. Dust concentrations (maximum 61.4%) of particulate matter less than $10{\mu}m$ (PM 10) in GHPS-housing were lower than the conventional housing. GHPS showed no signigicant difference in carbon dioxide emission, whereas the ammonia gas concentration was significantly decreased in GHPS-housing compared to that of conventional housing. Sows in GHPS-housing showed significantly lower respiratory rate than those of the control group. GHPS did not affect hormone level, litter size and birth weight, but weaning weight of piglets was influenced by GHPS. Feed consumption of sows was significantly increased in GHPS-housing compared to the conventional hosing. These results suggest that GHPS decrease dust concentration, ammonia gas emission and indoor temperature of pig housing and may affect performance in sows and weaned piglets.

Thermophysiological Responses of Wearing Safety Hat for Working at a Hot Environment (서열환경하에서 안전모 착용시의 인체생리학적 반응)

  • 박소진;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • The present study is aimed to investigate the effect of the safety hat on the balance of body temperature by observation of the physiological response under hot working environment. The experiment was carried out in a climate chamber of 3$0^{\circ}C$, 50%RH for 70 minutes. To compare the two kinds of safety hat, 5 healthy male subjects worn safety hat without hole (called 'without hole') or safety hat with hole (called 'with hole') according to a randomized cross-over design. The main results of this study are as fellows: Rectal temperature and heart rate were significantly lower level in 'with hole'than in 'without hole'. The mean skin temperature was significantly higher in 'without hole'than in 'with hole'. Blood pressure were significantly low in 'with hole'. Sweat rate which was measured by weight loss before and after experiment was higher in 'without hole'. In subjective ratings, subjects replied more hot, more uncomfortable and more wet, they felt more fatigue in condition of 'without hole'. Work ability which was measured by a grip strength dynamometer was higher in 'with hole'. Safety hat which can be used for safety of the brain in work place is meaningful device of behavioral thermoregulatory response under the hot working environment. The safety hat which is designed for proper ventilation and hygiene can maintain the homeostasis of body temperature by releasing body temperature efficiently.