• Title/Summary/Keyword: 대학건물

Search Result 351, Processing Time 0.023 seconds

Microbubbles Increase Glucosinolate Contents of Watercress (Nasturtium officinale R. Br.) Grown in Hydroponic Cultivation (마이크로버블을 이용한 수경재배 물냉이의 글루코시놀레이트 함량 증대)

  • Bok, Gwonjeong;Choi, Jaeyun;Lee, Hyunjoo;Lee, Kwangya;Park, Jongseok
    • Journal of Bio-Environment Control
    • /
    • v.28 no.2
    • /
    • pp.158-165
    • /
    • 2019
  • The effects of microbubbles on glucosinolate accumulation and growth of watercress (Nasturtium officinale R. Br.) were investigated. Watercress plant at the 4th mature leaf stage (2 weeks old) were exposed to microbubbles or non-microbubbles generated in an Otsuka-house nutrient solution for 3 weeks in a controlled environment culture room. Stem length of the watercress grown under the microbubbles was 41% shorter than that of the non-microbubbles, showing significantly different. However, shoot fresh and dry weights, root length, leaf length, leaf width, SPAD, and quentum yield of the watercress were not significantly different between treatments. Glucoiberin, glucobrassicin, gluconapin, gluconasturtiin of the watercress grown under microbubbles, excepted for 4-methoxyglucobrassicin, were significantly higher than those of the watercress grown in non-microbubbles. In addition, watercress grown under microbubbles for 3 weeks contained 85% (${\mu}mol/g$ DW) and 65% (${\mu}mol/plant$) more total glucosinolate, respectively. Results indicated that microbubbles generated in a deep flow technique hydroponics system could increase the accumulation of glucosinolate without growth reduction.

Growth Analysis of Maize with Tillers (분얼형 옥수수의 생장분석)

  • Kang, Kwon-Kyu;Lee, Hee-Bong;Lee, Won-Ku;Choe, Bong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.3
    • /
    • pp.280-287
    • /
    • 1989
  • In order to know growing habit of the maize bearing tillers, IK//IRI/B68 with tillers was grown and compared with Jinjoo Ok which is not tillering, and several parameters were measured for analysis. The results obtained were summarized as follows. 1. The plant height and fresh weight of IK//IRI/B68 were lower than those of Jinjoo Ok until the tasseling stage of IK/ /IRI/B68, while then plant height and fresh weight of IK//IRI/B68 were higher than those of Jinjoo Ok after the tasseling stage of IK//IRI/B68. 2. The average number of tillers per plant of IK//IRI/B68 at maturity was 3.7 and the average tiller height of IK//IRI/B68 was almost the same as the height of the main stem. 3. The dry weight of IK//IRI/B68 at the early growing stage was lower than the check hybrid Jinjoo Ok, while it was higher than Jinjoo Ok at the later growing stage. 4. The LAI of IK//IRI/B68 after full expansion of the leaves was greater than that of Jinjoo Ok The LAIs of IK//IRI/B68 and Jinjoo Ok were 12.6 and 5.8, respectively. 5. The CGR of Jinjoo Ok was greater than that of IK//IRI/B68 until earey July while the CGR of Jinjoo Ok was lower than that of IK//IRI/B68 as the tillers of IK//IRI/B68 were fully developed. 6. The LAR and RGR of IK//IRI/B68 were greater than those of Jinjoo Ok until mid-July. The RGR of IK//IRI/B68 seemed to be affected by both NAR and LAR. The RGR of Jinjoo Ok seemed to be affected by LAR.

  • PDF

Influences of Water-logging Period at Different Growth Stages on Agronomic Characters in Sesame (참깨 생육기별 침수기간이 주요형질에 미치는 영향)

  • Choi, Hyoung-Koog;Kim, Yong-Jae;Guh, Ja-Ock;Hwang, Jong-Kyu;Kim, Hak-Jin
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.3
    • /
    • pp.224-232
    • /
    • 1990
  • This study was conducted to find out the improvement of water-logging injury which is an important factor of yield loss in sesame. Water-logging was treated at 10, 25, 40, 55 and 70 days after emergence for 24, 48 and 72 hours in sesame variety 'Ansanggae'. Some important agronomic characters were investigated after treatment. The important agronomic characters such as plant height, leaf area, dry matter weight, capsule setting stem length, number of capsules per plant, ripenning rate and 1,000 grain weight were most susceptible at 55 days after emergence by the water-logging treatment, and the longer period of water-logging, the more susceptible. Allmost of the useful agronomic characters were able to get over injury of water-logging only within 25days after emergence, but could not get it over since 40days. Grain yield was decreased due to the water-logging treatment by 69 to 86% in 55 days after emergence that is most susceptible stage for water-logging as compared with the untreated control which is 13g per pot, and the longer period of water-logging induced the lower yield. Oil content of grain showed significant decrease only in 55 days after emergence but the composition of fatty acid did not influenced by the water-logging.

  • PDF

The Effects on Yield, Fruit Characteristics and Growth caused by Low Temperature Treatment of Cucumber (Cucumis sativus L.) Seedling (오이묘의 저온처리가 생육, 과실특성 및 수량에 미치는 영향)

  • Nam, Y.I.;Woo, Y.H.;Hong, K.H.;Lee, K.H.;Suh, G.S.;Kim, J.K.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.10 no.1
    • /
    • pp.77-90
    • /
    • 2008
  • This study was conducted to investigate the influence of chilling temperature and duration at different seeding stages on yield, fruit characteristics and growth of cucumber in a greenhouse. When 20-day-old cucumber were exposed to 0 and 3℃ for 10 hours, 25 and 30% reduction in the main stem elongation rate and 34 and 37% reduction in total leaf area per plant were observed. The reduction in stem elongation and total leaf area was apparently associated with the increases in chilling duration. Exposure of seedlings to 6℃ failed to causes any significant differences in growth as compared to the unchilled plants. Repeated exposure of seedlings to 3℃ chilling for 10 hours per day increased the chilling injury significantly. The seedlings exposed to low temperature for 3 consecutive days exhibited severe injury as compared to the seedlings exposed to chilling treatment only once or twice. Fruit elongation rate was inhibited by approximately 10%, such as 0.59~2.26cm/day, with chilling of 15 hours at 0℃ as compare to 0.61~2.60cm/day in the non-chilled plants. Chilling treatment at 0~3℃ for 10 hours reduced the percentage of marketable fruits by 25~26%. while it increased the percentage of severely bent fruits significantly. Total fruits yield was reduced by 15~25% in cucumber plants when the chilling treatment was given to 20-day-old seedlings and by 22~37% in 30-day-old seedlings. This shows that, Larger seedlings were more sensitive to chilling. Total yield was also influenced by the duration of chilling. Definitely, at 0℃, 5-hour chilling treatment caused 18% of reduction, 10-hour caused 30%, and 15-hour caused 36%, respectively.

Seeding Vigor of Birdsfoot Trefoil Entries Differing in Seed Size (종자 크기가 다른 두 계통의 벌노랑이 유식물의 활력 비교)

  • Hur, S.N.;Nelson, C.J.;Beuselinck, P.R.;Coutts, J.H.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.14 no.3
    • /
    • pp.186-194
    • /
    • 1994
  • Lack of seedling vigor is considered a serious deterrent to use of broadleafed birdsfoot trefoil (Lorus comicul~rus L.). Our objectives were to compare early seedling growth of broadleafed birdsfoot trefoil cultivar "MO-20" and the large-seeded accession 302921 at $15^{\circ}C$ and $25^{\circ}C$. in controlled-environment chambers. Cabon dioxide exchange rate (CER) was measured in a closed or open system using infrared gas analysis. Dark respiration rate was measured manometrically. Net carbon accumulated per day and growth analysis of the seedlings were calculated. Initial seed mass of 302921 was 3.5 times larger and final cotyledon area was 2 times larger than those of MO-20, and early seedling growth was better. But, from 3 weeks after emergence until the end of the test period at $25^{\circ}C$, MO-20 showed higher CER per unit leaf area and faster dry weight accumulation than did 302921. Compared with $25^{\circ}C$, growth of MO-20 at $15^{\circ}C$ was suppressed more than that of 302921. Dark respiration rate of MO-20 was slightly higher than that for 302921, but not COz uptake per day for MO-20 was highest at$25^{\circ}C$ and lowest at $25^{\circ}C$. The relative growth rate (RGR) of MO-20 was higher than 302921 at $25^{\circ}C$ due to high net assimilation rate, but there was little difference in RGR between entries at $15^{\circ}C$.}C$.

  • PDF

Comparative Evaluation of Impervious Ratio between KNU and HKU Campus Using Google Earth (Google Earth를 이용한 경북대와 홍콩대 캠퍼스의 불투수율 비교평가)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.3
    • /
    • pp.421-433
    • /
    • 2009
  • The impervious ratio was frequently employed as a fundamental attribute will be used as a proxy of the total environmental burden in the urban area since it may contribute as much or more on a cumulative basis to the overall environmental condition. This research proposes a comparative evaluation framework in a more objective and Quantitative way for an impervious ratio in the university campus, using the Google Earth. Two university campuses (Kyungpook National University: KNU, Hong Kong University: HKUJ were selected as survey objectives in order to evaluate the potential of Google Earth in monitoring impervious conditions in the campus. The 61cm resolution of Quickbird data combined with digital map realistically identified the major type of impervious surface such as road, building and parking lots in the study area by large scale spatial precision. The impervious zones with persistently high road density and parking space were specifically identified over the KNU campus while the HKC campus was intensively covered by tree, resulting in almost twice (31%). as compared to KNU (18.4%), The methods of characterizing impervious surface used in this study are easily replicable using data that are primarily publicly available, and therefore the collection of impervious coverage data via Google Earth is, therefore, proposed as a practical alternative.

  • PDF

A Study on the Evaluation of Thermal Performance of Aluminium Alloy Window Frame considering 2D Steady-state Heat Transfer applied to Educadtional Facility (2차원 정상전열해석을 통한 교육시설의 알루미늄 창호 열성능 평가에 관한 연구)

  • Kang, Jung-Hun;Kwak, Young-Kuhn;Noh, Seung-Uk;Park, Dae-Ho;Lee, Ju-Ho;Hong, Wan-Pyo;Hwang, In-Kyu;Park, Tong-So
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.122-125
    • /
    • 2011
  • 본 연구에서는 기존 교육시설에 설치된 알루미늄 합금 창의 2차원 정상상태 전열해석을 통한 열성능 평가를 수행하였다. 교육시설의 주요 창호재료로 적용된 알루미늄은 열전도율이 $175 \;Kcal/m^2h^{\circ}C$ 정도로 플라스틱 소재와 비교하여 매우 불리하여 기존 시설에 설치된 알루미늄 창호는 열손실의 주요인으로 지적되고 있다. 본 연구에서는 이러한 점에 착안하여 충남 서산지방에 위치한 대학건물의 알루미늄 합금 창호의 열성능 평가에 관한 연구를 수행하여 다음과 같은 해석 결과를 도출하였다. (1) 2차원 정상상태 전열해석을 위한 경계조건은 국토해양부고시 건축물의 에너지절약설계기준의 [별표 6] 중부지방 냉난방장치의 용량계산을 위한 설계 외기온 기준과 [별표 7]의 실내온도 기준을 적용하여 여름철 실내 $27^{\circ}C$, 실외 $31.3^{\circ}C$, 겨울철 실내 $21.0^{\circ}C$, 실외 $-9.6^{\circ}C$ 로 설정하고 해석한 결과 열관류율은 알루미늄 합금 창호는 $U=9.631 \;W/m^2K$, 복층유리 $U= 2.382 \;W/m^2K$로 여름철과 겨울철 동일한 해석결과치가 산출되었다. (2) 산출된 열관류율 해석결과를 건축물의 에너지절약설계기준 [별표 3] 열교차단재가 적용되지 않은 금속제 창의 단열성능 중 일반복층창 성능기준인 $4.0 \;W/m^2K$와 비교할 때, 알루미늄 창틀을 통하여 225%의 열량이 손실됨을 보여 주고 있다.

  • PDF

A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation (열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구)

  • Kim, Seok-Hyun;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

A Study on Environment-Friendly Characteristics of campus buildings for creating a green campus (그린캠퍼스 조성을 위한 대학건물의 친환경적 특성에 관한 연구)

  • Jeong, Sook-In;Nam, Kyung-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.221-228
    • /
    • 2009
  • Recently severity of ecological adaptation and climatic change due to global warming grows larger. According to the fourth report of IPCC in 2007, emission quantity of the earth greenhouse gas(GHGs) generated by activity of mankind increased with 80% since 1970. And it is forecasted that worldwide greenhouse gas will be increased with 25~90%(corresponding to $CO_2$) between 2000 and 2030. This increment of greenhouse gas($CO_2$) is expected to raise average temperature of the earth with the maximum $6.4^{\circ}C$, and sea surface with 59cm in 2090. Like this, destruction of environment by greenhouse gas is regarded as universal problem threatening the existence, not only the problem of one nation. Consequently, systematic correspondence to the global warming at the aspect of energy consumption is also needed in Korea. From the analysis result of 'Statistics of Energy Consumption' published by Green Korea in 2007, energy consumption increment of domestic universities was higher as many as 3.7 times than 22.5% of the whole energy consumption increment in our country. This says to be the direct example which shows that universities are huge sources of greenhouse gas emission. New constructing and enlarging buildings of each universities within campus are the most major reason for such a large increment of energy consumption in universities. The opinion that the possibility of causing energy waste and efficiency reduction is raised by increased buildings of universities has been propounded. That is, universities should make concrete goal and the plan for reducing emission of green house gas against climatic change, and should practice. Accordingly, there is the meaning that 2 aspects of environment-friendly design characteristics, that is application of energy utilizing technology, material usage of energy efficiency-side and environment-side, and introduction of natural element in the environmental aspect, were analyzed for facilities of university campus designed in environment-friendly point of view from initial stage of plan, and direction of environment-friendly design of university facilities in the future was groped in order to grasp environment-friendly design tendency of internal and external University facilities based on this analysis of this paper.

Prediction of Urban Inundation using SIND Model : Application of Nakdong River Basin (SIND Model을 적용한 도시침수 예측 : 낙동강 유역 적용)

  • Kim, Dong Hyun;Lee, Seung Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.293-293
    • /
    • 2019
  • 최근 도심지 침수예방을 위해 구조적 비구조적인 대책 등이 수행되어 왔으나, 도심지의 국지성 호우의 발생빈도가 증가함에 따라 단시간의 도심지 침수예측의 중요성이 다시 대두되고 있다. 이에 도심지 침수 예측을 위해서는 수치모의 프로그램을 사용한 연구가 진행되어 왔으나, 국지성 호우에 의한 침수를 막을 만킁의 실시간 위험예측은 아직까지 힘든 실정이다. 한편 해양재난의 침수를 예방하기 위해서 국립재난안전연구원(2017)에서는 과학적 보간법을 적용한 침수예측 모형인 SIND(Scientific Interpolation for Natural Disaster) Model을 개발한 바 있다. 따라서 본 연구에서는 SIND Model을 도심지 침수예측에 적용하여 집중호우와 같은 단기간의 침수를 예방하고자 한다. SIND Model은 기 구축된 침수예상도를 활용하여 모든 시나리오에 대한 침수 위험도 등급을 실시간으로 평가하는 모형이다. 국토부에서 제공하는 국가홍수위험지도와 내수침수지도를 활용하였고, SIND Model은 Comsol Multyphisic를 활용하여 침수예측지도를 생성하였다. 기존에 해양재난 예측을 위해 사용하였던 Risk Grade 방정식에 시간 항(time term)과 도심지의 최초 침수 발생위치에 생성 항(source term)을 추가하여 도심지 침수특성을 반영하였다. 결과를 평가하기 위하여 CRITIC(CRiteria Importance Through Intercriteria Correlation) 방법을 활용한 형상유사도를 산출하였다. 그 결과, 기 구축된 홍수위험지도와 형상유사도는 전체 구역 중 80%의 구역이 0.8 이상의 값을 나타내었다. 20%의 구역에서는 복잡한 도심지의 건물, 구조물 등의 침수특성을 반영하지 못하여 형상유사도가 낮게 평가된 것으로 판단되며, 향후 위험도 예측을 위해 배수시스템 등의 영향인자를 고려한다면 위험도 등급 예측의 정확도를 높일 수 있을 것이라 기대된다.

  • PDF