• Title/Summary/Keyword: 대역정제

Search Result 17, Processing Time 0.016 seconds

Modified One-Bit Transform Motion Estimation Algorithm based on the Wavelet Transform (웨이블릿 변환을 이용한 보완된 이진 블록 정합 움직임 예측 알고리듬)

  • Yoo, Kun-Ho;Lee, Hyuk;Jong, Je-Chang
    • Journal of Broadcast Engineering
    • /
    • v.15 no.3
    • /
    • pp.355-361
    • /
    • 2010
  • Video Compression is the key technology for the transmission of multi-media data. Because the Motion Estimation is the most complex module in the video compression, fast motion estimation algorithm is essential for the real-time application. In this paper, we propose an enhanced binary motion estimation algorithm based on the wavelet transform. Proposed algorithm improve the quality of coded video.

An Improved Guided Image Filtering Technique based on Sobel Operator for Removing Gaussian Noise (가우시안 잡음 제거를 위한 소벨 연산자 기반의 개선된 가이디드 이미지 필터링 기법)

  • Song, Seongmin;Choi, Hyunho;Jeong, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2018.11a
    • /
    • pp.104-107
    • /
    • 2018
  • 최근 촬영 기기의 기술발전으로 인해 디지털 영상의 해상도가 증가함에 따라 선명한 디지털 영상에 대한 요구가 증가하고 있다. 이러한 요구에도 불구하고 디지털 영상 내 가우시안 잡음 (gaussian noise)은 촬영기기를 통해 영상 획득 및 처리 과정에서 발생하여 화질을 열화 시킨다. 디지털 이미지에서 발생하는 가우시안 잡음을 제거하기 위해서 기존의 저대역 통과 필터 (low-pass filter: LPF)를 사용하면 잡음은 제거되지만, 블러링 현상 (blurring phenomenon)이 나타난다. 이러한 문제점을 개선하기 위해 소벨 연산자 (sobel operator)를 사용하여 영상 내 에지 맵 (edge-map)을 생성하여 에지 영역과 동질 영역을 구분한다. 에지영역에서는 약한 저역 필터 (weak low-pass filter)를 사용하고, 그 외의 이미지 영역에서는 강한 저역 필터 (strong low-pass filter)를 사용하는 알고리듬을 제안하였다. 그리고 다양한 이미지에 대하여 기존 알고리듬과 제안한 알고리듬의 적용한 결과를 통해 주관적 화질 비교하였고 객관적 지표로 최대 신호 대 잡음비 (peak signal-to noise ratio: PSNR)와 구조 유사성 (structural similarity: SSIM)을 사용하여 성능을 평가하였다. 실험결과를 통해 제안된 알고리듬이 잡음 제거 및 외곽선 보존의 우수함을 확인하였다.

  • PDF

Studies on the Separation and Discrimination of the Natural Yellow Pigment on Croaker (참조기 천연색소의 분리 및 판별법에 관한 연구)

  • Kim, Hee-Yun;Hong, Ki-Hyung;Hong, Jin-Hwan;Kim, Dong-Sul;Han, Sang-Bae;Lee, Eun-Ju;Lee, Jeung-Seung;Kang, Kil-Jin;Chung, Hyung-Wook;Song, Kyung-Hee;Park, Jong-Seok;Kwon, Yong-Kwan;Jang, Young-Mi;Shin, Il-Shik;Lee, Chang-Kook;Park, Hee-Yul;Ha, Sang-Chul;Jo, Jae-Sun;Park, Hye-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.762-769
    • /
    • 2002
  • As a preliminary test for defining intact yellow croaker pigment, the pigment was analyzed by column chromatography and UV-vis spectrophotometry. All maximum absorbance wavelengths commonly showed three maximum absorbance ranges, similar to those of carotenoid, suggesting that the tested pigment may be carotenoid. We detected total six peak RT values in the chromatogram through PDA-HPLC under gradient mode (behavior A at 10% for initial 2 min and changed to behavior B for 60 min). Most pigments were detected at the peak with 3.27 RT value. Because seven peaks were detected under gradient mode and three under isocratic mode [methanol : methylene chloride (90 : 10, v/v)], gradient mode was determined to be more appropriate for quantitative analysis. By the comparison test of RT values among yellow pigment in croakers and reference pigments, such as zeaxanthine, ${\beta}-cryptoxanthine$, ${\beta}-carotene$, and astaxanthin, only ${\beta}-cryptoxanthine$ was detected in the white croaker, whereas such pigment of yellow croaker having RT value of 31.02 was not detected. Therefore, RT value was found to be applicable for detecting adulterated croaker.

The Design of Elliptic Function Bandpass Filter using Ceramic Coaxial Resonators (유전체 동축 공진기를 이용한 타원 함수 대역 통과 여파기의 설계)

  • 김정제;윤상원
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.805-814
    • /
    • 1999
  • In this paper, elliptic function bandpass filters using ceramic coaxial resonators are designed. Since elliptic function filters have better performance of frequency selectivity than those based on Butterworth or Chebyshev, therefore it is possible to make better use of limited frequency resources. Elliptic function bandpass filters using ceramic coaxial resonators are designed for reducing it's size, weight, cost and for easy manufacturing and tuning. From measurements, an accurate resonator model is obtained and the coupling coefficient values are extracted. Based on these results, elliptic function bandpass filters are designed. The experimental results have shown that the 8th order elliptic function filter of 959 MHz center frequency with 28 MHz bandwidth using coaxial ceramic resonators have about more tan 17 dB return loss, 5 dB insertion loss, more than 20 dB attenuation at $f_c\pm$5 MHz.

  • PDF

Construction of the Terminology Dictionary for National R&D Information Utilization (국가R&D정보활용을 위한 전문용어사전 구축)

  • Kim, Tae-Hyun;Yang, Myung-Seok;Choi, Kwang-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.217-225
    • /
    • 2019
  • National research and development(R&D) information is information generated in the process of performing R&D based on programs and projects issued by national government departments, and includes information from various research fields as ordered by various departments. Therefore, for efficient R&D information retrieval, it is necessary to build a national R&D terminology dictionary that can reflect the characteristics of such national R&D information. In this study, we propose a method for constructing a national R&D terminology dictionary by applying the classification of science and technology standards used to specify the research field in national R&D information. We will discuss the structural characteristics of national R&D project information and the usefulness of the project keyword, and explain the status of national R&D information by the National Standard Science and Technology Classification(NSSTC) Codes and the characteristics of the national R&D terminologies. Based on this, a method for building a national R&D terminology dictionary is defined in terms of the type and structure of the terminology dictionary, preliminary construction procedures, and refining rules. The national R&D terminology dictionary built on the basis of this study can be used in various ways such as expansion of search terms using Korean-English equivalent words and synonyms when searching national R&D information, clarifying the scope of search using NSSTC, and providing user convenience functions using term explanation information.

A research on the emotion classification and precision improvement of EEG(Electroencephalogram) data using machine learning algorithm (기계학습 알고리즘에 기반한 뇌파 데이터의 감정분류 및 정확도 향상에 관한 연구)

  • Lee, Hyunju;Shin, Dongil;Shin, Dongkyoo
    • Journal of Internet Computing and Services
    • /
    • v.20 no.5
    • /
    • pp.27-36
    • /
    • 2019
  • In this study, experiments on the improvement of the emotion classification, analysis and accuracy of EEG data were proceeded, which applied DEAP (a Database for Emotion Analysis using Physiological signals) dataset. In the experiment, total 32 of EEG channel data measured from 32 of subjects were applied. In pre-processing step, 256Hz sampling tasks of the EEG data were conducted, each wave range of the frequency (Hz); Theta, Slow-alpha, Alpha, Beta and Gamma were then extracted by using Finite Impulse Response Filter. After the extracted data were classified through Time-frequency transform, the data were purified through Independent Component Analysis to delete artifacts. The purified data were converted into CSV file format in order to conduct experiments of Machine learning algorithm and Arousal-Valence plane was used in the criteria of the emotion classification. The emotions were categorized into three-sections; 'Positive', 'Negative' and 'Neutral' meaning the tranquil (neutral) emotional condition. Data of 'Neutral' condition were classified by using Cz(Central zero) channel configured as Reference channel. To enhance the accuracy ratio, the experiment was performed by applying the attributes selected by ASC(Attribute Selected Classifier). In "Arousal" sector, the accuracy of this study's experiments was higher at "32.48%" than Koelstra's results. And the result of ASC showed higher accuracy at "8.13%" compare to the Liu's results in "Valence". In the experiment of Random Forest Classifier adapting ASC to improve accuracy, the higher accuracy rate at "2.68%" was confirmed than Total mean as the criterion compare to the existing researches.

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.