• Title/Summary/Keyword: 대피인원

Search Result 41, Processing Time 0.027 seconds

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

A Study on the Indoor Evacuation Using Matsim (활동기반 교통모형 MATSim을 이용한 실내 피난 분석)

  • Kim, Joo young;Lee, Seung jae;Ahn, Chi won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.2
    • /
    • pp.18-31
    • /
    • 2018
  • It is important to conduct various analyzes to evacuate occupants in advance, because the disaster can cause serious injury. Therefore, it is necessary to analyze all the predictable scenarios that may occur. In this study, we propose a method to analyze the evacuation of indoor disaster using activity - based transport model MATSim. We have developed the university building as target area and simulated about 5,000 occupants. The analysis scenarios are set as basic evacuation conditions, exit closures and emergency stair closures. As a result of analysis of each scenario, the evacuation time was analyzed to be about 5:40(340s) in the base scenario, increased by 15% in the scenario 2 and increased by 23% in scenario 3. As a result of this study, we suggest that it is important to manage illegal obstacles of emergency stairs for rapid evacuation. Therefore, this study can contribute to the effective disaster prevention strategy of the building.

The Case Analysis through Fire Simulation FDS and Evacuation Simulation Pathfinder (화재 시뮬레이션 FDS와 피난시뮬레이션 Pathfinder 사례분석)

  • Kim, Jong Yoon;Jeon, Yong Han
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.6
    • /
    • pp.253-260
    • /
    • 2015
  • In this study, using the FDS as the fire simulation and evacuation simulations of the Pathfinder, set the main control room of the building to the fire point fire safety assessment studies were carried out. At first the quantitative result such as distribution of visibility as time passing, distribution of temperature, distribution of CO density produced results using fire-simulation and evacuation-simulation was carried out based on the result that produced the final safety evaluation result as being calculated of evacuation time. As the risk increased with the distribution of visibility at the result of fire-simulation, evacuation-simulation was carried out using the result. Finally the result was made 127.9 sec that everyone could evacuate. The numerical results are analyzed in case of the places in the building required safe egress time for safety a as the analysis to be no more than available safe egress time was analyzed to be secured. The results of this safety evaluation represent that more smooth evacuation safety performance can be secured by linking the event of fire firefighting equipment as a result of simulating the worst conditions.

  • PDF

A Study on the Conceptual Design of Quay Process Monitoring System (안벽공정 모니터링 시스템의 개념 설계에 관한 연구)

  • Kim, Ho-Kyeong;Ko, Dae-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.426-431
    • /
    • 2016
  • In quay processes in shipyards, it is difficult to manage workers and to maintain secure working environments because at least 1,000 people can occupy the quay at the same time. In this study, a system was designed to monitor the environment and processes of quay operation. In order to lower initial investments and the costs of maintenance and operation, the entire system consists of six connected components. Considering the communication environment of the shipyard site, Wi-Fi and the LoRa communication protocol were selected for the system. The feasibility of the communication protocols was verified by data transmission tests in the field. The designed system can provide real-time information about employees working in the quay area, the safety status of moored ships on the quay, and step-by-step alarms in dangerous situations based on the detected information. The system is expected to prevent or greatly reduce safety hazards.

Fire and Evacuation Simulation Analysis of Large-Scale Domestic Data Centers (국내 대규모 데이터센터 화재 및 피난 시뮬레이션 분석 )

  • Kim, Dong-Min;Go, Eun-Seong;Park, Hyeong-Gyoon;Gwak, Ji-Hyeon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.347-348
    • /
    • 2023
  • 본 논문에서는 실제 규모 데이터센터의 3D 모델링을 기반으로 대상 공간별 화재 시나리오를 선정하여 화재 및 피난 시뮬레이션을 수행하였다. FDS와 Pathfinder는 full coupling 방식을 사용할 수 없는 한계가 있으며 semi coupling의 경우 가시화에는 도움이 되나 결과에 영향을 주지 않는다. 따라서 재실자의 피난 상황 시 경로에 대한 안전성과 화재 위험 노출 정도를 시각적으로 분석하는 것이 가능한 semi coupling과 시뮬레이션 결과 데이터 분석을 병행하여 수행하였다. 전산실의 경우 서버의 기능상실 한계 온도가 32도이기 때문에 서버 기능 정지 상황에 도달하는 시간을 중점적으로 분석하였다. 전산실은 업무 및 고객 서비스와 관련된 모든 데이터들을 저장하기 위해 항시 기동 되어야 하는데 전산실 내 화재가 발생할 경우 1~2분 이내 서버 기능이 정지되는 상황이 발생하였다. 따라서, 서버가 안전하게 계속 동작하기 위해서는 전력 계측 및 제어 케이블 열화, 서버 장치의 건전성이 유지되어야 하며 초기 화재를 빠르게 감지하여 진압하여야 한다. 피난 시뮬레이션의 경우 가시도를 상실하게 되는 시간이 약 195초(5m 미만) 인근으로 인원이 해당 층을 완전히 벗어나는 데 걸리는 시간이 약 125.6초였던 것을 보면 대피하기에 충분한 허용 피난시간(ASET)을 확보하고 있음을 알 수 있었다.

  • PDF

The Study of Outflow Rate of Stair and Turnstile in Subway Station - Comparison between Measurement and Simulation (지하철 역사에서 개찰구 및 계단 유출특성에 관한 연구 - 실측과 시뮬레이션의 비교)

  • Kim, Eung-Sik;Cho, Ju-Ho;Kim, Myeoung-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • Recently commercial egress softwares are frequently used for the risk assessment. The estimation of evacuation time is an important procedure and the outflow coefficient in a bottleneck becomes the crucial factor for design of emergency planning. This paper compares the outflow coefficient of measurement with those of softwares in the bottlenecks of subway stations where masses of people movement is observed. Stairway and turnstile are the 2 bottleneck points along escape pathway. For the escape simulation it is recommended that 2 different modes be used in the programs for 2 kinds of bottleneck. The results of the comparison makes a big difference among them and some of differences can be reduced by correct design of input data. In conclusion the results of simulation should be examined thoroughly by procedure of comparisons with other results.

A Study on the Necessity of Introducing Evacuation Instrument in High-rise Buildings - Focusing on Elevator Type Evacuation Instrument - (고층건축물의 피난기구 도입 필요성에 관한 연구 - 승강식피난기를 중심으로 -)

  • Choi, Kyu-Chool;Ra, Pan-Ju;Seul, Yeong-Mi
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.10-19
    • /
    • 2014
  • The fast evacuation from fire floors to evacuation floors in high-rise building fires can minimize the human damage. In this study, an evacuation instrument, which are applicable to the high-rise buildings of adaptable escape mechanisms by the current NFSC 301 (national fire safety code 301), were selected to analyze the applicability in the high-rise buildings over 11th floor through the site adaptability test. The results of the site test were as follows. The elevator type evacuation instrument of new concept developed as a new technology by compensating the defect of evacuation instrument limiting in the high-rise buildings over 11th floor had completed the stability test and the performance certification test in fire stations, which there were no problems in the introduction of the elevator type evacuation instrument as an escape mechanism in the high-rise buildings. The elevator type evacuation instrument using escapers' weight without using electric power was an escape mechanism that many people could evacuate in a short period of time when a fire broke out in the high-rise buildings. In particular, The elevator type evacuation instrument operated by nonpower had the adaptability as a customized escape mechanism considering user characteristics in the buildings for the disabled or patients with an advanced disease.

Effects of evacuation delay time and fire growth curve on quantitative risk for railway tunnel fire (철도터널 화재 시 피난개시시간지연 및 화재성장곡선이 정량적 위험도에 미치는 영향)

  • Ryu, Ji-Oh;Kim, Hyo-Gyu;Lee, Hoo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.809-822
    • /
    • 2018
  • A quantitative risk assessment has been introduced to quantitatively evaluate fire risk as a means of performance based fire protection design in the design of railway tunnel disaster prevention facilities. However, there are insufficient studies to examine the effect of various risk factors on the risk. Therefore, in this study, the risk assessment was conducted on the model tunnel in order to examine the effects of the evacuation start time delay and the fire growth curve on the quantitative risk assessment. As a result of the analysis of the scenario, the fatalities occurred mainly when escapes in the same direction as the direction of the fire smoke movement. In addition, after the FED exceeded 0.3, the maximum fatalities occurred within 10 minutes. In the range of relatively low risk, distance between cross passages, evacuation delay time and fire growth curve were found to affect the risk, but they were found to have little effect on the condition that the risk reached the limit. Especially, in this study, it was evaluated that the evacuation delay time reduction, fire intensity and duration reduction effect were not observed when the distance between cross passages was more than 1500 m.

Shelter location-allocation for Tsunami Using Floating Population and Genetic Algorithm (유동인구 데이터와 유전자 알고리즘을 이용한 지진해일 대피소 선정)

  • Bae, Junsu;Kim, Mi-Kyeong;Yoo, Suhong;Heo, Joon;Sohn, Hong-Gyoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.3
    • /
    • pp.157-165
    • /
    • 2019
  • Recently, large and small earthquakes have occurred in the Korean peninsula. In this sense, Korea is no longer considered as an earthquake free zone. Especially, it is necessary to respond quickly to earthquake tsunami which may be caused by the influence of neighboring countries with large earthquakes. Since the occurrence of tsunamis can cause great casualties, it is very important to allocate the location of the shelter in case of an earthquake. Although many researches on shelter allocation have been conducted in various ways, but most of them have been analyzed based on administrative district resident data, resulting in a lack of reality. In this study, floating population data were used to reflect reality in case of emergency situations, and genetic algorithm, which produce good results among the heuristic algorithms, was used to select shelter locations. The number of evacuees was used as a objective function of genetic algorithm and the optimal solution was found through selection, crossover and mutation. As a result of the research on Busan Haeundae-Gu, selected as a research area, allocating eight shelters was the most efficient. The location of the new shelters was selected not only in residential areas but also in major tourist areas whose results can not be derived from administrative district resident data alone, and the importance of utilizing the floating population data was confirmed through this study.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.