• Title/Summary/Keyword: 대피 층

Search Result 54, Processing Time 0.022 seconds

A study on building evacuation simulation using Floor Field Model (Floor Field Model을 이용한 건축물의 대피시뮬레이션에 대한 연구)

  • Nam, Hyunwoo;Kwak, Suyeong;Jun, Chulmin
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.2
    • /
    • pp.1-11
    • /
    • 2016
  • The floor field model (hereafter referred to as FFM) is a cellular automata (hereafter referred to as CA)-based walk model used to model pedestrian behavior. Existing studies on FFM conducted experiments with simple structures (that have one room or one obstacle in a room) or relatively complicated structures (that have many rooms). In order to apply the FFM to real buildings, it is necessary to have additional methodologies to process information about the number of rooms, floors, stairs, and exit doors. In particular, it is necessary to process exit doors during this procedure. Exit doors that are recognized by pedestrians are of many types such as exit doors in rooms, stairs connected to corridors, and exit doors in a building. When calculating the static floor field (hereafter referred to as SFF) in the FFM, information about exit doors is needed and simulation results will be different depending on how the SFF is calculated using an exit door among the above-mentioned exit doors. In this study, an XML-format building data model is proposed according to data structures required by the FFM. This study also defines a methodology to process a number of exit doors. Accordingly, this study developed a building data construction and evacuation simulator and simulation experiments were conducted with university campus building.

Development of Urban Flood Forecasting Model using Statistical Method (통계학적 기법을 이용한 도시홍수 예.경보모형의 개발)

  • Lee, Beum-Hee;Lim, Jong-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.805-809
    • /
    • 2007
  • 최근 도시의 발달은 하상공간에 대한 이용도를 높이는 방향으로 개발이 진행되어가는 추세이며, 하상도로 및 하상주차장의 이용은 이제 도시 내에서 이용 가능한 마지막 여유 공간으로 인식될 정도로 그 의존도가 높아져가고 있다. 그러나 하상공간의 활용도가 높아져갈수록 도시홍수의 발생으로 인한 대피문제가 발생하게 되고 돌발홍수로 인하여 하상도로의 차단 혹은 하상 주차장에 주차된 차량의 소거가 늦어지는 경우 고스란히 피해를 보게 되는 등 그 부작용도 계속 증가되고 있다. 도시홍수의 특성을 살펴보면 국지성 돌발 강우에 의한 유량의 급격한 증가와 짧은 유하시간, 작은 유역면적 등에 의하여 주요 예보지점까지의 도달시간이 매우 짧아 수문학적 홍수예측 모형을 이용하여 홍수예측 업무를 수행하는데 선행시간을 충분히 확보할 수 없다는 단점을 지니고 있다. 이에 따라 본 연구에서는 기존의 하천시스템에 대한 설계 등을 목적으로 하여 모형의 적용을 통한 시뮬레이션 기법을 적용하고 이를 통하여 홍수 예경보를 발령하기에는 선행시간의 확보(대피시간의 확보)라는 측면에서 상당한 어려움을 지닐 수 있으므로 시시각각으로 측정되는 실시간 수위측정 자료 및 실시간 강우자료를 이용하여 모형의 수행과정을 생략하고 하천의 수위변동을 직접 예측하고 대피할 수 있는 시나리오 기반의 수문모형을 개발하였다. SPSS를 사용한 통계학적 모형을 대전광역시 3대 하천에 대하여 적용한 결과 예측자료가 실측자료를 고수위 및 저수위 부근에서 정확히 모의하지 못하는 경향이 나타났으나 경계 및 위험수위를 설정하고 이를 넘어가는 시점에 대한 예측을 하는 홍수경보 시점 예측에는 효율적인 적용성을 나타내었다.씬 간편하면서도 정확도가 높아서, 환경방사성 스트론튬의 정량분석에 적절히 사용될 수 있다.e form of Jones matrix, which allows a new interpretation in the conversion efficiency of the thin-film optical waveguides.있다는 장점이 있었다. 따라서 소아에서 복막투석도관 수술 시 복강경적 방법을 이용하는 것이 효율적인 복막 투석을 위해 유용하다고 생각된다.상부 방광천자에 비해 민감도 59.5%(25/42), 특이도 86.6%(13/15)였고 위양성률 13.3%(2/15), 위음성률 40.5%(17/42) 로 정확도가 낮았다. 결론 : 소변을 가리지 못하는 영유아에서 요로 감염을 진단하기 위해서는 도뇨관 채뇨에 비해 초음파 감시하 치골상부 방광천자가 정확하고 안전한 채뇨법으로 권장되어야 한다고 생각한다.應裝置) 및 운용(運用)에 별다른 어려움이 없고, 내열성(耐熱性)이 강(强)하므로 쉬운 조건하(條件下)에서 경제적(經濟的)으로 공업적(工業的) 이용(利用)에 유리(有利)하다고 판단(判斷)되어진다.reatinine은 함량이 적었다. 관능검사결과(官能檢査結果) 자가소화(自家消化)시킨 크릴간장은 효소(酵素)처리한 것이나 재래식 콩간장에 비하여 품질 면에서 손색이 없고 저장성(貯藏性)이 좋은 크릴간장을 제조(製造)할 수 있다는 결론을 얻었다.이 있음을 확인할 수 있었다.에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며,

  • PDF

A Study on Integrated Fire Protection System for high-rise Building (초고층빌딩 통합 화재방재시스템 설계 및 구현에 관한 연구)

  • Lee, Jeong-Bae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.39-47
    • /
    • 2020
  • The fire protection system for high-rise buildings is currently confined to the preparation of sprinklers, emergency stairs, and exit and monitoring systems. On the other hand, an integrated system, including the model with scenario-based actions, is required for effective fire protection. An integrated fire protection system is needed to operate and manage the total cycle of the fire protection. In this study, an integrated fire protection system, which included sensing and consequent processes related to fire emergencies, was designed and implemented. The designed scheme can gather and analyze the data of the production, operation, and consumption patterns as it integrates fire protection systems for fire fighters and evacuating people. The integrated fire protection technology and system, which has target performance with satisfied 1/2 sec transaction response time and 1.2 transactions per second, is expected to contribute to market creation in converged technology-based fire protection fields.

Analysis of A Gas Explosion-Related State Compensation Case (가스폭발 사고와 관련된 국가배상 사례의 분석)

  • Lee, Euipyeong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.44-59
    • /
    • 2020
  • This study analyzed a gas explosion accident. A gas smell from a underground coffee shop in the two-story building was reported to 119. A fire brigade was turned out, turned off the main valve of LPG gas cylinder on the roof, and checked the turning off of middle valve in the coffee shop. The fire brigade required a gas supplier and gas installer who arrived at the spot to take safety actions. Gas explosion occurred seven minutes after the fire brigade was withdrawn and two people died and 21 people were injured. A court decided that because the causes for gas explosion were not found, compensation responsibility could not be charged with the gas supplier, the gas installer, or Korea Gas Safety Corporation. In this reason, the court judged that only the fire brigade who was withdrawn without taking safety actions shall compensate victims or bereaved families. Therefore, fire brigades who turn out after a 119 report of a gas leak should take safety actions such as escaping people or preventing people's access and ventilating and be withdrawn when there is no possibility of fire or explosion.

The Korea Academia-Industrial cooperation Society (유리섬유 복합재료를 이용한 화재 비상통로용 스크린 소재 성능에 관한 연구)

  • Lee, Jung-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.653-659
    • /
    • 2018
  • High-rise buildings and complex facilities are a representative urban system for the masses, and it requires an increasing role of commodity and safety. Smoke and toxic gasses can cause accidents due to fire in these systems. The purpose of this study is to develop a fiber screen material for emergency evacuation passages that can be avoided quickly and safely in cases of disasters. The fiber screen material is applicable to folding devices for emergency evacuation passages. The material is different from general steel material in that it is lightweight with less burden during storage for a long time in a roll form in a folding device. It also has an excellent secondary function in that it is less affected by radiant heat. Three kinds of fiber screen materials were selected that have good flame retardancy and post-processing characteristics. A performance evaluation was performed by a heat shrinkage test, contact heat test, combustibility test, flame retardancy test, tensile strength test, and tear strength test. As a result, the lightweight fabric shows excellent performance through post-processing, and silicone resin coating can secure safety of the pizza by the fiber screen material performance and radiant heat. The optimum post-treatment conditions were evaluated by performing a burning test after coating two kinds of glass fibers and four types of flame-retardant silicone resins with different weight and thickness.

Study on the non-point source control and treatment by vegetation zone (식생대에 따른 비점오염원 관리 및 처리 연구)

  • Choi, I-Song;Kim, Sung-Won;Kim, Soeg-Ku;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.483-487
    • /
    • 2006
  • 본 연구는 비점오염원에 의한 수질오염현상을 억제하기 위한 수변지역의 관리기법 중 하나인 식생여과대를 효과적으로 설치하기 위하여 식생에 의한 오염물질의 저감능력을 파악하고 효율적 설치방안을 모색하기 위하여 수행되었다. 연구결과 T-N과 T-P의 깊이별 오염물질 저감효과는 나대지에서 표면유출이 각각 17.6%, -23.9%, 단면유출이 각각 51.7%, 91.0%, 하부유출이 각각 38.4%, 89.3%인 것으로 나타나 표면층을 통한 유출보다는 토양층에 침투될수록 오염물질의 저감효과가 높아지는 것으로 나타났다. 잔디로 표면층을 식재한 실험에서는 표면, 단면, 하부유출에서의 T-N이 각각 16.0%, 57.1%, 38.4%의 오염물질 저감효과를 보였고, T-P의 저감효과는 각각 -9.7%, 83.6%, 88.8%인 것으로 조사되었다. 또한 돌미나리로 표면층을 식재한 실험에서는 표면, 단면, 하부유출에서의 T-N 처리효율이 각각 -2.6%, 62.1%, 71.2%로 나타났으며, T-P는 각각 -7.2%, 94.5%, 84.5%인 것으로 조사되었다. 결론적으로 식생을 한 경우 전체적으로 오염물질의 저감효율이 비교적 안정되게 유지되는 것으로 나타났으나, T-P의 표면층을 제외하면 전체적인 저감효과에 크게 영향을 미치지 않은 것으로 판단된다. 그러나 일반적으로 알려져 있는 식생에 따른 오염물 저감효과에 대한 순기능 즉 토양입자의 침식방지, 토양용액의 저류작용 및 공극확대에 따른 침투능력 증대, 토성의 개량 등과 같은 기능을 무시할 수 없으므로 오염저감효과를 극대화하기 위해서는 처리대상이 되는 하천유역의 자생적 식생을 보다 효과적으로 활용할 수 있는 방안마련이 비용적 측면이나 생태 보존적 측면에서 유리할 것으로 판단된다.one)을 설치하는 대책이 필요하다. 저수지 관리를 효과적으로 수행하기 위해서는 저수지 내부의 탁도 거동을 정확히 예측할 수 있어야 한다. 따라서 추후 동수역학 및 열역학에 기초한 3차원 수치모형 연구와 성층흐름에 정밀한 밀도류 실험연구 및 이에 대한 적용이 필요할 것으로 판단된다.함으로써 정보의 질적보장과 정보전환의 표준화방안을 제시하는 정보분석시스템이다.이용, 수자원의 지속적 확보기술의 특성에 따른 4개의 평가기준과 26개의 평가속성으로 이루어진 2단계 기술가치평가 모형을 구축하였으며 2개의 개별기술에 대한 시범적용을 실행하였다.하는 것으로 추정되었다.면으로의 월류량을 산정하고 유입된 지표유량에 대해서 배수시스템에서의 흐름해석을 수행하였다. 그리고, 침수해석을 위해서는 2차원 침수해석을 위한 DEM기반 침수해석모형을 개발하였고, 건물의 영향을 고려할 수 있도록 구성하였다. 본 연구결과 지표류 유출 해석의 물리적 특성을 잘 반영하며, 도시지역의 복잡한 배수시스템 해석모형과 지표범람 모형을 통합한 모형 개발로 인해 더욱 정교한 도시지역에서의 홍수 범람 해석을 실시할 수 있을 것으로 판단된다. 본 모형의 개발로 침수상황의 시간별 진행과정을 분석함으로써 도시홍수에 대한 침수위험 지점 파악 및 주민대피지도 구축 등에 활용될 수 있을 것으로 판단된다. 있을 것으로 판단되었다.4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.게 이루어질 수 있을 것으로 기대된다.는 초과수익률이 상승하지만, 이후로는 감소하므로, 반전거래전략을 활용하는 경우 주식투자기간은 24개월이하의 중단기가 적합함을 발견하였

  • PDF

Vertical Evacuation Speed in Stairwell of a High-rise Office Building (업무용 고층건물 계단실의 보행속도에 관한 연구)

  • Joung, Suck-Hwan;Yoon, Myong-Oh
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.13-20
    • /
    • 2015
  • As building height is increased, more careful decisions about the required safe egress time is needed for evacuation. This study analyzed the influence of three training sessions on the vertical speed of evacuation in the high rise building. Evacuation experiments were done in a high-rise office building in Seoul, and we analyzed the vertical evacuation speed as a function of density using a camera. Controlled and uncontrolled total evacuation were compared using the Pathfinder simulation. The process of repeated training, changed the specific stair utilization rate from 6.3% to 39.5%. The vertical evacuation speed as a function of density was analyzed using the equation s = 1.004 ? 0.288D, which is very similar to the equation used in a different study. The total evacuation time of the special controlled total evacuation was reduced by about 25% compared to the simultaneous evacuation.

A Study on the Analysis of Fire Risk by Fire and the Improvement of Evacuation Equipment for Apartment (About Existing 16 or Fewer Storey Apartment) (공동주택의 화재위험성 분석 및 피난시설 개선에 관한 연구 (16층 이하의 기존 공동주택을 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon;Sa, Jae-Cheon;Nam, Jung-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.127-135
    • /
    • 2011
  • In this study, we assumed the kitchen fire raising the highest fire rate in apt. and analyzed the fire risk to use CFD in order to estimate the problem of evacuation equipment and the fire vulnerability of 16 or fewer storey apartment. Fire occurring in the kitchen is expended to the livingroom and other rooms. We analyzed that the temperature effected by heat was more than $60^{\circ}C$ after 90 sec in the entrance of apartment unit. If fire is early recognized by men and men don't escape in time, it have too huge demage to block the exit. When the evacuation equipment suggested in this study was installed in order to solve the problem of evacuation equipment, we analyzed that it was estimated more than safe in safety evaluation by heat and heat flux.

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

A Study on the Performance Improvement Plan of Inflowing Air Emission (유입 공기의 배출 성능 개선방안에 관한 연구)

  • Lee, Hye-Young
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.2
    • /
    • pp.241-251
    • /
    • 2022
  • Purpose: In the event of a fire in a high-rise building, if the smoke control area is not effectively protected, smoke or flames enter the stairwell, making it difficult to evacuate. When inflowing air is discharged from a closed corridor, a negative pressure is formed in the corridor, the pressure in the smoke control area becomes excessively high, and the force required to open the door during evacuation is exceeded. Also, if the air introduced into the hallway is not exhausted, the smoke may flow back into the smoke control area. This paper tried to identify the problems caused by the inflowing air and to find out how to improve the performance. Method: Using the CONTAM program, simulations were performed with the basic conditions and the modified conditions. Result: If the inflowing air was discharged from the sealed corridor, overpressure occurred in the Smoke Control Area and exceeded the opening force, and the prevent smoke backflow was insufficient in the layer where the inflowing air was not discharged. Conclusion: "Differential pressure exhaust damper" application, simultaneous opening of two exhaust dampers, and automatic window installation between corridors and outdoors improved the exhaust performance of inflowing air.